The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Effect of resolution on the speed and accuracy of particle image velocimetry interrogation
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405 · cited 1×
“Adrian (1991) suggests that for irregular particle images and imperfections arising from film grain, pixel readout noise, etc., the random error should scale with d,:”
BackgroundSelf-citationDigital particle image velocimetry
Willert, C. E., & Gharib, M. (1991) · Experiments in Fluids · doi:10.1007/bf00190388 · Cited by 1,991
Optimization of particle image velocimeters. I. Double pulsed systems
Keane, R. D., & Adrian, R. J. (1990) · Measurement Science and Technology · doi:10.1088/0957-0233/1/11/013 · Cited by 816
Self-citationHigh resolution measurement of turbulent structure in a channel with particle image velocimetry
Liu, Z.-C., Landreth, C. C., Adrian, R. J., & Hanratty, T. J. (1991) · Experiments in Fluids · doi:10.1007/bf00190246 · Cited by 131
Self-citation
Cited by
Vortex organization in the outer region of the turbulent boundary layer
ADRIAN, R. J., MEINHART, C. D., & TOMKINS, C. D. (2000) · Journal of Fluid Mechanics · doi:10.1017/s0022112000001580 · Cited by 1,709
Self-citationFundamentals of digital particle image velocimetry
Westerweel, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/002 · Cited by 1,425
Iterative image deformation methods in PIV
Scarano, F. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/1/201 · Cited by 842
PIV measurements of a microchannel flow
Meinhart, C. D., Wereley, S. T., & Santiago, J. G. (1999) · Experiments in Fluids · doi:10.1007/s003480050366 · Cited by 802
Distortion compensation for generalized stereoscopic particle image velocimetry
Soloff, S. M., Adrian, R. J., & Liu, Z.-C. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/008 · Cited by 674
Self-citationSpanwise structure and scale growth in turbulent boundary layers
TOMKINS, C. D., & ADRIAN, R. J. (2003) · Journal of Fluid Mechanics · doi:10.1017/s0022112003005251 · Cited by 599
Self-citationWesterweel, J., Dabiri, D., & Gharib, M. (1997) · Experiments in Fluids · doi:10.1007/s003480050082 · Cited by 476
A hybrid digital particle tracking velocimetry technique
Cowen, E. A., Monismith, S. G., Cowen, E. A., & Monismith, S. G. (1997) · Experiments in Fluids · doi:10.1007/s003480050038 · Cited by 387
Dynamic ranges of velocity and spatial resolution of particle image velocimetry
Adrian, R. J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/003 · Cited by 328
Self-citationLow cost, high resolution DPIV for measurement of turbulent fluid flow
Fincham, A. M., & Spedding, G. R. (1997) · Experiments in Fluids · doi:10.1007/s003480050135 · Cited by 292
Uncertainty quantification in particle image velocimetry
Sciacchitano, A. (2019) · Measurement Science and Technology · doi:10.1088/1361-6501/ab1db8 · Cited by 268
Scheimpflug stereocamera for particle image velocimetry in liquid flows
Prasad, A. K., & Jensen, K. (1995) · Applied Optics · doi:10.1364/ao.34.007092 · Cited by 264
Self-citationAirflow assessment in cross-ventilated buildings with operable façade elements
Karava, P., Stathopoulos, T., & Athienitis, A. K. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.07.022 · Cited by 261
Three-dimensional particle image velocimetry: error analysis of stereoscopic techniques
Lawson, N. J., & Wu, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/8/010 · Cited by 125
Metadata
- Authors
- Prasad, A. K., Adrian, R. J., Landreth, C. C., & Offutt, P. W.
- Venue
- Experiments in Fluids
- Published
- 1992-06
- Volume
- 13
- Issue
- 2-3
- Pages
- 105-116
- ISSN
- 0723-4864 (ISSN-L)
- 1432-1114
- OpenAlex
- W2071285068
- Cited by
- 493
- References
- 4
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.