The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
The extracellular patch clamp: A method for resolving currents through individual open channels in biological membranes
Open accessAbstract
The current contributions of individual ionic channels can be measured by electrically isolating a small patch of membrane. To do this, the tip of a small pipette is brought into close contact with an enzymatically cleaned membrane of a hypersensitive amphibian or mammalian muscle fiber. Current flowing through the pipette is measured. If the pipette contains cholinergic agonist at μ-molar concentrations, square pulse current waveforms can be observed which represent the activation of individual acetylcholine-receptor channels. The square pulses have amplitudes of 1 to 3 pA and durations of 10–100 ms.In order to obtain the necessary resolution, a delicate compromise had to be found between different experimental parameters. Pipettes with 1–3 μm internal diameter and a steep final taper had to be used, extensive enzyme treatment was necessary, and conditions had to be found in which channels open at a relatively low frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single-channel currents recorded from membrane of denervated frog muscle fibres
NEHER, E., & SAKMANN, B. (1976) · Nature · doi:10.1038/260799a0 · Cited by 2,570
Self-citationAnderson, C. R., & Stevens, C. F. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010410 · Cited by 986
The statistical nature of the acetylcholine potential and its molecular components
Katz, B., & Miledi, R. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009918 · Cited by 957
Local anaesthetics transiently block currents through single acetylcholine‐receptor channels.
Neher, E., & Steinbach, J. H. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012267 · Cited by 844
Self-citationIon transfer across lipid membranes in the presence of gramicidin A
Hladky, S. B., & Haydon, D. A. (1972) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(72)90178-2 · Cited by 836
An investigation of spontaneous activity at the neuromuscular junction of the rat
Liley, A. W. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005555 · Cited by 568
The cellular functions of membrane transport
Hoffman, J. F. (1964) · Prentice Hall eBooks · Cited by 359
Noise analysis of drug induced voltage clamp currents in denervated frog muscle fibres.
Neher, E., & Sakmann, B. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011442 · Cited by 224
Self-citationEffects of proteolytic enzymes on function and structure of frog neuromuscular junctions
Betz, W., & Sakmann, B. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010211 · Cited by 210
Self-citationThe characteristics of ‘end‐plate noise’ produced by different depolarizing drugs
Katz, B., & Miledi, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010213 · Cited by 172
Cited by
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Self-citationRegulation of the Voltage Gated K+ Channel Kv1.3 by Recombinant Human Klotho Protein
Almilaji, A., Honisch, S., Liu, G., Elvira, B., Ajay, S. S., Hosseinzadeh, Z., Ahmed, M., Munoz, C., Sopjani, M., & Lang, F. (2014) · Kidney and Blood Pressure Research · doi:10.1159/000368472 · Cited by 5,592
Local anaesthetics transiently block currents through single acetylcholine‐receptor channels.
Neher, E., & Steinbach, J. H. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012267 · Cited by 844
Self-citationThe variance of sodium current fluctuations at the node of Ranvier
Sigworth, F. J. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013426 · Cited by 775
Properties of single calcium‐activated potassium channels in cultured rat muscle
Barrett, J. N., Magleby, K. L., & Pallotta, B. S. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014370 · Cited by 709
Liquid junction potentials and small cell effects in patch-clamp analysis
Barry, P. H., & Lynch, J. W. (1991) · The Journal of Membrane Biology · doi:10.1007/bf01870526 · Cited by 672
Sakmann, B., Patlak, J., & Neher, E. (1980) · Nature · doi:10.1038/286071a0 · Cited by 600
Self-citationNicotinic acetylcholine receptors: From basic science to therapeutics
Hurst, R., Rollema, H., & Bertrand, D. (2013) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2012.08.012 · Cited by 522
Single Na+ channel currents observed in cultured rat muscle cells
Sigworth, F. J., & Neher, E. (1980) · Nature · doi:10.1038/287447a0 · Cited by 461
Self-citationSingle channel recordings of Ca2+-activated K+ currents in rat muscle cell culture
Pallotta, B. S., Magleby, K. L., & Barrett, J. N. (1981) · Nature · doi:10.1038/293471a0 · Cited by 414
Fabrication and Use of Nanometer-Sized Electrodes in Electrochemistry
Penner, R. M., Heben, M. J., Longin, T. L., & Lewis, N. S. (1990) · Science · doi:10.1126/science.250.4984.1118 · Cited by 356
Applications of biological pores in nanomedicine, sensing, and nanoelectronics
Majd, S., Yusko, E. C., Billeh, Y. N., Macrae, M. X., Yang, J., & Mayer, M. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.05.002 · Cited by 327
K channels in T lymphocytes: a patch clamp study using monoclonal antibody adhesion
Matteson, D. R., & Deutsch, C. (1984) · Nature · doi:10.1038/307468a0 · Cited by 314
Benham, C. D., Bolton, T. B., Lang, R. J., & Takewaki, T. (1986) · The Journal of Physiology · doi:10.1113/jphysiol.1986.sp015961 · Cited by 304
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
2 Electrophysiology of Ion Transport in Teleost Intestinal Cells
Loretz, C. A. (1995) · Fish Physiology · doi:10.1016/s1546-5098(08)60241-1 · Cited by 159
Metadata
- Authors
- Neher, E., Sakmann, B., & Steinbach, J. H.
- Venue
- Pfl�gers Archiv European Journal of Physiology
- Published
- 1978-07
- Volume
- 375
- Issue
- 2
- Pages
- 219-228
- ISSN
- 0031-6768 (ISSN-L)
- 1432-2013
- OpenAlex
- W2131445842
- Cited by
- 514
- References
- 11
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.