Effect of a low-carbohydrate diet on plasma and sweat ammonia concentrations during prolonged nonexhausting exercise
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
The purpose of this investigation was to examine the effect of low body glycogen stores on plasma ammonia concentration and sweat ammonia excretion during prolonged, nonexhausting exercise of moderate intensity. On two occasions seven healthy untrained men pedalled on a cycle ergometer for 60 min at 50% of their predetermined maximal O2 uptakes (VO2max) firstly, following 3 days on a normal mixed diet (N-diet) (60% carbohydrates, 25% fat and 15% protein) and secondly, following 3 days on a low-carbohydrate diet (LC-diet) (less than 5% carbohydrates, 50% fat and 45% protein) of equal energy content. Blood was collected from the antecubital vein immediately before, at 30th and at 60th min of exercise. Sweat was collected from the hypogastric region using gauze pads. It was shown that plasma ammonia concentrations after the LC-diet were higher than after the N-diet at both the 30th and 60th min of exercise. Sweat ammonia concentration and total ammonia loss through the sweat were also higher after the LC-diet. The higher ammonia concentrations in plasma and sweat after the LC-diet would seem to indicate an increased ammonia production, which may be related to reduced initial carbohydrate stores.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
(1974) · Elsevier eBooks · doi:10.1016/b978-0-12-091304-6.x5001-0 · Cited by 6,755
Diet, muscle glycogen and physical performance.
Bergström, J., Hermansen, L., Hultman, E., & Saltin, B. (1967) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1967.tb03720.x · Cited by 1,740
Ammonia production in muscle and other tissues: the purine nucleotide cycle.
Lowenstein, J. M. (1972) · Physiological Reviews · doi:10.1152/physrev.1972.52.2.382 · Cited by 693
Effect of initial muscle glycogen levels on protein catabolism during exercise
Lemon, P. W., & Mullin, J. P. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.48.4.624 · Cited by 291
Tricarboxylic acid cycle intermediates in human muscle during prolonged exercise
Sahlin, K., Katz, A., & Broberg, S. (1990) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1990.259.5.c834 · Cited by 273
The effect of different diets and of insulin on the hormonal response to prolonged exercise
GALBO, H., HOLST, J. J., & CHRISTENSEN, N. J. (1979) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1979.tb06438.x · Cited by 252
Carbohydrate supplementation, glycogen depletion, and amino acid metabolism during exercise
Wagenmakers, A. J., Beckers, E. J., Brouns, F., Kuipers, H., Soeters, P. B., van der Vusse, G. J., & Saris, W. H. (1991) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1991.260.6.e883 · Cited by 206
Ammonia metabolism in exercise and fatigue: a review.
Mutch, B. J. C., & Banister, E. W. (1983) · PubMed · Cited by 194
Influence of acidosis on AMP deaminase activity in contracting fast-twitch muscle
Dudley, G. A., & Terjung, R. L. (1985) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1985.248.1.c43 · Cited by 139
Adenine nucleotide and IMP contents of the quadriceps muscle in man after exercise
Sahlin, K., Palmskog, G., & Hultman, E. (1978) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00581301 · Cited by 137
Research works printed but not linked: 2
- Da Fonseca-Wollheim F (1973) Direkte Plasmaammoniakbestimmung ohne Enteiweibung. Z. Klin Chem Klin Biochem 11:426?431.
- Parnas JK (1929) Ammonia formation in muscle and its source. Am J Physiol 90:567?472
Cited by
Central Fatigue: The Serotonin Hypothesis and Beyond
Meeusen, R., Watson, P., Hasegawa, H., Roelands, B., & Piacentini, M. F. (2006) · Sports Medicine · doi:10.2165/00007256-200636100-00006 · Cited by 454
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Ammonia emissions from non-agricultural sources in the UK
Sutton, M. A., Dragosits, U., Tang, Y. S., & Fowler, D. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00362-3 · Cited by 331
Central and Peripheral Fatigue During Resistance Exercise – A Critical Review
Zając, A., Chalimoniuk, M., Gołaś, A., Lngfort, J., & Maszczyk, A. (2015) · Journal of Human Kinetics · doi:10.1515/hukin-2015-0118 · Cited by 161
“…another potent factor that may increase ammonia production during exercise of equal intensity, and it can entail dissociation between lactate and ammonia thresholds in healthy young men, commonly applied indicators for control of the training process (Czarnowski et al. 1995, Langfort et al. 2004).”
BackgroundJasuja, O. P., Toofany, M. A., Singh, G., et al. (2008) · Science & Justice · doi:10.1016/j.scijus.2008.08.001 · Cited by 72
“The amount of perspiration may also vary from person to person and the contents of transferred sweat may vary according to dietary habits of the person [3].”
BackgroundSweat Lactate, Ammonia, and Urea in Rugby Players
Alvear-Ordenes, I., García-López, D., De Paz, J. A., & González-Gallego, J. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830380 · Cited by 67
Optimization of printed sensors to monitor sodium, ammonium, and lactate in sweat
Zamarayeva, A. M., Yamamoto, N. A. D., Toor, A., Payne, M. E., Woods, C., Pister, V. I., Khan, Y., Evans, J. W., & Arias, A. C. (2020) · APL Materials · doi:10.1063/5.0014836 · Cited by 68
Petrelli, M., Shkodra, B., Falco, A., Angeli, M. A. C., Vásquez, S., Scarton, A. M., Pogliaghi, S., Biasi, R., Lugli, P., & Petti, L. (2023) · Organic Electronics · doi:10.1016/j.orgel.2023.106889 · Cited by 30
Tang, Y., Zhong, L., Zhang, Y., Mo, X., Bao, Y., Ma, Y., Wang, W., Han, D., Gan, S., & Niu, L. (2023) · 中国科学通报:英文版 · doi:10.1016/j.scib.2023.10.011 · Cited by 20
Validating sweat ammonia as physiological parameter for wearable devices in sports science
Renner, E., Lang, N. R., Langenstein, B., Struck, M., & Bertsch, T. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175434 · Cited by 23
“Investigations about the behavior of blood and sweat ammonia concentrations during exhausting exercise have been conducted in the early 90s [3-6].”
BackgroundCamerino, S. R. A. E. S., Lima, R. C. P., França, T. C. L., Herculano, E. D. A., Rodrigues, D. S. A., Gouveia, M., Cameron, L. C., & Prado, E. S. (2015) · Food & Function · doi:10.1039/c5fo01054c · Cited by 17
A Review of the Literature on the Application of Blood Ammonia Measurement in Sports Science
Yuan, Y., & Chan, K.-M. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.10608892 · Cited by 15
菅瀬貞治, & Tsuda, T. (2002) · BUNSEKI KAGAKU · doi:10.2116/bunsekikagaku.51.429 · Cited by 15
Colombani, P., Späti, S., Spleiss, C., Frey-Rindova, P., & Wenk, C. (1997) · Zeitschrift für Ernährungswissenschaft · doi:10.1007/bf01623370 · Cited by 9
The Impact of Nutritional Supplementation on Sweat Metabolomic Content: A Proof-of-Concept Study
Harshman, S. W., Browder, A. B., Davidson, C. N., Pitsch, R. L., Strayer, K. E., Schaeublin, N. M., Phelps, M. S., O’Connor, M. L., Mackowski, N. S., Barrett, K. N., et al. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.659583 · Cited by 7
Glycogen depletion as indication for ammonia determination in exercise testing
Schulz, H., & Heck, H. (2003) · European Journal of Sport Science · doi:10.1080/17461390300073303 · Cited by 6
“To some degree, great increases of ammonia concentration occur through interference with sweet (8, 9), hemolysis (17), and blood clotting (31).”
BackgroundHanitra, I. N., Criscuolo, F., Carrara, S., & Micheli, G. D. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3118945 · Cited by 5
“For instance, in sport applications, wearable sweat sensors are used to monitor muscle activity and fatigue by tracking potassium and ammonium ions concentration [5], [6].”
BackgroundFerreira, R. T., Gonçalves, S. C., Pedrosa, M. L., et al. (2018) · British Journal Of Nutrition · doi:10.1017/s0007114518001770 · Cited by 4
Analysis of Sweat Simulant Mixtures using Multiplexed Arrays of DNA-Carbon Nanotube Vapor Sensors
Kybert, N. J., Egan, L., Waldman, R. Z., X-N, Z., Krein, M. P., Preti, G., Ja, S., & Johnson, A. T. C. (2014) · JOURNAL OF FORENSIC SCIENCE & CRIMINOLOGY · doi:10.15744/2348-9804.1.s102 · Cited by 4
Carbohydrate availability affects ammonemia during exercise after β2-adrenergic blockade
Matthys, D., Derave, W., Calders, P., & Pannier, J. L. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200005000-00010 · Cited by 3
Werner, T. (2006) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Ernährung im Ausdauersport. Anpassung des Makronähr stoffverhältnisses an die Belastungsintensität
Prinzhausen, J., Fikenzer, S., Herget, M., Bänsch, M., & Albers, T. (2010)
Arm crank power and hyperammonemia in respones to L-Aspartic Acid supplementation
Edwards, W. W. (2002) · Louisiana State University · doi:10.31390/gradschool_dissertations.2250
“The terminal nitrogen products of ammonia and urea leave the body via sweat, the lungs, and/or diluted in urine (Czarnowski et al., 1995).”
BackgroundResultSmartphone-Based Ammonium Ion Biosensor for Sweat Analysis
Ni, Y., & Liu, H. (2019) · Science Discovery · doi:10.11648/j.sd.20190702.11
“等考察了血液中铵和尿素水平与汗液中铵浓度之间的关 系,他们的研究表明,血浆中的氨是汗液中铵的主要来源 [5]。此外,在短期运动期间,铵主要通过出汗分泌[6, 7]。 通过对运动员进行的长时间研究,在运动前后,血液中的 铵浓度有着显著增长,运动时血液中的铵浓度几乎是平常 的三倍[8]。此外,长时间的低碳水化合物饮食,也会影响 汗液中的铵水平。在同等运动强度下,低碳水化合物饮食 者比正常饮食者铵浓度更高[9]。总而言之,汗液中铵可用 作蛋白质代谢分解的指标,提供人体在许多不同情况下的 生理信息,例如从有氧运动到无氧运动的变化,以及个人 饮食状况的信息等等。 从分析的角度看,检测汗液中铵离子的主要障碍之一 在于采样。由于汗液样品会在表皮…”
Attia, T. M. (2013) · Journal of Applied Sports Science · doi:10.21608/jass.2013.84837
Dietary Protein and Amino Acids
(2007) · Nutrition in exercise and sport · doi:10.1201/9781420043815.ch4
From Single-Ion to Integrated Multi-Ion Platforms: Wearable Sweat Sensors for Electrolyte Monitoring
Yang, J., Li, J., Han, X., Wei, Z., Wang, G., & Zou, T. (2026) · Biosensors · doi:10.3390/bios16060317 · Cited by 1
“Hepatic dysfunction precludes the efficient conversion of ammonia into urea, rendering elevated sweat ammonium levels a critical prognostic indicator for liver-related pathologies [23].”
Metadata
- Authors
- Czarnowski, D., Langfort, J., Pilis, W., & G�rski, J.
- Affiliations
- Medical University of Białystok (PL)
- Polish Academy of Sciences (PL)
- Venue
- European Journal of Applied Physiology and Occupational Physiology
- Published
- 1995
- Volume
- 70
- Issue
- 1
- Pages
- 70-74
- ISSN
- 0020-9376 (ISSN-L)
- 0301-5548
- 1439-6327
- OpenAlex
- W1999517901
- Semantic Scholar
- 00cad86a8d530966f86656d13263be5b48e5e379
- Cited by
- 28
- References
- 31
- Citations by year
- 2026: 1 · 2023: 2 · 2021: 2 · 2020: 2 · 2019: 1 · 2018: 2 · 2015: 2 · 2014: 1 · 2013: 2
- FWCI
- 0.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology (medical) › Diet and metabolism studies
- Keywords
- low-carbohydrate diet, blood ammonia, ammonia excretion, prolonged exercise, carbohydrate restriction, ammonia synthesis
- MeSH terms
- Adult, Ammonia, Diet, Dietary Carbohydrates, Exercise Test, Glycogen, Humans, Male, Oxygen Consumption, Sweat, Exercise
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.