A potentiometric tattoo sensor for monitoring ammonium in sweat

Guinovart, Tomàs, Bandodkar, Amay J., Windmiller, Joshua R., Andrade, Francisco J., Wang, Joseph·2013·The Analyst

Abstract

The development and analytical characterization of a novel ion-selective potentiometric cell in a temporary-transfer tattoo platform for monitoring ammonium levels in sweat is presented. The fabrication of this skin-worn sensor, which is based on a screen-printed design, incorporates all-solid-state potentiometric sensor technology for both the working and reference electrodes, in connection to ammonium-selective polymeric membrane based on the nonactin ionophore. The resulting tattooed potentiometric sensor exhibits a working range between 10(-4) M to 0.1 M, well within the physiological levels of ammonium in sweat. Testing under stringent mechanical stress expected on the epidermis shows that the analytical performance is not affected by factors such as stretching or bending. Since the levels of ammonium are related to the breakdown of proteins, the new wearable potentiometric tattoo sensor offers considerable promise for monitoring sport performance or detecting metabolic disorders in healthcare. Such combination of the epidermal integration, screen-printed technology and potentiometric sensing represents an attractive path towards non-invasive monitoring of a variety of electrolytes in human perspiration.

Integrity signals

Registry

Crossref · 10.1039/c3an01672b

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Tattoo-based epidermal biosensors have been shown to allow real-time, non-invasive measurements of key sweat electrolytes, heavy metal, and metabolites.

    “Tattoo-based epidermal biosensors have thus been shown to allow real-time, non-invasive measurements of key sweat electrolytes (pH, ammonium or sodium), heavy metal (Zn) and metabolites (lactate or ethanol) (J.K., J.W. et al.)58,70-74.”

    From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [72]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J.
Affiliations
  • University of California San Diego (US)
  • Universitat Rovira i Virgili (ES)
Corresponding author
  • Andrade, Francisco J.
  • Wang, Joseph
Venue
The Analyst
Published
2013
Volume
138
Issue
22
Pages
7031
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2036886659
Cited by
343
References
24
Citations by year
2026: 13 · 2025: 28 · 2024: 31 · 2023: 41 · 2022: 29 · 2021: 36 · 2020: 47 · 2019: 31 · 2018: 25 · 2017: 27 · 2016: 16 · 2015: 10 · 2014: 8 · 2013: 1
FWCI
9.06
Type
journal article
Language
en
Open access
closed
Locations
  • The Analyst (publishedVersion)
  • PubMed (publishedVersion)
  • Repositori institucional URV (Universitat Rovira i Virgili) (submittedVersion)
Topics
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
potentiometric sensors, ammonium, sweat analysis, screen-printed electrodes, all-solid-state electrodes, wearable biosensors, protein degradation, metabolic disorders
MeSH terms
Electrochemistry, Humans, Potentiometry, Sweat, Biosensing Techniques, Ammonium Compounds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review