Plasma ammonia is the principal source of ammonia in sweat
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Sweat contains ammonia. However, neither its source nor factors affecting its concentration in the sweat are known. The aim of this study was to examine the effect of plasma concentrations of ammonia and urea on the concentration of ammonia in the sweat. Four groups of male volunteers were examined: one control, two after ingestion of ammonium chloride, three cirrhotic, hyperammonaemic, four uraemic. Sweat was collected from each subject from the palmar side of the forearm using gauze pads, after previous iontophoresis of pilocarpine. Ammonia and urea concentrations were determined in the sweat and in the plasma. It was found that elevated plasma ammonia concentration in healthy subjects after ingestion of ammonium chloride as well in the cirrhotic patients resulted in an increase of ammonia concentration in the sweat. High plasma and sweat urea concentration in the uraemic subjects did not affect the concentration of ammonia in the sweat. It was concluded that plasma ammonia was the principal source of ammonia in the sweat.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the pH gradient between blood, sweat, and water compartments allows ammonia to passively diffuse across membranes.”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Czarnowski et al. 1992
In the citing paper
“Czarnowski et al. (1992) have proposed instead that plasma ammonia is the main source of ammonia in sweat”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Czarnowski et al. 1992
In the citing paper
“uremic patients had increased sweat urea concentrations, but their sweat ammonia concentrations were similar to controls”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Czarnowski et al. 1992
In the citing paper
“Increased plasma ammonia (in cirrhotic patients and from ammonium ingestion) resulted in increased sweat ammonia concentrations, but no increase in sweat urea concentrations”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Czarnowski et al. 1992
In the citing paper
“while plasma ammonia plays an important role in determining sweat ammonia concentrations (Czarnowski et al. 1992; Sato 1977)”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Czarnowski et al. 1992
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Biochemistry and physiology of brain ammonia.
Cooper, A. J., & Plum, F. (1987) · Physiological Reviews · doi:10.1152/physrev.1987.67.2.440 · Cited by 845
Robinson, S., & Robinson, A. H. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.2.202 · Cited by 514
Effect of initial muscle glycogen levels on protein catabolism during exercise
Lemon, P. W., & Mullin, J. P. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.48.4.624 · Cited by 291
Ammonia metabolism in exercise and fatigue: a review.
Mutch, B. J. C., & Banister, E. W. (1983) · PubMed · Cited by 194
Some Aspects of Ammonia Toxicity in Animal Cells
Visek, W. J. (1968) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(68)86976-0 · Cited by 130 · cited 1×
“The permeability of cell membranes for ammonia is similar to water whereas the permeability for the ammonium ion is small (Hindfelt 1975; Visek 1968 ).”
BackgroundClinical chemistry : theory and practice
Richterich, R. (1969) · Medical Entomology and Zoology · Cited by 110
Quinton, P. M. (1983) · Annual Review of Medicine · doi:10.1146/annurev.me.34.020183.002241 · Cited by 103 · cited 1×
“Sweat has been shown to contain considerable amounts of urea (Robinson and Robinson 1954; Quinton 1983 ).”
BackgroundUREA EXCRETION IN HUMAN SWEAT AS A TRACER FOR MOVEMENT OF WATER WITHIN THE SECRETING GLAND
Schwartz, I. L., Thaysen, J. H., & Dole, V. P. (1953) · Journal of Experimental Medicine · doi:10.1084/jem.97.3.429 · Cited by 85
Stabenau, J. R., Warren, K. S., & Rall, D. P. (1959) · Journal of Clinical Investigation · doi:10.1172/jci103811 · Cited by 84 · cited 2×
“Therefore, the pH gradient between water compartments directs the movement of ammonia across the membranes and thus its distribution ( Stabenau et al. 1959 ).”
BackgroundProtein metabolism during intensive physical training in the young adult
Consolazio, C., Johnson, H., Nelson, R., Dramise, J., & Skala, J. (1975) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/28.1.29 · Cited by 61
Research works printed but not linked: 1
- Da Fonseca-Wollheim F (1973) Direkte Plasmaammoniakbestimmung ohne Enteiweibung. Z Klin Chem Klin Biochem 11: 426–431
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Ammonia in breath and emitted from skin
Schmidt, F. M., Vaittinen, O., Metsälä, M., Lehto, M. J., Forsblom, C. M., Groop, P., & Halonen, L. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/1/017109 · Cited by 134
“Previous research has excluded (iii) but is still divided whether most of the sweat ammonia originates from plasma [53, 65, 66] or the sweat glands [54].”
BackgroundCentral and Peripheral Fatigue During Resistance Exercise – A Critical Review
Zając, A., Chalimoniuk, M., Gołaś, A., Lngfort, J., & Maszczyk, A. (2015) · Journal of Human Kinetics · doi:10.1515/hukin-2015-0118 · Cited by 161
“…issues and ammonia metabolism in relation to brain and fatigue have been excellently reviewed and discussed by Wilkinson et al. (2010) despite the fact that the authors did not pay any attention to sweat ammonia excretion during exercise (Czarnowski and Górski 1991, Czarnowski et al. 1992).”
Determination of Ammonia in Biological Fluids
Huizenga, J. R., Tangerman, A., & Gips, C. (1994) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329403100602 · Cited by 103
Access and Management of Sweat for Non‐Invasive Biomarker Monitoring: A Comprehensive Review
Saha, T., Caño, R. D., la Paz, E. D., Sandhu, S. S., & Wang, J. (2022) · Small · doi:10.1002/smll.202206064 · Cited by 105
Dormont, L., Mulatier, M., Carrasco, D., & Cohuet, A. (2021) · Journal of Chemical Ecology · doi:10.1007/s10886-021-01261-2 · Cited by 108
Microbiota and Malodor—Etiology and Management
Mogilnicka, I., Bogucki, P., & Ufnal, M. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21082886 · Cited by 110
“Some researchers concluded that it is transported from plasma [145] while others claim that it comes directly from sweat glands [75].”
BackgroundKlous, L., de Ruiter, C. J., Scherrer, S., Gerrett, N., & Daanen, H. A. M. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04562-8 · Cited by 86
“2005) and origination from blood plasma (Czarnowski et al. 1992).”
BackgroundResultInfluentialCuartero, M., Colozza, N., Fernández-Pérez, B. M., & Crespo, G. A. (2020) · The Analyst · doi:10.1039/d0an00327a · Cited by 90
Assalve, G., Lunetti, P., di Cagno, A., Luca, E. W. D., Aldegheri, S., Zara, V., & Ferramosca, A. (2024) · Biosensors · doi:10.3390/bios14120574 · Cited by 100
Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases
Tricoli, A., & Neri, G. (2018) · Sensors · doi:10.3390/s18040942 · Cited by 78
“Plasma ammonia is the principal source of ammonia in sweat [72].”
BackgroundSweat Lactate, Ammonia, and Urea in Rugby Players
Alvear-Ordenes, I., García-López, D., De Paz, J. A., & González-Gallego, J. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830380 · Cited by 67
Passornraprasit, N., Siripongpreda, T., Ninlapruk, S., Rodthongkum, N., & Potiyaraj, P. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.06.053 · Cited by 64
Optimization of printed sensors to monitor sodium, ammonium, and lactate in sweat
Zamarayeva, A. M., Yamamoto, N. A. D., Toor, A., Payne, M. E., Woods, C., Pister, V. I., Khan, Y., Evans, J. W., & Arias, A. C. (2020) · APL Materials · doi:10.1063/5.0014836 · Cited by 68
Microfluidic wearable electrochemical sweat sensors for health monitoring
Balaji, R., & Liao, Y. (2022) · Biomicrofluidics · doi:10.1063/5.0116648 · Cited by 65
The origin of mouth-exhaled ammonia
Chen, W., Metsälä, M., Vaittinen, O., & Halonen, L. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/036003 · Cited by 58
Identification of Ammonia in Gas Emanated from Human Skin and Its Correlation with That in Blood
Nose, K., Mizuno, T., Yamane, N., Kondo, T., Ohtani, H., Araki, S., & Tsuda, T. (2005) · Analytical Sciences · doi:10.2116/analsci.21.1471 · Cited by 53
Smith, D. C., & Španěl, P. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/2/022001 · Cited by 37
Optical sensors for transdermal biomarker detection: A review
Amjad, A., & Xian, X. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116844 · Cited by 41
Printed Organic Transistor-based Biosensors for Non-invasive Sweat Analysis
Nagamine, K., Nomura, A., Ichimura, Y., Izawa, R., Sasaki, S., Furusawa, H., Matsui, H., & Tokito, S. (2020) · Analytical Sciences · doi:10.2116/analsci.19r007 · Cited by 40
Yuan, Y., So, R., Wong, S. H., & Chan, K. M. K. (2002) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1034/j.1600-0838.2002.00185.x · Cited by 34
Czarnowski, D., Langfort, J., Pilis, W., & G�rski, J. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00601811 · Cited by 28
Self-citationPetrelli, M., Shkodra, B., Falco, A., Angeli, M. A. C., Vásquez, S., Scarton, A. M., Pogliaghi, S., Biasi, R., Lugli, P., & Petti, L. (2023) · Organic Electronics · doi:10.1016/j.orgel.2023.106889 · Cited by 30
Human Sweat Analysis Using a Portable Device Based on a Screen‐printed Electrolyte Sensor
Hauke, A., Oertel, S., Jank, M. P. M., Frey, L., Langenstein, B., & Bertsch, T. (2017) · Electroanalysis · doi:10.1002/elan.201700672 · Cited by 24
Archaea Are Rare and Uncommon Members of the Mammalian Skin Microbiome
Umbach, A. K., Stegelmeier, A. A., & Neufeld, J. D. (2021) · mSystems · doi:10.1128/msystems.00642-21 · Cited by 26
“Mammalian skin might also passively diffuse ammonia (65, 66) or excrete it in sweat (67), and there is the potential for localized skin diseases to increase ammonia production (68).”
BackgroundValidating sweat ammonia as physiological parameter for wearable devices in sports science
Renner, E., Lang, N. R., Langenstein, B., Struck, M., & Bertsch, T. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175434 · Cited by 23
“Lactate concentration is determined using blood samples and cannot be measured non-invasively in sweat [6,9].”
BackgroundDermal-fluid-enabled detection platforms for non-invasive ambulatory monitoring
Veronica, A., Li, Y., Li, Y., Hsing, I., & Nyein, H. Y. Y. (2023) · Sensors & Diagnostics · doi:10.1039/d3sd00165b · Cited by 19
TERASAWA, J., Mitsuya, K., Ishii, A., & Tsuda, T. (2001) · BUNSEKI KAGAKU · doi:10.2116/bunsekikagaku.50.813 · Cited by 16
菅瀬貞治, & Tsuda, T. (2002) · BUNSEKI KAGAKU · doi:10.2116/bunsekikagaku.51.429 · Cited by 15
Infante, V. H. P., Bennewitz, R., Kröger, M., Meinke, M. C., & Darvin, M. E. (2023) · Experimental Dermatology · doi:10.1111/exd.14802 · Cited by 10
Monitoring of biomarkers in sweat with printed sensors combined with sport wearables
Oertel, S., Jank, M. P. M., Schmitz, B., & Lang, N. R. (2016) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/2968219.2968574 · Cited by 11
“Czarnowski et al. (1992) published the mechanism of the ammonia transport from muscle cells into sweat [5].”
BackgroundInfluentialPatil, N. J., Vishnuraj, R., Mani, G. K., Rangarajan, M., & Srinivasan, P. (2025) · Electrochimica Acta · doi:10.1016/j.electacta.2025.146716 · Cited by 7
The valley of death in translation: Challenges and pathways for wearable microfluidic sweat sensors
Yan, H., Fu, S., & Guo, Z. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.170306 · Cited by 6
Smart, Portable, and Noninvasive Diagnostic Biosensors for Healthcare
Kanaparthi, S., Supraja, P., & Singh, S. G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815743-5.00007-x · Cited by 6
Human Subjects Testing of Sweat Stimulation Technologies
Wilder, E. (2016) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 4
Generation mechanisms of hydrogen cyanide and ammonia in human exhaled breath
Chen, W. (2016) · Helda - University of Helsinki Institutional Repository · Cited by 2
From Single-Ion to Integrated Multi-Ion Platforms: Wearable Sweat Sensors for Electrolyte Monitoring
Yang, J., Li, J., Han, X., Wei, Z., Wang, G., & Zou, T. (2026) · Biosensors · doi:10.3390/bios16060317 · Cited by 1
“Conversely, elevated K + concentrations can induce hyperkalemia, leading to severe cardiac arrhythmia or even sudden cardiac arrest [22].”
Smartphone-Based Ammonium Ion Biosensor for Sweat Analysis
Ni, Y., & Liu, H. (2019) · Science Discovery · doi:10.11648/j.sd.20190702.11
“等考察了血液中铵和尿素水平与汗液中铵浓度之间的关 系,他们的研究表明,血浆中的氨是汗液中铵的主要来源 [5]。此外,在短期运动期间,铵主要通过出汗分泌[6, 7]。 通过对运动员进行的长时间研究,在运动前后,血液中的 铵浓度有着显著增长,运动时血液中的铵浓度几乎是平常 的三倍[8]。此外,长时间的低碳水化合物饮食,也会影响 汗液中的铵水平。在同等运动强度下,低碳水化合物饮食 者比正常饮食者铵浓度更高[9]。总而言之,汗液中铵可用 作蛋白质代谢分解的指标,提供人体在许多不同情况下的 生理信息,例如从有氧运动到无氧运动的变化,以及个人 饮食状况的信息等等。 从分析的角度看,检测汗液中铵离子的主要障碍之一 在于采样。由于汗液样品会在表皮…”
Profiling skin-associated archaea and bacteria with 16S rRNA and cpn60 genes
Umbach, A. K. (2021) · UWSpace (University of Waterloo)
Cáparra, parada y fonda en la Vía de la Plata
Uceta, A. D. (2003) · La Aventura de la historia
Characterization of age-associated gene expression changes in mouse sweat glands
Zonnefeld, A. G., Cui, C., Tsitsipatis, D., Piao, Y., Fan, J., Mazan-Mamczarz, K., Xue, Y., Indig, F. E., De, S., & Gorospe, M. (2024) · Aging · doi:10.18632/aging.205776 · Cited by 9
“As sweat contains ammonia, which provides odor [32], elevated RHCG may increase odor in old mice.”
BackgroundWearable Sweat Sensors: A Review
Chowdhury, I., Ali, M. Y., & Howlader, M. M. R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95478-5.00015-7 · Cited by 2
A Review of 3D Printed CMOS Electrochemical Biosensors for Smart Liver Disease Diagnosis
Saju, S., Abishek, R., Dhurushanthini, K., Luxshiba, K., & Nithin, V. (2025) · International Conference on Electronics, Communication and Aerospace Technology (ICECA) · doi:10.1109/iceca66444.2025.11383048
Emerging wearable sweat sensors for monitoring sports health
Wen, H., Huang, F., Gao, Z., Cao, Y., Liu, F., Li, A., Cai, W., Pan, T., & Liu, Q. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118977
Metadata
- Authors
- Czarnowski, D., Górski, J., Jóźwiuk, J., & Boroń-Kaczmarska, A.
- Affiliations
- Medical University of Białystok (PL)
- ORCID
- Górski, Jan
- Venue
- European Journal of Applied Physiology and Occupational Physiology
- Published
- 1992-03
- Volume
- 65
- Issue
- 2
- Pages
- 135-137
- ISSN
- 0020-9376 (ISSN-L)
- 0301-5548
- 1439-6327
- OpenAlex
- W2078283643
- Cited by
- 48
- References
- 19
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 4 · 2023: 4 · 2022: 3 · 2021: 3 · 2020: 7 · 2019: 2 · 2018: 2 · 2017: 1 · 2016: 3 · 2015: 3 · 2014: 1 · 2013: 2
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biochemistry › Amino Acid Enzymes and Metabolism
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- blood ammonia, urea, liver cirrhosis, hyperammonemia, uremia, sweat composition, ammonia excretion
- MeSH terms
- Administration, Oral, Adult, Ammonia, Humans, Liver Cirrhosis, Male, Pilocarpine, Sweat, Urea
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).