Blood pressure monitoring: Automated oscillometric devices

Ramsey, Maynard·1991·Journal of Clinical Monitoring

Abstract

An understanding of the principles of blood pressure measurement with automated oscillometric devices (e.g., Dinamap) allows a user to realize the purpose and level of accuracy for which the equipment is designed. Good technique cells for various actions: (1) using a cuff of proper size (too large a cuff will generally work acceptably, but too small a cuff will yield erroneously high readings); (2) squeezing all of the residual air out of the cuff before applying it to the arm or leg; (3) wrapping the cuff snugly around the arm or leg; (4) instructing the patient to refrain from talking or moving and letting nothing press against the cuff during measurement; (5) keeping the cuff and heart at the same horizontal level. (6) When instrument malfunction is suspected, first checking the status of the patient (not the status of the instrument) to be sure that a clinical emergency is not causing the suspected "malfunction"; (7) repeating a reading several times when it is suspicious and, if necessary, modifying the measurement conditions by using, for example, different limbs or different cuffs until the question is resolved; and (8) remembering that a leak in the cuff, hoses, or connection can cause an unexpected malfunction.

Integrity signals

Registry

Crossref · 10.1007/bf01617900

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Automated BPMDs use proprietary algorithms to estimate BP by analysis of cuff pressure waveform signals, and this approach has remained mostly unchanged for decades.

    “For automated BPMDs, these processes are undertaken electronically and based on proprietary algorithms designed to estimate BP by analysis of cuff pressure waveform signals detected because they are transmitted from the cuff into the tubing system (and onwards to the pressure transducer), and ultimately processed by microcomputer. This approach has remained mostly unchanged for decades [13, 44, 45”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ramsey, M.
Corresponding author
Ramsey, Maynard
Venue
Journal of Clinical Monitoring
Published
1991-01
Volume
7
Issue
1
Pages
56-67
ISSN
0748-1977 (ISSN-L)
OpenAlex
W2049364112
Cited by
155
References
1
Citations by year
2026: 1 · 2024: 4 · 2023: 3 · 2022: 3 · 2021: 5 · 2020: 8 · 2019: 2 · 2018: 5 · 2017: 1 · 2016: 7 · 2015: 3 · 2014: 2 · 2013: 3 · 2012: 3
FWCI
5.91
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Clinical Monitoring (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
blood pressure measurement, cuff size, measurement methods, cuff leak, instrument malfunction, measurement accuracy, patient positioning
MeSH terms
Equipment Failure, Humans, Microcomputers, Oscillometry, Blood Pressure Monitors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review