CoChat

Clinical magnetocardiography: Experience with a biomagnetic multichannel system

Moshage, Werner, Achenbach, Stephan, Weikl, Andreas, Göhl, Konrad, Bachmann, Kurt, Abraham-Fuchs, Klaus, Härer, Wolfgang, Schneider, Siegfried · 1991 · The International Journal of Cardiac Imaging

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The magnetic fields caused by the human heart's electrical activity were coherently recorded with a biomagnetic multichannel system (KRENIKON) during 1 to 10 minutes in 49 patients. 31 to 37 magnetic channels were recorded simultaneously with the ECG and respiration. Comparison of a magnetic index and the Sokolow-Lyon index to echocardiographic findings in the quantification of left ventricular hypertrophy demonstrated the superiority of the magnetocardiogram (MCG) as compared to the ECG. The magnetocardiographic investigation of patients with WPW-Syndrome, ventricular extrasystoles, ventricular tachycardia, and paced ventricular beats demonstrated that multichannel magnetocardiography permits the non-invasive three dimensional localization of arrhythmogenic tissue with high spatial accuracy.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf01797754

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 13 references

Research works printed but not linked: 3

  1. Erné SN. High resolution magnetocardiography: Modeling and sources localization. Med Biol Eng Comput 1985; 23: 1447.
  2. Moshage W, Abraham-Fuchs K, Weikl A, Schneider S, Bachmann K, Schittenhelm R. Magnetocardiography (MCG): non-invasive localization of accessory conduction pathways in patients with the WPW syndrome. Electromedica 1989; 57: 122–8.
  3. Moshage W, Weikl A, Abraham-Fuchs K, Schneider S, Göhl K, Feistel H, et al. Magnetokardiographie: Erste klinische Erfahrungen mit einem biomagnetischen Vielkanalsystem. Herz/Kreisl. 1990; 22: 245–9.

Cited by

Metadata

Authors
Moshage, W., Achenbach, S., Weikl, A., Göhl, K., Bachmann, K., Abraham-Fuchs, K., Härer, W., & Schneider, S.
Affiliations
  • Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
  • Siemens (Germany) (DE)
Venue
The International Journal of Cardiac Imaging
Published
1991-09
Volume
7
Issue
3-4
Pages
217-223
ISSN
  • 0167-9899 (ISSN-L)
  • 1573-0743
OpenAlex
W2038087127
Cited by
17
References
13
Citations by year
2025: 2 · 2024: 1 · 2023: 2 · 2012: 1
FWCI
0.35
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • International journal of cardiac imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
Keywords
magnetocardiography, left ventricular hypertrophy, Sokolow-Lyon index, ECG comparison, arrhythmia localization, Wolff-Parkinson-White syndrome, premature ventricular contractions, ventricular tachycardia, noninvasive cardiac imaging
MeSH terms
Action Potentials, Adult, Electrocardiography, Cardiac Complexes, Premature, False Negative Reactions, Female, Heart Conduction System, Cardiomegaly, Heart Ventricles, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Models, Cardiovascular, Tachycardia, Wolff-Parkinson-White Syndrome, Electromagnetic Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.