Clinical magnetocardiography: Experience with a biomagnetic multichannel system
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The magnetic fields caused by the human heart's electrical activity were coherently recorded with a biomagnetic multichannel system (KRENIKON) during 1 to 10 minutes in 49 patients. 31 to 37 magnetic channels were recorded simultaneously with the ECG and respiration. Comparison of a magnetic index and the Sokolow-Lyon index to echocardiographic findings in the quantification of left ventricular hypertrophy demonstrated the superiority of the magnetocardiogram (MCG) as compared to the ECG. The magnetocardiographic investigation of patients with WPW-Syndrome, ventricular extrasystoles, ventricular tachycardia, and paced ventricular beats demonstrated that multichannel magnetocardiography permits the non-invasive three dimensional localization of arrhythmogenic tissue with high spatial accuracy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“That multichannel MCG system provided accurate localization of the arrhythmogenic substrates of patients with the Wolff–Parkinson–White syndrome and with ventricular tachycardia validated with successful catheter ablation (152).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [152]
Citations
Cites
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392 · cited 1×
“The magnetocardiogram was recorded for the first time in 1963 by Baule and McFee [2].”
MethodBiomagnetism: An Interdisciplinary Approach
Kaufman, L., & Williamson, S. J. (1983) · Medical Entomology and Zoology · Cited by 168
Multichannel biomagnetic system for study of electrical activity in the brain and heart
Schneider, S., Hoenig, E., Reichenberger, H., Abraham-Fuchs, K., Moshage, W., Oppelt, A., Stefan, H., Weikl, A., & Wirth, A. (1990) · Radiology · doi:10.1148/radiology.176.3.2389043 · Cited by 74 · cited 2×
“The system is based on 37 first-order gradiometers arranged in a planar array with a diameter of 19 cm [11].”
BackgroundMethodSelf-citationFujino, K., Sumi, M., Saito, K., Murakami, M., Higuchi, T., Nakaya, Y., & Mori, H. (1984) · Journal of Electrocardiology · doi:10.1016/s0022-0736(84)80058-8 · Cited by 35 · cited 1×
“[6] have reported a higher sensitivity of the MCG as compared to the ECG in the detection of left ventricular hypertrophy.”
MethodProgress in Biomagnetic Imaging of Heart Arrhythmias
Moshage, W. E. L., Achenbach, S. S., Weikl, A., Göhl, K., Abraham‐Fuchs, K., Schneider, S., & Bachmann, K. (1991) · Frontiers in European radiology · doi:10.1007/978-3-642-76099-0_1 · Cited by 31
Self-citationBiomagnetic localization of ventricular arrhythmias.
Moshage, W. E. L., Achenbach, S., Göhl, K., Weikl, A., Bachmann, K., Wegener, H. P., Schneider, S., & Härer, W. (1991) · Radiology · doi:10.1148/radiology.180.3.1714612 · Cited by 28
Self-citationFenici, R., Melillo, G., Cappelli, A., Luca, C. D., & Masselli, M. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_94 · Cited by 11 · cited 1×
“There have been previous reports on the localization of the accessory bundles in WPW-Syndrome and of arrhythmogenic tissues [4, 5, 7].”
BackgroundAchonbach, S., Moshago, W., Welkl, A., Härer, W., Abraham‐Fuchs, K., Göhl, K., & Bachmann, K. F. (1990) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1990.35.s3.160 · Cited by 10 · cited 1×
“Digital subtraction of the superimposed activity was performed to render possible the localization in these cases [1]: Normal beats were averaged to obtain a template of repolarization activity.”
MethodSelf-citationLocalization of the accessory cardiac conduction pathway
Katila, T. E. (1988) · Medical Entomology and Zoology · Cited by 9
A Non-Magnetic, MR-Compatible Pacing Catheter for Clinical Application in Magnetocardiography
Moshage, W. E. L., Achenbach, S. S., Bolz, A., Welkl, A., Wegener, H. P., Bachmann, K. F., & Schaldach, M. (1990) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1990.35.s3.162 · Cited by 6
Self-citationFenici, R., Masselli, M., Lopez, L. D., & Melillo, G. (1988) · Cited by 5
Magnetocardiographic three-dimensional localization of Kent bundles
Fenici, R., Melillo, G., Masselli, M., & Cappelli, A. (1989) · Cited by 2
Research works printed but not linked: 3
- Erné SN. High resolution magnetocardiography: Modeling and sources localization. Med Biol Eng Comput 1985; 23: 1447.
- Moshage W, Abraham-Fuchs K, Weikl A, Schneider S, Bachmann K, Schittenhelm R. Magnetocardiography (MCG): non-invasive localization of accessory conduction pathways in patients with the WPW syndrome. Electromedica 1989; 57: 122–8.
- Moshage W, Weikl A, Abraham-Fuchs K, Schneider S, Göhl K, Feistel H, et al. Magnetokardiographie: Erste klinische Erfahrungen mit einem biomagnetischen Vielkanalsystem. Herz/Kreisl. 1990; 22: 245–9.
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Solving the inverse problem in magnetocardiography
Nenonen, J. T. (1994) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.310989 · Cited by 59
Brala, D., Thevathasan, T., Grahl, S., Barrow, S., Violano, M., Bergs, H., Golpour, A., Suwalski, P., Poller, W., Skurk, C., et al. (2023) · Journal of the American Heart Association · doi:10.1161/jaha.122.027619 · Cited by 54
“21,22 Data can be obtained at rest within 60 seconds of measurement time.”
Moshage, W. E. L., Achenbach, S. S., Göhl, K., & Bachmann, K. F. (1996) · International journal of cardiac imaging · doi:10.1007/bf01798116 · Cited by 51
Self-citationdel Campo, A. A., Sparks, A., Hill, R. C., & Keller, R. T. (1999) · IEEE Transactions on Engineering Management · doi:10.1109/17.775281 · Cited by 43
Metadata
- Authors
- Moshage, W., Achenbach, S., Weikl, A., Göhl, K., Bachmann, K., Abraham-Fuchs, K., Härer, W., & Schneider, S.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Siemens (Germany) (DE)
- ORCID
- Achenbach, Stephan
- Venue
- The International Journal of Cardiac Imaging
- Published
- 1991-09
- Volume
- 7
- Issue
- 3-4
- Pages
- 217-223
- ISSN
- 0167-9899 (ISSN-L)
- 1573-0743
- OpenAlex
- W2038087127
- Cited by
- 17
- References
- 13
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 2 · 2012: 1
- FWCI
- 0.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- International journal of cardiac imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- magnetocardiography, left ventricular hypertrophy, Sokolow-Lyon index, ECG comparison, arrhythmia localization, Wolff-Parkinson-White syndrome, premature ventricular contractions, ventricular tachycardia, noninvasive cardiac imaging
- MeSH terms
- Action Potentials, Adult, Electrocardiography, Cardiac Complexes, Premature, False Negative Reactions, Female, Heart Conduction System, Cardiomegaly, Heart Ventricles, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Models, Cardiovascular, Tachycardia, Wolff-Parkinson-White Syndrome, Electromagnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.