Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Toward robot-assisted vascular microsurgery in the retina

Jensen, Patrick S., Grace, Kenneth W., Attariwala, Rajpaul, Colgate, J. Edward, Glucksberg, Matthew R. · 1997 · Graefe's Archive for Clinical and Experimental Ophthalmology

Abstract

Background Experimental protocol in our laboratory routinely requires the precise placement of instruments at, or near, the retina. Although manipulators for placing an instrument within the eye presently exist, none of the designs were satisfactory due to limitations on size, accuracy and operability. To overcome these limitations, we have developed a novel six degree of freedom manipulator designed specifically for retinal microsurgery. Methods The manipulator is parallel in structure and provides submicrometer positioning of an instrument within the constrained environment of the eye. The position of an instrument attached to the manipulator is commanded by the operator using a hand-held trackball. A computer controller interprets the trackball input and moves the manipulator in an intuitive manner according to mathematically constrained modes of operation. Results Over 50 retinal vessels in the live, anesthetized cat have been successfully cannulated for pressure measurement and drug injection using the described manipulator and micropuncture techniques. The targeted vessels ranged in internal diameter from 20 to 130 microns. Conclusion This device has applications in microsurgery where tremor and fatigue limit the performance of an unaided hand and where mechanically constrained manipulators are inappropriate due to size and operative constraints.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf01880668

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 13 references

Research works printed but not linked: 2

  1. Charles S (1994) Dexterity enhancement for surgery. Proc First Int'l Symp Med Robotics Comput Assist Surg 2:145–160
  2. Grace KW (1995) Kinematic design of an ophthalmic surgery robot and feature extracting bilateral manipulation. Ph D thesis, Northwestern University, Evanston, Ill

Cited by

See all 90

Metadata

Authors
Jensen, P. S., Grace, K. W., Attariwala, R., Colgate, J. E., & Glucksberg, M. R.
Affiliations
Northwestern University (US)
Corresponding author
Glucksberg, Matthew R.
Venue
Graefe's Archive for Clinical and Experimental Ophthalmology
Published
1997-11
Volume
235
Issue
11
Pages
696-701
ISSN
  • 0721-832X (ISSN-L)
  • 1435-702X
OpenAlex
W2066140684
Cited by
90
References
13
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 4 · 2020: 4 · 2019: 4 · 2018: 1 · 2017: 6 · 2016: 5 · 2015: 6 · 2014: 5 · 2013: 5 · 2012: 9
FWCI
1.20
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Graefe s Archive for Clinical and Experimental Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01ey009714-07)
  • National Eye Institute (EY-09714)
Topics
  • Health Sciences › Medicine › Ophthalmology › Retinal and Macular Surgery
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
Keywords
robotic surgery, retinal microsurgery, parallel manipulators, 6-DOF manipulator, retinal vasculature, micropuncture, drug injection
MeSH terms
Animals, Cats, Equipment Design, Microsurgery, Retinal Vessels, Robotics, Therapy, Computer-Assisted

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.