A method for detecting myocardial abnormality by using a current-ratio map calculated from an exercise-induced magnetocardiogram
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
A method for making a current-ratio map to determine the ischaemic area of angina pectoris (AP) patients has been developed. This method uses a current-arrow map calculated using a ORS wave from 64-channel magnetocardiogram (MCG) signals. The current-ratio map can be calculated from the ratio of an exercise-induced current vector to an at-rest current vector. The MCG signals of eight patients with angina pectoris (AP) (six patients with effort AP and two patients with variant AP) and four healthy volunteers were measured before and after a two-step exercise test. The current-ratio maps of the six patients with effort AP showed three distinct patterns: a left-circumflex-artery (LCX) pattern; a right-coronary-artery (RCA) pattern; and a left-anterior-descending (LAD) pattern. The maximum current ratios of these three patterns differed from those of normal patterns. The patterns of two patients with variant AP were similar to normal patterns. Furthermore, a comparison of the current-ratio map before and after percutaneous-transluminal-coronary-angioplasty (PTCA) treatment indicated that the cardiac ischaemia was reduced in all patients. An appropriate criterion to diagnose abnormality in a patient with an ischaemic myocardial area seems to be a maximum current ratio exceeding 0.4 to 0.5. Based on these preliminary results, it is believed that the location of an ischaemic area (the coronary artery part) can be estimated by using the ischaemic current-ratio map pattern.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The exercise ECG (eECG), which records the electrical signal of patients in exercise, is a widely used diagnostic procedure in the evaluation of both normal participants and cardiologic patients with coronary heart disease (13–16).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [15]
In the citing paper
“However, despite the great clinical significance of movable MCG systems, few studies have been reported (14, 15, 23–27).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [15]
Citations
Cites
BROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99
Hänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74
Part IV Visual determination of generators of the magnetocardiogram
Hosaka, H., & Cohen, D. (1976) · Journal of Electrocardiology · doi:10.1016/s0022-0736(76)80043-x · Cited by 74
On selecting a body surface mapping procedure
Hoekema, R., Uijen, G. J. H., & van Oosterom, A. (1999) · Journal of Electrocardiology · doi:10.1016/s0022-0736(99)90088-2 · Cited by 74
Tsukada, K., Miyashita, T., Kandori, A., Mitsui, T., Terada, Y., Sato, M., Shiono, J., Horigome, H., Yamada, S., & Yamaguchi, I. (2000) · International journal of cardiac imaging · doi:10.1023/a:1006376326755 · Cited by 70
Self-citationMultichannel SQUID system detecting tangential components of the cardiac magnetic field
Tsukada, K., Haruta, Y., Adachi, A., Ogata, H., Komuro, T., Ito, T., Takada, Y., Kandori, A., Noda, Y., Terada, Y., et al. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146524 · Cited by 69
Self-citationLant, J., Stroink, G., ten Voorde, B., Horacek, B. M., & Montague, T. J. (1990) · Journal of Electrocardiology · doi:10.1016/0022-0736(90)90121-h · Cited by 63
The magnetocardiogram in cardiac disorders
SAARINEN, M., KARP, P. J., KATILA, T. E., & SILTANEN, P. (1974) · Cardiovascular Research · doi:10.1093/cvr/8.6.820 · Cited by 61
Non-invasive imaging of arrhythmogenic left-ventricular myocardium after infarction
Leder, U., Haueisen, J., Huck, M., & Nowak, H. (1998) · The Lancet · doi:10.1016/s0140-6736(98)00082-8 · Cited by 48
Kandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., & Tsukada, K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345262 · Cited by 47
Self-citation
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“However, despite the great clinical significance of movable MCG systems, few studies have been reported ( 14 , 15 , 23 – 27 ).”
Kandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., & Tsukada, K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345262 · Cited by 47
Self-citationKandori, A., Miyashita, T., Tsukada, K., Hosono, T., Miyashita, S., Chiba, Y., Horigome, H., Shigemitsu, S., & Asaka, M. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/2/309 · Cited by 35
Self-citationHaberkorn, W., Steinhoff, U., Burghoff, M., Kosch, O., Morguet, A. J., & Koch, H. C. (2006) · BioMagnetic Research and Technology · doi:10.1186/1477-044x-4-5 · Cited by 31
“1, 2, 3 illustrate this point: it shows two instants of the atrial excitation marked by the cursors in the MCGbutterfly-plot in Fig.”
MethodInfluential
Metadata
- Authors
- Kandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., & Tsukada, K.
- Affiliations
- Hitachi (Japan) (JP)
- National Cerebral and Cardiovascular Center (JP)
- Corresponding author
- Kandori, A.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2001-01
- Volume
- 39
- Issue
- 1
- Pages
- 29-34
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2040416572
- Cited by
- 45
- References
- 24
- Citations by year
- 2024: 1 · 2023: 1 · 2021: 1 · 2017: 3 · 2013: 1 · 2012: 1
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- magnetocardiography, angina pectoris, myocardial ischemia, coronary artery disease, percutaneous transluminal coronary angioplasty, two-step exercise test
- MeSH terms
- Angina Pectoris, Exercise Test, Humans, Magnetics, Myocardium, Signal Processing, Computer-Assisted, Case-Control Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.