CoChat

A method for detecting myocardial abnormality by using a current-ratio map calculated from an exercise-induced magnetocardiogram

Kandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., Tsukada, K. · 2001 · Medical & Biological Engineering & Computing

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

A method for making a current-ratio map to determine the ischaemic area of angina pectoris (AP) patients has been developed. This method uses a current-arrow map calculated using a ORS wave from 64-channel magnetocardiogram (MCG) signals. The current-ratio map can be calculated from the ratio of an exercise-induced current vector to an at-rest current vector. The MCG signals of eight patients with angina pectoris (AP) (six patients with effort AP and two patients with variant AP) and four healthy volunteers were measured before and after a two-step exercise test. The current-ratio maps of the six patients with effort AP showed three distinct patterns: a left-circumflex-artery (LCX) pattern; a right-coronary-artery (RCA) pattern; and a left-anterior-descending (LAD) pattern. The maximum current ratios of these three patterns differed from those of normal patterns. The patterns of two patients with variant AP were similar to normal patterns. Furthermore, a comparison of the current-ratio map before and after percutaneous-transluminal-coronary-angioplasty (PTCA) treatment indicated that the cardiac ischaemia was reduced in all patients. An appropriate criterion to diagnose abnormality in a patient with an ischaemic myocardial area seems to be a maximum current ratio exceeding 0.4 to 0.5. Based on these preliminary results, it is believed that the location of an ischaemic area (the coronary artery part) can be estimated by using the ischaemic current-ratio map pattern.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf02345263

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Cited by

Metadata

Authors
Kandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., & Tsukada, K.
Affiliations
  • Hitachi (Japan) (JP)
  • National Cerebral and Cardiovascular Center (JP)
Corresponding author
Kandori, A.
Venue
Medical & Biological Engineering & Computing
Published
2001-01
Volume
39
Issue
1
Pages
29-34
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W2040416572
Cited by
45
References
24
Citations by year
2024: 1 · 2023: 1 · 2021: 1 · 2017: 3 · 2013: 1 · 2012: 1
FWCI
4.87
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
Keywords
magnetocardiography, angina pectoris, myocardial ischemia, coronary artery disease, percutaneous transluminal coronary angioplasty, two-step exercise test
MeSH terms
Angina Pectoris, Exercise Test, Humans, Magnetics, Myocardium, Signal Processing, Computer-Assisted, Case-Control Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.