CoChat

Attenuation of pathological tremors by functional electrical stimulation I: Method

Prochazka, Arthur, Elek, Josef, Javidan, Manouchehr · 1992 · Annals of Biomedical Engineering

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

In this study we explored the possibility of suppressing pathological tremors using closed-loop functional electrical stimulation (FES) to activate the tremorogenic muscles out-of-phase. A displacement signal monitored with a transducer was filtered so as to be "tuned" to the tremor frequency at the wrist or elbow. The filtered signal was used to amplitude-modulate the electrical stimulation. The design process was based on measurements of the open-loop frequency response characteristics of the forearm and hand to stimulation of the elbow and wrist flexors and extensors in a number of subjects. These data allowed us to identify closed-loop configurations, which attenuated 2-5 Hz tremors substantially, while only minimally attenuating functional movements in the 0-1 Hz range. There was a fairly delicate balance between efficacy and the risk of instability. However, designs were identified that offered enough tremor suppression and adequate immunity to muscle/load variations for the technique to be considered seriously for clinical application.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf02368521

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 5

  1. Javidan, M.; Elek, J.; Prochazka, A. Tremor reduction by functional electrical stimulation. Neurol. 40:369; 1990.
  2. Morrice, B.L.; Lee, R.G.; Becker, W.J.; White, D.G.; Hoffer, J.A. Viscous loading improves manual tracking accuracy in humans with cerebellar incoordination. Soc. Neurosci. Abstracts 13:1700; 1987.
  3. Mortimer, J.T. Motor prostheses. In: Brooks, V.B., ed. American handbook of physiology II, Section I: Motor control. Baltimore, MD: Williams and Wilkins; 1981: pp. 155–187.
  4. Stein, R.B.; Prochazka, A.; Popovic, D.; Edamura, M.; Llewellyn, M.; Davis, L.A. Technology transfer and development for walking using functional electrical stimulation. In: Popovic, D., ed., Advances in external control of human extremities X. Belgrade: Yugoslav Committee for Electronics and Automation; 1990: pp. 161–175.
  5. Wood, R.C. Automatic linear control system analysis and design software. Los Angeles, CA: West Educational Publishing Co.; 1988.

Cited by

See all 150

Metadata

Authors
Prochazka, A., Elek, J., & Javidan, M.
Affiliations
  • University of Bonn (DE)
  • University of Alberta (CA)
Venue
Annals of Biomedical Engineering
Published
1992-03
Volume
20
Issue
2
Pages
205-224
ISSN
  • 0090-6964 (ISSN-L)
  • 1573-9686
OpenAlex
W2093029239
Cited by
150
References
16
Citations by year
2026: 2 · 2025: 5 · 2024: 7 · 2023: 8 · 2022: 7 · 2021: 10 · 2020: 8 · 2019: 5 · 2018: 5 · 2017: 5 · 2016: 7 · 2015: 13 · 2014: 8 · 2013: 10 · 2012: 4
FWCI
1.25
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
pathological tremor, functional electrical stimulation, feedback control, tremor suppression, amplitude modulation, frequency response
MeSH terms
Electric Stimulation, Forearm, Humans, Isometric Contraction, Movement, Muscles, Reference Values, Tremor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.