In this study we evaluated a technique for tremor suppression with functional electrical stimulation (FES), the technical details of which were described in the previous paper. Three groups of patients were investigated: those with essential tremor, parkinsonian tremor, and cerebellar tremor associated with multiple sclerosis. In each group, tremor was attenuated by significant amounts (essential tremor: 73%; parkinsonian tremor: 62%; cerebellar tremor: 38%). These attenuations were in good accord with predictions based on the dynamic analyses and filter designs derived in the previous paper. With filters "tuned" to the lower mean tremor frequency encountered in the cerebellar patients, more attenuation was possible in this group as well. We identified some practical limitations in the clinical application of the technique in its present form. The most important was that in daily use, only one antagonist pair of muscles can realistically be controlled. At first sight, this restricts the usefulness of the system to patients with single-joint tremors. However, the concomitant use of mechanical orthoses may broaden the scope of application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A number of works show how adequate inertial (mass) loading of the tremulous limb reduces the amplitude of most types of tremor [18,19]”
From A neuroprosthesis for tremor management through the control of muscle co-contraction (2013) · cites this paper as [18]
In the citing paper
“Although tremor in one patient did not decreased, the device achieved an average suppression of 58.1 ± 20.5% (in a range between 91 and 10%) in the rest of the patients.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [64]
Citations
Cites
(1984) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06757-2 · Cited by 213
Lee, R. G., & Stein, R. B. (1981) · Annals of Neurology · doi:10.1002/ana.410100606 · Cited by 205
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 7×
“I N T R O D U C T I O N In the prev ious p a p e r (7) we descr ibed a new m e t h o d for select ively a t t enua t i ng t r e m o r by using c losed- loop func t iona l e lectr ical s t imu la t ion (FES) to ac t iva te the t r emorogen ic muscles ou t -o f -phase .”
BackgroundMethodSelf-citationOrigins of normal and pathological tremor
Marsden, C. D. (1984) · Movement Disorders: Tremor · doi:10.1007/978-1-349-06757-2_4 · Cited by 142
AN INVESTIGATION INTO THE VALUE OF TREATING INTENTION TREMOR BY WEIGHTING THE AFFECTED LIMB
HEWER, R. L., COOPER, R., & MORGAN, M. H. (1972) · Brain · doi:10.1093/brain/95.3.579 · Cited by 112 · cited 1×
“The po ten t i a l advan t age o f such a system is tha t it does not rely on mechanical loading o f the ext remity (2), nor on external ly powered e l ec t romechan ica l devices (6).”
BackgroundTHE ROLE OF REFLEXES IN THE RESTING TREMOR OF PARKINSON'S DISEASE
RACK, P. M. H., & ROSS, H. F. (1986) · Brain · doi:10.1093/brain/109.1.115 · Cited by 89
Freund, H., Hefter, H., Hömberg, V., & Reiners, K. (1984) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06757-2_12 · Cited by 11
Research works printed but not linked: 4
- Javidan, M.; Elek, J.; Prochazka, A. Tremor reduction by functional electrical stimulation. Neurology 40:369; 1990.
- Morrice, B.L.; Lee, R.G.; Becker, W.J.; White, D.G.; Hoffer, J.A. Viscous loading improves manual tracking accuracy in humans with cerebellar incoordination. Soc. Neurosci. Abstracts 13:1700; 1987.
- Prochazka, A.; Davis, L.; Gauthier, M. New intramuscular electrodes and microprocessor control of electrical stimulation to improve hemiparetic gait. Soc. Neurosci. Abstracts. 17:1468; 1991.
- Stein, R.B.; Prochazka, A.; Popovic, D.; Edamura, M.; Llewellyn, M.; Davis, L.A. Technology transfer and development for walking using functional electrical stimulation. In: D. Popovic, ed. Advances in external control of human extremities X. Belgrade: Yugoslav Committee for Electronics and Automation; 1990: pp. 161–176.
Cited by
Prochazka, A., Gauthier, M., Wieler, M., & Kenwell, Z. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90426-3 · Cited by 250
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150
Self-citationElectrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129
“The first FES system that was designed to suppress tremor was proposed 20 years ago [6, 15].”
BackgroundOnline tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
“As in the majority of previous tremor suppression studies based on FES [15], [16], [19] the stimulation was delivered out of phase with the estimated tremorogenic activity.”
BackgroundResultComparison of natural and artificial control of movement
Procházka, A. (1993) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.242403 · Cited by 109
Metadata
- Authors
- Javidan, M., Elek, J., & Prochazka, A.
- Affiliations
- University of Alberta (CA)
- University of Bonn (DE)
- Venue
- Annals of Biomedical Engineering
- Published
- 1992-03
- Volume
- 20
- Issue
- 2
- Pages
- 225-236
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2166205679
- Cited by
- 80
- References
- 7
- Citations by year
- 2025: 2 · 2024: 5 · 2023: 5 · 2022: 8 · 2021: 11 · 2020: 3 · 2018: 2 · 2017: 4 · 2016: 1 · 2015: 8 · 2014: 4 · 2013: 5 · 2012: 2
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- functional electrical stimulation, tremor suppression, essential tremor, parkinsonian tremor, cerebellar tremor, multiple sclerosis, orthoses, clinical evaluation
- MeSH terms
- Adult, Cerebellar Diseases, Data Interpretation, Statistical, Electric Stimulation Therapy, Female, Humans, Male, Middle Aged, Movement, Multiple Sclerosis, Parkinson Disease, Pilot Projects, Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Attenuation of pathological tremors by functional electrical stimulation II: Clinical evaluation. https://app.cochat.ai/papers/10.1007/bf02368522
- The paper
- Javidan, M., Elek, J., & Prochazka, A. (1992). Attenuation of pathological tremors by functional electrical stimulation II: Clinical evaluation. Annals of Biomedical Engineering. https://doi.org/10.1007/bf02368522
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.