The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
High-quality recording of bioelectric events: Part 2 Low-noise, low-power multichannel amplifier design
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
Principles of Applied Biomedical Instrumentation.
(1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-83-6-924_2 · Cited by 561
Driven-right-leg circuit design
Winter, B. B., & Webster, J. G. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325168 · Cited by 443
High-quality recording of bioelectric events: Part 1 Interference reduction, theory and practice
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 427
Self-citation60-Hz Interference in Electrocardiography
Huhta, J. C., & Webster, J. G. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324169 · Cited by 412
Electrocardiograms that represent the potential variations of a single electrode
Wilson, F. N., Johnston, F. D., Macleod, A. G., & Barker, P. S. (1934) · American Heart Journal · doi:10.1016/s0002-8703(34)90093-4 · Cited by 346
Skin impedance from 1 Hz to 1 MHz
Rosell, J., Colominas, J., Riu, P., Pallas-Areny, R., & Webster, J. G. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.4599 · Cited by 343
Binnie, C. B. (1989) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.52.9.1118 · Cited by 272
Scanlan, J. O. (1973) · Electronics and Power · doi:10.1049/ep.1973.0635 · Cited by 215
Motchenbacher, C. D., & Fitchen, F. C. (1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 208
Ground-Free ECG Recording with Two Electrodes
Thakor, N. V., & Webster, J. G. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326595 · Cited by 143
Duffy, F. H. (1982) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1982.tb50791.x · Cited by 92
A Low-Cost Multichannel Preamplifier for Physiological Signals
Smit, H. W., Verton, K., & Grimbergen, C. A. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326092 · Cited by 36
Self-citationLow-power, low-noise instrumentation amplifier for physiological signals
Hamstra, G. H., Peper, A., & Grimbergen, C. A. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442756 · Cited by 34
Self-citation
Cited by
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
The effects of electrode impedance on data quality and statistical significance in ERP recordings
Kappenman, E. S., & Luck, S. J. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01009.x · Cited by 447
Voytek, B. (2010) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2010.00191 · Cited by 406
Metadata
- Authors
- Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 1991-07
- Volume
- 29
- Issue
- 4
- Pages
- 433-440
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2089475953
- Cited by
- 450
- References
- 14
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.