Visual sensations produced by intracortical microstimulation of the human occipital cortex
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Penetrating electrodes require much less current to evoke phosphenes, on the order of microamps (Bak et al., 1990).”
From Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans (2020) · cites this paper as Bak et al., 1990
In the citing paper
“Furthermore, phosphene size, stimulation threshold (defined as the minimum current to produce a visible phosphene 50% of the time) and brightness depend on stimulation parameters such as the pulse width, train length, amplitude, and frequency of stimulation (Bak et al., 1990; Schmidt et al., 1996; Winawer and Parvizi, 2016; Bosking et al., 2017; Niketeghad et al., 2020; Fernández et al., 2021).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Bak et al., 1990
In the citing paper
“Stimulation in V1 with intracortical electrodes is estimated to activate tens to thousands of neurons (Histed et al., 2009), resulting in the perception of often ‘featureless’ white dots of light with a circular shape (Brindley and Lewin, 1968; Bak et al., 1990; Schmidt et al., 1996; Niketeghad et al., 2020; Fernández et al., 2021).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Bak et al., 1990
In the citing paper
“In contrast to the findings by Schmidt et al., 1996, some studies have found accommodation over different time scales and sometimes no accommodation at all (Bak et al., 1990; Fernández et al., 2021; Bartlett et al., 1977; Dobelle and Mladejovsky, 1974).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Bak et al., 1990
In the citing paper
“However, more elongated shapes and more complex shapes have been reported as well (Bosking et al., 2017; Winawer and Parvizi, 2016; Bak et al., 1990).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Bak et al., 1990
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Anatomy and physiology of a color system in the primate visual cortex
Livingstone, M., & Hubel, D. (1984) · The Journal of Neuroscience · doi:10.1523/jneurosci.04-01-00309.1984 · Cited by 1,628
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Handbook of Sensory Physiology
Newell, F. W. (1973) · American Journal of Ophthalmology · doi:10.1016/0002-9394(73)90115-3 · Cited by 986
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Dobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Self-citationParylene as a Chronically Stable, Reproducible Microelectrode Insulator
Loeb, G. E., Bak, M. J., Salcman, M., & Schmidt, E. M. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326115 · Cited by 258
Self-citation“Braille” reading by a blind volunteer by visual cortex stimulation
DOBELLE, W. H., MLADEJOVSKY, M. G., EVANS, J. R., ROBERTS, T. S., & GIRVIN, J. P. (1976) · Nature · doi:10.1038/259111a0 · Cited by 253
Self-citationActivated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227
An Exploration of the Ability of Macaques to Detect Microstimulation of Striate Cortex
Bartlett, J. R., & Doty, R. W. (1980) · Springer eBooks · doi:10.1007/978-94-009-8225-3_4 · Cited by 109
Sensory Effects of Electrical Stimulation of the Visual and Paravisual Cortex in Man
Brindley, G. S. (1973) · Handbook of sensory physiology · doi:10.1007/978-3-642-65495-4_14 · Cited by 89
Research works printed but not linked: 1
- Brindley, G. S. (1982) Visual prostheses.Human neurobiol.,1, 281–283.
Cited by
Items 201–300 of 300
Lee, S. W., & Fried, S. I. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0019 · Cited by 5
“Most of these prostheses use implantable microelectrodes to deliver electric stimulation to V1, and much previous work has shown that such an approach can elicit the perception of small light dots, referred to as phosphenes, in animal experiments [7,8] and in clinical testing [1,3,4,9].”
BackgroundLiang, T., Zhao, L., Sui, X., Zhou, C., Ren, Q., & Qi, Y. (2010) · Ophthalmic Research · doi:10.1159/000317034 · Cited by 7
Introduction to Visual Prostheses
Fernández, E., & Normann, R. A. (2016) · Europe PMC (PubMed Central) · Cited by 12
Microelectrode coatings for neural stimulation and recording
Cogan, S. F. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280988 · Cited by 7
A proposed intracortical visual prosthesis image processing system
Srivastava, N., & Troyk, P. R. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615667 · Cited by 8
Delbeke, J., & Veraart, C. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd325 · Cited by 7
A Compatible Electrocutaneous Display for functional Magnetic Resonance Imaging application
Hartwig, V., Cappelli, C., Vanello, N., Ricciardi, E., Scilingo, E. P., Giovannetti, G., Santarelli, M. F., Positano, V., Pietrini, P., Landini, L., et al. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260279 · Cited by 6
The Bionic Eye: Retinal Prostheses
Park, R. I. (2004) · International Ophthalmology Clinics · doi:10.1097/00004397-200404440-00011 · Cited by 6
“Bak et al, at the National Institutes of Health (NIH), tested the feasibility of a cortical microstimulation by implanting 38 electrodes into the occipital cortex of a patient.(8) The patient reported phosphenes that varied with stimulus amplitude, frequency, and duration.”
BackgroundEvaluation of micro-electrocorticographic electrodes for electrostimulation
Wilks, S. J., Koivuniemi, A. S., Thongpang, S., Williams, J. C., & Otto, K. J. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333178 · Cited by 8
Commentary: Injecting Instructions into Premotor Cortex
Lebedev, M., & Ossadtchi, A. E. (2018) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2018.00065 · Cited by 6
“…areas in humans, such as S1 (Cushing, 1909; Penfield and Boldrey, 1937; Penfield and Rasmussen, 1950; Flesher et al., 2016) and primary visual cortex (Brindley, 1970; Dobelle and Mladejovsky, 1974; Bak et al., 1990), the focus has been traditionally on the perceptions experienced by the subjects.”
BackgroundGrill, W. M., & Kirsch, R. F. (1999) · Wiley eBooks · doi:10.1002/047134608x.w1424 · Cited by 8
Towards precise synthetic neural codes: high-dimensional stimulation with flexible electrodes
Kim, R., Liu, Y., Zhang, J., Xie, C., & Luan, L. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00447-y · Cited by 7
“However, for decades after the discovery of this phenomenon, the number of phos-phenes that could be reliably induced in a single subject remained low, limiting the ability to construct detailed shapes or patterns 57,104 .”
End-to-end learning of safe stimulation parameters for cortical neuroprosthetic vision
Küçükoğlu, B., Rueckauer, B., van Steveninck, J. D. R., van der Grinten, M., Güçlütürk, Y., Roelfsema, P. R., Güçlü, U., & van Gerven, M. A. J. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ade918 · Cited by 7
“The resulting current going beyond the order of milliamperes can cause seizures upon simultaneous stimulation of multiple electrodes (Fernandez et al 2021), whereas current on the order of microamperes suffices to evoke phosphenes with penetrating electrodes (Bak et al 1990, Beauchamp et al 2020).”
Low Frequency Microstimulation Is Locally Excitatory in Patients With Epilepsy
Bartoli, A., Tyrand, R., Vargas, M. I., Momjian, S., & Boëx, C. (2018) · Frontiers in Neural Circuits · doi:10.3389/fncir.2018.00022 · Cited by 5
“It has been since applied either for behavioral or for electrophysiological studies in animals (for a review see Bak et al., 1990; Histed et al., 2013).”
BackgroundA new current stimulator architecture for visual cortex stimulation
Osipov, D., Steffen Paul, A., Strokov, S., & Kreiter, A. K. (2015) · IEEE Nordic Circuits and Systems Conference (NorCAS) · doi:10.1109/norchip.2015.7364399 · Cited by 5
“The stimulation with the electrodes placed epicortically is less invasive and requires currents on the order of a few mA [1], [2].”
BackgroundThe Role of Electrode-Site Placement in the Long-Term Stability of Intracortical Microstimulation
Saldanha, R. L., Urdaneta, M. E., & Otto, K. J. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.712578 · Cited by 6
Findings from Chronic Optic Nerve and Cortical Stimulation
Schmidt, E. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0754-7_15 · Cited by 4
Self-citationA three-dimensional microassembly structure for micromachined planar microelectrode arrays
Ghovanloo, M., & Najafi, K. (2005) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2005.1548398 · Cited by 5
“current thresholds needed for intracortical stimulation are one to two orders of magnitude lower than those needed by surface electrodes [6].”
BackgroundMobility enhancement using simulated artificial human vision
Dowling, J. (2007) · Cited by 7
Intracortical microstimulation in humans: a decade of safety and efficacyPreprint
Greenspon, C. M., Hobbs, T. G., Verbaarschot, C., Alamri, A. H., Shelchkova, N. D., Lienkämper, R., Ye, J., Simpson, T. W., Weiss, J. M., Weir, D. M., et al. (2025) · medRxiv · doi:10.1101/2025.08.11.25332271 · Cited by 5
“Beyond somatosensation, ICMS may also restore other lost senses, such as vision for patients with retinal or subcortical visual impairments 10,11 .”
Neyazi, B., Schwabe, K., Alam, M., Krauss, J. K., & Nakamura, M. (2016) · Journal of Chemical Neuroanatomy · doi:10.1016/j.jchemneu.2016.06.004 · Cited by 4
Overstreet, C. K., Hellman, R. B., Wong, R. D. P., Santos, V. J., & Tillery, S. I. H. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00091 · Cited by 4
“However, the repetition, order, and timing of stimulation on nearby electrodes can modify the sensations perceived in response to stimulation on a single electrode (Penfield and Boldrey, 1937; Penfield and Welch, 1949; Bak et al., 1990; Schmidt et al., 1996; Tehovnik et al., 2005).”
BackgroundMultichannel stimulation module as a tool for animal studies on cortical neural prostheses
Hayashida, Y., Kameda, S., Umehira, Y., Ishikawa, S., & Yagi, T. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.927581 · Cited by 5
Effects of Transcranial Electrical Stimulation on Sensory Functions
Chaieb, L., Saiote, C., Paulus, W., & Antal, A. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-404704-4.00007-7 · Cited by 4
Image acquisition and reduction dedicated to a visual implant
Harvey, J. F., & Sawan, M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.657014 · Cited by 4
Weitz, A. C., & Weiland, J. D. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_7 · Cited by 4
Normann, R. A., Warren, D. J., & Koulakov, A. A. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196763 · Cited by 4
Development of Microelectronic Visual Implants
Gerding, H., Taneri, S., Uhlig, C. E., & Krause, K. (2001) · Medical radiology · doi:10.1007/978-3-642-56439-0_7 · Cited by 5
Interfacing Microelectronics and the Human Visual System
Agrawal, R. N., Humayun, M. S., Weiland, J. D., Lazzi, G., & Gosalia, K. C. (2005) · doi:10.1201/9781420037715-22 · Cited by 4
Local field potential phase modulates the evoked response to electrical stimulation in visual cortex
Allison-Walker, T., Hagan, M. A., Meikle, S. J., Price, N. S. C., & Wong, Y. T. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada828 · Cited by 3
Schelles, M., Lievens, W., Goyvaerts, L., Ceyssens, F., Muller, R., & Kraft, M. D. (2025) · IEEE Access · doi:10.1109/access.2025.3581460 · Cited by 4
“Electrical stimulation and recording has been in use for decades to interact with the human body for all kinds of medical applications [1], [2], [3], [4], [5], [6], [7].”
Lozano, A., Chen, X., Grouw, M. L., Li, B., Wang, F., van der Grinten, M., Soto‐Sánchez, C., Morales-Gregorio, A., Fernández, E., & Roelfsema, P. R. (2025) · Brain stimulation · doi:10.1016/j.brs.2025.103019 · Cited by 6
The electrode—principles of the neural interface and materials
Merrill, D. R., & Stecker, M. M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-817000-7.00007-7 · Cited by 3
A Real-Time and Portable Bionic Eye Simulator
Josh, H., Yong, B., & Kleeman, L. (2013) · Communications in computer and information science · doi:10.1007/978-3-642-38256-7_4 · Cited by 3
Wiedmann, R., Rosahl, S. K., Brinker, T., Samii, M., & Nakamura, M. (2013) · Experimental Brain Research · doi:10.1007/s00221-013-3623-0 · Cited by 3
Colour Vision: Cortical Circuitry for Appearance
Wandell, B. A. (2008) · Current Biology · doi:10.1016/j.cub.2008.01.045 · Cited by 3
8-Channel Neural Stimulation ASIC for Epidural Visual Cortex Stimulation
Osipov, D., Strokov, S., Kreiter, A. K., Schander, A., Tessmann, T., Lang, W., & Paul, S. (2017) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126617400084 · Cited by 3
Bianco, M. G., Pullano, S. A., Critello, C. D., Menniti, M., Citraro, R., Russo, E., Sarro, G. D., & Fiorillo, A. S. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438766 · Cited by 3
“Such devices are referred to as brainmachine interfaces (BMIs) [1]-[3].”
BackgroundNeuroprosthetic Interfaces – The Reality Behind Bionics and Cyborgs
Loeb, G. E. (2011) · Brill | mentis eBooks · doi:10.30965/9783957438843_015 · Cited by 3
“Initial efforts to stimulate the visual area of the cerebral cortex were encouraging (Brindley and Lewin, 1968; Bak et al., 1990) but were largely abandoned as the large technical challenges became apparent (Normann et al., 1996).”
BackgroundSelf-citationTest Setup for Supporting Human Implantation of Intracortical Visual Prosthesis Device
Srivastava, N., Troyk, P. R., Dagnelie, G., & Bradley, D. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369704 · Cited by 3
“It was demonstrated that currents to elicit phosphenes by intracortical microstimulation are ten to hundred times lower than those by non-penetrating electrodes [6].”
BackgroundCORTICAL VISUAL NEUROPROSTHESES FOR THE BLIND
Fernández, E., Pelayo, F. J., Ahnelt, P. K., Ammermüller, J., & Normann, R. A. (2004) · Cited by 7
Dagnelie, G., Stronks, H. C., & Barry, M. P. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-398358-9.00069-0 · Cited by 3
Direct Current Block of Peripheral Nerve: Electrode and Waveform Development
Vrabec, T. L. (2016) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
HV compliant current driver with on-chip read-out protection switch for neural stimulation
Osipov, D., Strokov, S., Kreiter, A. K., Schander, A., Tessmann, T., Lang, W., & Steffen Paul, A. (2017) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-017-1022-3 · Cited by 3
“placed epicortically is less invasive, but requires currents on the order of a few mA [1, 2].”
BackgroundTHE EMERGING WORLD OF MOTOR NEUROPROSTHETICS: A NEUROSURGICAL PERSPECTIVE
Leuthardt, E. C., Schalk, G., Moran, D. W., & Ojemann, J. G. (2006) · Neurosurgery · doi:10.1227/01.neu.0000243275.01470.c0 · Cited by 6
Sense Element Engagement Theory Explains How Neural Networks Produce Cortical Prosthetic VisionPreprint
Pavloski, R. (2021) · doi:10.36227/techrxiv.17161187 · Cited by 1
“present, direct cortical stimulation during neurosurgery and stimulation controlled by video images have been used to produce multiple distinct phosphenes each of which is experienced as occupying a continuous region in visual space [13],[16],[17],[18],[19],[20],[21],[22].”
MethodLarge-scale RF mapping without visual input for neuroprostheses in macaque and human visual cortexPreprint
Lozano, A., Chen, X., Grouw, M. L., Li, B., Wang, F., van der Grinten, M., Soto‐Sánchez, C., Morales-Gregorio, A., Fernández, E., & Roelfsema, P. R. (2024) · medRxiv · doi:10.1101/2024.12.22.24319047 · Cited by 3
Long-term safety and efficacy of intracortical microstimulation in humans
Greenspon, C. M., Hobbs, T. G., Verbaarschot, C., Alamri, A. H., Shelchkova, N. D., Lienkämper, R., Ye, J., Simpson, T. W., Weiss, J. M., Weir, D., et al. (2026) · Science Translational Medicine · doi:10.1126/scitranslmed.aec3728 · Cited by 8
Pavloski, R. P., & Lamb, C. (2017) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2017.7965917 · Cited by 3
“A single phosphene is clearly a unified visual percept, and separating stimulating electrodes sufficiently produces two distinct phosphene percepts [7, 8].”
BackgroundMethodStrokov, S., Schander, A., Stemmann, H., Tebmann, T., Lang, W., & Kreiter, A. K. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8234432 · Cited by 3
“It has been shown that phosphenes induced by intracortical stimulation have higher resolution than those induced by surface electrodes [1].”
BackgroundMethodChronic thresholds for evoking perceptual responses in the rat sensory cortex
Brunton, E., Yan, E. B., Gillespie-Jones, K. L., Lowery, A. J., & Rajan, R. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146669 · Cited by 2
“In contrast, penetrating intra-cortical electrodes use lower currents and voltages to stimulate the input layer of the visual cortex to generate phosphene-based perception [7].”
BackgroundA low-power digitally closed-loop electrical stimulator suited for low-pulse-width-stimulation
Ranjandish, R., & Shoaei, O. (2015) · Iranian Conference on Electrical Engineering · doi:10.1109/iraniancee.2015.7146437 · Cited by 2
“The simplest way to implement such a stimulator is presented in [9].”
Humayun, M. S., Lakhanpal, R. R., & Weiland, J. D. (2006) · Elsevier eBooks · doi:10.1016/b978-0-323-02598-0.50160-9 · Cited by 2
Legéndy, C. R. (2009) · Springer eBooks · doi:10.1007/978-0-387-88849-1 · Cited by 6
Visual prostheses and other assistive devices
Memon, M. A., & Rizzo, J. F. (2010) · Elsevier eBooks · doi:10.1016/b978-0-7020-2983-7.00075-9 · Cited by 2
Millisecond Imaging of Neural Responses to Micro-stimuli in the Visual Cortex Layer II/III In Vitro
Hayashi, S., Yoshida, K., Nomoto, T., Tanaka, Y., Yagi, T., & Hayashida, Y. (2020) · IEEE Global Conference on Life Sciences and Technologies (LifeTech) · doi:10.1109/lifetech48969.2020.1570619123 · Cited by 2
“In clinical trials as well as psychophysical studies in non-human primates on the intra-cortical visual prosthesis, repetitive current pulses at 100-200 Hz of the microstimulation have been used to induce localized phosphenes [3][4][5].”
MethodOn the use of time division multiplexing to improve electrical brain stimulation focality
Abouelseoud, G., Abouelseoud, Y., Shoukry, A., Ismail, N. E., & Mekky, J. F. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102048 · Cited by 2
Gebrehiwot, A. N., Kato, T., & Nakazawa, K. (2021) · PLoS ONE · doi:10.1371/journal.pone.0249996 · Cited by 3
“Offering a larger surface area to activate, intracortical microsimulation (ICMS) efficiently produces phosphenes at lower currents compared to surface electrodes [16,17].”
BackgroundA mixed integer linear programming framework for improving cortical vision prosthesis designs
Abouelseoud, G., Abouelseoud, Y., Shoukry, A., Ismail, N. E., & Mekky, J. F. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104253 · Cited by 2
Spatial resolution of local field potential signals in macaque V4
Foroushani, A. N., Neupane, S., Pastor, P. D. H., Pack, C. C., & Sawan, M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7321 · Cited by 4
“The functionality of these devices relies on the hope to localize multiple phosphenes in the visual field by electrically stimulating multiple implanted electrodes in the visual cortex [4-9].”
BackgroundMaterials for Implantable Electrodes and Electronic Devices
Campbell, P. K., & Jones, K. E. (2006) · Materials Science and Technology · doi:10.1002/9783527603978.mst0169 · Cited by 2
Bipolar intracortical microstimulation expands the repertoire of neuronal activation patterns
Schelles, M., Verhaege, A., Rompaey, N. V., Goyvaerts, L., Wierda, K. D. B., Ceyssens, F., Kraft, M. D., & Bonin, V. (2026) · Journal of Neural Engineering · doi:10.1101/2025.03.21.644593 · Cited by 3
New Applications of Neurotechnologies for Neurological Disorders
Orsborn, A. L., Pirondini, E., Capogrosso, M., Gaunt, R. A., & Stavisky, S. D. (2025) · Springer eBooks · doi:10.1007/978-3-031-89307-0_25 · Cited by 1
Fukuda, S., & Hayashida, Y. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1710221 · Cited by 1
“(Bak et al., 1990; Schmidt et al., 1996; Flesher et al., 2016; Armenta Salas et al., 2018).”
Kozai, T. D. Y., Hooks, B. M., Vazquez, A. L., Gharbawie, O. A., Huang, C., Graczyk, E. L., Smith, M. A., Taylor, D. M., Hernandez-Reynoso, A. G., London, A. J., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae54cf · Cited by 4
“Behavioral psycho-physics provides a critical anchor for this coordination, linking stimulation parameters and neural recruitment to reported tactile or visual percepts [43, 44, 196] in ways that can be measured consistently whether the subject is a mouse, a primate, or a human.”
Impaired Vision: Visual Prosthesis
Girvin, J. P., & Martins, A. (2009) · Springer eBooks · doi:10.1007/978-3-540-69960-6_182 · Cited by 1
Self-citationTraining recurrent pulsed networks by genetic and Taboo methods
Gilson, M., Py, J. S., Brault, J., & Sawan, M. (2004) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2003.1226273 · Cited by 1
Osipov, D., & Steffen Paul, A. (2016) · IEEE International Symposium on Design and Diagnostics of Electronic Circuits & Systems (DDECS) · doi:10.1109/ddecs.2016.7482455 · Cited by 1
“Activation currents for the epicortical placement of stimulation electrodes are in order of a few mA [2], [3].”
BackgroundCoatings for Microneural Implants: Electrical Considerations
Olczak, K. P., & Otto, K. J. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_7 · Cited by 1
Intraocular Retinal Prostheses and Related Signal Processing
Scribner, D. A., Margalit, E., Eong, K. A., Weiland, J. D., de Juan, E., & Humayun, M. S. (2002) · Topics in biomedical engineering · doi:10.1007/978-1-4757-5865-8_4 · Cited by 1
Biophysics/ Engineering of Cortical Electrodes
Troyk, P. R. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0754-7_11 · Cited by 1
“The “hat pin” intracortical electrode design was developed by Salcman and Bak [39], and was used in several human visual prosthesis investigative experiments [4, 40].”
MethodOn “Visual Prosthesis” by Schiller and Tehovnik (2008)
Schmidt, E., Bak, M., Kufta, C. V., & Hambrecht, T. (2010) · Perception · doi:10.1068/p6467 · Cited by 1
“…Received 17 May 2009; in revised form 15 August 2009 doi:10.1068/p6467 In order to derive engineering design data for an intracortical visual prosthesis, acute microelectrode studies were performed in sighted patients undergoing occipital craniotomy for other reasons (Bak et al 1990).”
BackgroundSelf-citationPerceiving Electrical Stimulation of Identified Human Visual Areas
Murphey, D. K., Maunsell, J. H. R., Yoshor, D., & Beauchamp, M. (2009) · NeuroImage · doi:10.1016/s1053-8119(09)70632-9 · Cited by 2
NEURAL PROSTHETIC INTERFACES BETWEEN NEURAL AND ELECTRONIC COMPUTING
Loeb, G. E. (1993) · Elsevier eBooks · doi:10.1016/b978-0-444-89958-3.50017-6 · Cited by 1
Self-citationSense Element Engagement Theory Explains How Neural Networks Produce Cortical Prosthetic VisionPreprint
Pavloski, R. P. (2021) · doi:10.36227/techrxiv.17161187.v1 · Cited by 1
Regele, O. B. (2013) · Purdue e-Pubs (Purdue University System)
Neuroprótesis visuales intracorticales
Vicente, J. M. F., Álvarez, J. J. M., Guerrero, F. J. G., Fernández, E., & Moreo, F. J. T. (2007) · Digital Repository (Polytechnic University of Cartagena)
Eye Movements by Striate Cortex Phosphene Induction and the Generation of Saccadic
Slocum, W. M., Carvey, C. E., Schiller, P. H., Manzur, H., Alvarez, J., Babul, C., Maldonado, P., Happel, M. F. K., Deliano, M., Handschuh, J., et al. (2015)
A Modular 32-Site Wireless Neural
Ghovanloo, M., & Najafi, K. (2004)
Why is Sentience so Hardly Explicable?Preprint
Navon, D. (2016) · SSRN Electronic Journal · doi:10.2139/ssrn.2795688
Gall, C., & Sabel, B. A. (2012) · Cambridge University Press eBooks · doi:10.1017/cbo9781139136907.011
The Development of a Retinal Prosthesis: A Significant Biomaterials Challenge
Humayun, M. S., Rowley, A. P., Whalen, J. J., Weiland, J. D., & Tanguay, A. R. (2012) · Elsevier eBooks · doi:10.1016/b978-0-08-087780-8.00081-4
Developing a cortically-based visual prosthesis for the blind in a chronic nonhuman primate model
Davis, T. S. (2013) · J. Willard Marriott Library · doi:10.26053/0h-c2vz-1e00
Smiley, S. (2014) · uO Research (University of Ottawa) · doi:10.20381/ruor-3832
“Cortical implants demonstrated some success in allowing blind patients to perceive phosphenes, or flashes of light (Bak et al., 1990; Dobelle, 2000; Wyatt & Rizzo, 1996).”
BackgroundCurrent Advances in the Design of Retinal and Cortical Visual Prostheses
Bareket, L., Barriga‐Rivera, A., Rosenfeld, J. V., Lovell, N. H., & Suaning, G. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812539-7.00005-2
Humayun, M. S., Brant, R., & Weiland, J. D. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4557-0737-9.00126-0
Cortical Somatosensory Neuroprosthesis for Active Tactile Exploration without Visual Feedback
An, J. H. (2013) · DukeSpace (Duke University)
Andresen, M. C. (2009) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.1163675.625447
Interfacing Microelectronics and the Human Visual System
Lazzi, G., Humayun, M. S., Gosalia, K. C., Weiland, J. D., & Agrawal, R. N. (2005) · CRC Press eBooks · doi:10.1201/9781420037715.ch17
Dagnelie, G., Weiland, J. D., Sadda, S. R., & Eong, K. A. (2002) · Elsevier eBooks · doi:10.1016/b978-012436636-7/50215-9
Ortega, A. M. L. (2022) · Digital Repository (Polytechnic University of Cartagena) · doi:10.31428/10317/11200
Investigation of Audio Controlled Edge Semantic Segmentation System for Visually Impaired People
Wang, Y., Wang, Z., Hahn, N., Cheng, L., & Liu, S. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11252696
Charge Pumps for Implantable Microstimulators in Low and High-Voltage Technologies
Kar, G. C. (2013) · PolyPublie (École Polytechnique de Montréal)
Apport des dispositifs de restauration de la vision et de la résolution temporelle
Poujade, M. (2019) · theses.fr (ABES) · doi:10.70675/36673ad1zae20z4163zabbfz33afe4422dd6 · Cited by 1
From adaptation mechanisms with visual impairment to new technologies in vision restoration
Kime, S. (2016) · theses.fr (ABES) · doi:10.70675/a5e5f10fzf01cz40d1za5f2z5067b3e0d7b1
Poulkouras, R. (2022) · theses.fr (ABES) · doi:10.70675/18e3c078z78a1z4e5czbd7dz301fcc213f06
Negri, F., Guggenmos, D. J., & Barban, F. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae5f4b
“…and neuropsychiatric disorders often through deep brain stimulation [4–6], the restoration of sensory perception in patients with disabilities [7–10], the provision of sensory feedback for neuroprostheses [11, 12], and the enhancement of plasticity to facilitate post-injury cortical rewiring…”
Metadata
- Authors
- Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M.
- Affiliations
- National Institutes of Health (US)
- Western University (CA)
- Queen's University (CA)
- ORCID
- Loeb, G. E.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 1990-05
- Volume
- 28
- Issue
- 3
- Pages
- 257-259
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2015584838
- Cited by
- 299
- References
- 13
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 6 · 2023: 6 · 2022: 14 · 2021: 11 · 2020: 16 · 2019: 5 · 2018: 12 · 2017: 10 · 2016: 13 · 2015: 8 · 2014: 8 · 2013: 16 · 2012: 11
- FWCI
- 0.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- intracortical microstimulation, visual sensation, occipital cortex, visual perception, human visual cortex, cortical stimulation
- MeSH terms
- Electric Stimulation, Electrodes, Implanted, Humans, Phosphenes, Vision, Ocular, Visual Cortex, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.