Parylene as a Chronically Stable, Reproducible Microelectrode Insulator
Abstract
One of the major problems in the design of neurophysiologiv extracellular microelectrodes is the application and selective removal of the insulation. In addition to the usual problems of achieving pin-hole-free coatings and reproducible tip exposures and impedances, chronic electrode designshave the additional requirement of maintaining megohm levels of electrical isolation for months in vivo. A method of insulating finely tapered microelectrodes with complicated shapes by vapor condensation of Parylene-C is presented, along with a method for exposing controlled, reproducible lengths of their tips. In vivo and in vitro impedance tests and unit records obtained over 100 days in monkey motor cortex are presented. The electric arc process used to expose Parylene-covered iridium and tungsten microelectrodes is found to give cleaner recording surfaces with impedances lower than those obtainable with previously described methods. Chronic iridium microelectrodes so fabricated have recorded unit potentials and maintained constant impedances for over 4 months in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johnson, A. P. (2024) · Being and Becoming Teachers of Writing · doi:10.4324/9781003334798-34 · Cited by 4,502
Tungsten Microelectrode for Recording from Single Units
Hubel, D. H. (1957) · Science · doi:10.1126/science.125.3247.549 · Cited by 849
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464
Another tungsten microelectrode
Levick, W. R. (1972) · Medical & Biological Engineering · doi:10.1007/bf02474199 · Cited by 376
A Simple Microelectrode for recording from the Central Nervous System
GREEN, J. D. (1958) · Nature · doi:10.1038/182962a0 · Cited by 309
Glass Insulated Platinum Microelectrode
Wolbarsht, M. L., MacNichol, E. F., & Wagner, H. G. (1960) · Science · doi:10.1126/science.132.3436.1309 · Cited by 305
Gesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. H. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287156 · Cited by 301
Dowben, R. M., & Rose, J. E. (1953) · Science · doi:10.1126/science.118.3053.22 · Cited by 196
Cited by
Forces produced by medial gastrocnemius and soleus muscles during locomotion in freely moving cats.
Walmsley, B., Hodgson, J. A., & Burke, R. E. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.5.1203 · Cited by 722
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Self-citationFailure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Dum, R. P., & Strick, P. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.3902-04.2005 · Cited by 556
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Metadata
- Authors
- Loeb, G. E., Bak, M. J., Salcman, M., & Schmidt, E. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1977-03
- Volume
- BME-24
- Issue
- 2
- Pages
- 121-128
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2140774760
- Cited by
- 258
- References
- 26
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parylene as a Chronically Stable, Reproducible Microelectrode Insulator. https://app.cochat.ai/papers/10.1109/tbme.1977.326115
- The paper
- Loeb, G. E., Bak, M. J., Salcman, M., & Schmidt, E. M. (1977). Parylene as a Chronically Stable, Reproducible Microelectrode Insulator. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1977.326115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.