Marked improvement in HbA1c following commencement of flash glucose monitoring in people with type 1 diabetes
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Minimal evidence supports the efficacy of flash monitoring in lowering HbA 1c . We sought to assess the impact of introducing flash monitoring in our centre. We undertook a prospective observational study to assess change in HbA 1c in 900 individuals with type 1 diabetes following flash monitoring (comparator group of 518 with no flash monitoring). Secondary outcomes included changes in hypoglycaemia, quality of life, flash monitoring data and hospital admissions. Those with baseline HbA 1c ≥58 mmol/mol (7.5%) achieved a median −7 mmol/mol (interquartile range [IQR] −13 to −1) (0.6% [−1.2 to −0.1]%) change in HbA 1c ( p < 0.001). The percentage achieving HbA 1c <58 mmol/mol rose from 34.2% to 50.9% ( p < 0.001). Median follow-up was 245 days (IQR 182 to 330). Individuals not using flash monitoring experienced no change in HbA 1c across a similar timescale ( p = 0.508). Higher HbA 1c ( p < 0.001), younger age at diagnosis ( p = 0.003) and lower social deprivation ( p = 0.024) were independently associated with an HbA 1c fall of ≥5 mmol/mol (0.5%). More symptomatic (OR 1.9, p < 0.001) and asymptomatic (OR 1.4, p < 0.001) hypoglycaemia was reported after flash monitoring. Following flash monitoring, regimen-related and emotional components of the diabetes distress scale improved although the proportion with elevated anxiety (OR 1.2, p = 0.028) and depression (OR 2.0, p < 0.001) scores increased. Blood glucose test strip use fell from 3.8 to 0.6 per day ( p < 0.001). Diabetic ketoacidosis admissions fell significantly following flash monitoring ( p = 0.043). Flash monitoring is associated with significant improvements in HbA 1c and fewer diabetic ketoacidosis admissions. Higher rates of hypoglycaemia may relate to greater recognition of hitherto unrecognised events. Impact upon quality of life parameters was mixed but overall treatment satisfaction was overwhelmingly positive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In individuals with type 1 diabetes wearing isCGM devices, studies have shown improvement in A1C levels (41,77)”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [77]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Hospital Anxiety and Depression Scale
Zigmond, A. S., & Snaith, R. P. (1983) · Acta Psychiatrica Scandinavica · doi:10.1111/j.1600-0447.1983.tb09716.x · Cited by 47,139 · cited 8×
“CGM Continuous glucose monitoring CSII Continuous subcutaneous insulin infusion DAFNE Dose Adjustment for Normal Eating DDS Diabetes distress scale DKA Diabetic ketoacidosis HADS Hospital Anxiety and Depression Scale IQR Interquartile range IAH Impaired awareness of hypoglycaemia MDI Multiple daily injection NHS Natio…”
BackgroundInfluentialDepression and quality of life in older persons: A review
Sivertsen, H., Bjørkløf, G. H., Engedal, K., Selbæk, G., & Helvik, A.-S. (2015) · Dementia and Geriatric Cognitive Disorders · doi:10.1159/000437299 · Cited by 14,152
Assessing Psychosocial Distress in Diabetes
Polonsky, W. H., Fisher, L., Earles, J., Dudl, R. J., Lees, J., Mullan, J., & Jackson, R. A. (2005) · Diabetes Care · doi:10.2337/diacare.28.3.626 · Cited by 1,575
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Amiel, S. A., Beveridge, S., Bradley, C., Gianfrancesco, C., Heller, S. R., James, P., McKeown, N., Newton, D. F., Newton, L. D., Oliver, L., et al. (2002) · Deakin Research Online (Deakin University) · Cited by 723
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Dunn, T. C., Xu, Y., Hayter, G., & Ajjan, R. A. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.12.015 · Cited by 239 · cited 1×
“A previous study demonstrated a strong correlation between more flash monitoring scanning and lower estimated HbA1c [21]; in addition, we have shown increased scanning is prospectively associated with fall in HbA1c.”
Background
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
“In a retrospective study of adults with type 2 diabetes taking insulin, a reduction in acute diabetes-related events and all-cause hospitalizations was seen (74).”
Background7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Charleer, S., De Block, C., Van Huffel, L., Broos, B., Fieuws, S., Nobels, F., Mathieu, C., & Gillard, P. (2020) · Diabetes Care · doi:10.2337/dc19-1610 · Cited by 261
Metadata
- Authors
- Tyndall, V., Stimson, R. H., Zammitt, N. N., Ritchie, S. A., McKnight, J. A., Dover, A. R., & Gibb, F. W.
- Affiliations
- Western General Hospital (GB)
- Edinburgh Royal Infirmary (GB)
- Corresponding author
- Gibb, Fraser W.
- Venue
- Diabetologia
- Published
- 2019-06-09
- Volume
- 62
- Issue
- 8
- Pages
- 1349-1356
- ISSN
- 0012-186X (ISSN-L)
- 1432-0428
- PMC
- PMC6647076
- OpenAlex
- W2950215271
- Cited by
- 165
- References
- 24
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 20 · 2023: 18 · 2022: 29 · 2021: 50 · 2020: 32 · 2019: 4
- FWCI
- 23.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Diabetologia (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Edinburgh Research Explorer (University of Edinburgh) (submittedVersion, cc-by)
- Funders
- University of Edinburgh
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- flash glucose monitoring, type 1 diabetes, HbA1c, glycemic control, hypoglycemia, diabetic ketoacidosis, diabetes distress, depression, anxiety, blood glucose test strips, hospitalization, social deprivation, age at diagnosis, HbA1c targets, diabetes self-management, quality of life
- MeSH terms
- Adult, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Male, Middle Aged, Patient Admission, Prospective Studies, Quality of Life, Surveys and Questionnaires, Research Design, Blood Glucose Self-Monitoring, Diabetic Ketoacidosis, Treatment Outcome, Patient Satisfaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Marked improvement in HbA1c following commencement of flash glucose monitoring in people with type 1 diabetes. https://app.cochat.ai/papers/10.1007/s00125-019-4894-1
- The paper
- Tyndall, V., Stimson, R. H., Zammitt, N. N., Ritchie, S. A., McKnight, J. A., Dover, A. R., & Gibb, F. W. (2019). Marked improvement in HbA1c following commencement of flash glucose monitoring in people with type 1 diabetes. Diabetologia. https://doi.org/10.1007/s00125-019-4894-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.