Effect of flash glucose monitoring in adults with type 1 diabetes: a nationwide, longitudinal observational study of 14,372 flash users compared with 7691 glucose sensor naive controls
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Aims/hypothesis: The aim of this work was to evaluate changes in glycaemic control (HbA 1c ) and rates of severe hypoglycaemia over a 2 year period after initiation of flash glucose monitoring (FM) in type 1 diabetes. Methods: Using data from the Swedish National Diabetes Registry, 14,372 adults with type 1 diabetes with a new registration of FM during 2016–2017 and with continued FM for two consecutive years thereafter, and 7691 control individuals using conventional self-monitoring of blood glucose (SMBG) during the same observation period, were included in a cohort study. Propensity sores and inverse probability of treatment weighting (IPTW) were used to balance FM users with SMBG users. Changes in HbA 1c and events of severe hypoglycaemia were compared. Results: After the start of FM, the difference in IPTW change in HbA 1c was slightly greater in FM users compared with the control group during the follow-up period, with an estimated mean absolute difference of −1.2 mmol/mol (−0.11%) (95% CI −1.64 [−0.15], −0.75 [−0.07]; p < 0.0001) after 15–24 months. The change in HbA 1c was greatest in those with baseline HbA 1c ≥70 mmol/mol (8.5%), with the estimated mean absolute difference being −2.5 mmol/mol (−0.23%) (95% CI −3.84 [−0.35], −1.18 [−0.11]; p = 0.0002) 15–24 months post index. The change was also significant in the subgroups with initial HbA 1c ≤52 mmol/mol (6.9%) and 53–69 mmol/mol (7.0–8.5%). Risk of severe hypoglycaemic episodes was reduced by 21% for FM users compared with control individuals using SMBG (OR 0.79 [95% CI 0.69, 0.91]; p = 0.0014)]. Conclusions/interpretation: In this large cohort, the use of FM was associated with a small and sustained improvement in HbA 1c , most evident in those with higher baseline HbA 1c levels. In addition, FM users experienced lower rates of severe hypoglycaemic events compared with control individuals using SMBG for self-management of glucose control. Graphical abstract:
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Reductions in acute diabetes complications, such as diabetic ketoacidosis (DKA), episodes of severe hypoglycemia or diabetes-related coma, and hospitalizations for hypoglycemia and hyperglycemia, have been observed in adults with type 1 or type 2 diabetes (43,78,80)”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [78]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“and hypoglycemia (41,43,75,78,79).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [78]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The central role of the propensity score in observational studies for causal effects
ROSENBAUM, P. R., & RUBIN, D. B. (1983) · Biometrika · doi:10.1093/biomet/70.1.41 · Cited by 31,241
Austin, P. C., & Stuart, E. A. (2015) · Statistics in Medicine · doi:10.1002/sim.6607 · Cited by 4,495
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Reducing Bias in Observational Studies Using Subclassification on the Propensity Score
Rosenbaum, P. R., & Rubin, D. B. (1984) · Journal of the American Statistical Association · doi:10.1080/01621459.1984.10478078 · Cited by 3,082 · cited 1×
“Themain analysis was adjusted for confounding using inverse probability of treatment weighting (IPTW) based on propensity scores [13, 14], defined as the probability of being exposed to FM given the observed confounders.”
MethodMcCaffrey, D. F., Ridgeway, G., & Morral, A. R. (2004) · Psychological Methods · doi:10.1037/1082-989x.9.4.403 · Cited by 1,317
Generalized additive models for medical research
Hastie, T., & Tibshirani, R. (1995) · Statistical Methods in Medical Research · doi:10.1177/096228029500400302 · Cited by 1,266
Glycemic Control and Excess Mortality in Type 1 Diabetes
Lind, M., Svensson, A.-M., Kosiborod, M., Gudbjörnsdottir, S., Pivodic, A., Wedel, H., Dahlqvist, S., Clements, M., & Rosengren, A. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1408214 · Cited by 964
Self-citationBolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Self-citationLind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Self-citationthe SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Self-citation
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
“Reductions in acute diabetes complications, such as diabetic ketoacidosis (DKA) and episodes of severe hypoglycemia, have been seen (35,70).”
Background7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
7. Diabetes Technology: Standards of Care in Diabetes—2026
Bajaj, M. S., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Early, K. B., ChallaSivaKanaka, S., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc26-s007 · Cited by 279
Metadata
- Authors
- Nathanson, D., Svensson, A.-M., Miftaraj, M., Franzén, S., Bolinder, J., & Eeg-Olofsson, K.
- Affiliations
- Karolinska University Hospital (SE)
- Centre of Registers Vastra Gotaland (SE)
- Corresponding author
- Bolinder, Jan
- ORCID
- Venue
- Diabetologia
- Published
- 2021-03-27
- Volume
- 64
- Issue
- 7
- Pages
- 1595-1603
- ISSN
- 0012-186X (ISSN-L)
- 1432-0428
- PMC
- PMC8187189
- OpenAlex
- W3146911802
- Cited by
- 61
- References
- 30
- Citations by year
- 2026: 8 · 2025: 7 · 2024: 14 · 2023: 13 · 2022: 13 · 2021: 6
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Diabetologia (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- the Swedish state under the agreement between the Swedish government and the county councils, the ALF agreement (ALFGBG-698991)
- Swedish Diabetes Association and the Strategic Research Program on Diabetes at Karolinska Institutet
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- flash glucose monitoring, type 1 diabetes, glycemic control, HbA1c, severe hypoglycemia, self-monitoring of blood glucose, continuous glucose monitoring, diabetes management, adults with type 1 diabetes, propensity score matching, inverse probability of treatment weighting
- MeSH terms
- Glycemic Control, Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Injections, Insulin, Insulin Infusion Systems, Longitudinal Studies, Male, Middle Aged, Retrospective Studies, Sweden, Blood Glucose Self-Monitoring, Case-Control Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of flash glucose monitoring in adults with type 1 diabetes: a nationwide, longitudinal observational study of 14,372 flash users compared with 7691 glucose sensor naive controls. https://app.cochat.ai/papers/10.1007/s00125-021-05437-z
- The paper
- Nathanson, D., Svensson, A.-M., Miftaraj, M., Franzén, S., Bolinder, J., & Eeg-Olofsson, K. (2021). Effect of flash glucose monitoring in adults with type 1 diabetes: a nationwide, longitudinal observational study of 14,372 flash users compared with 7691 glucose sensor naive controls. Diabetologia. https://doi.org/10.1007/s00125-021-05437-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.