CoChat
Cited by 231

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Diagnosis of ventilator-associated pneumonia in critically ill adult patients—a systematic review and meta-analysis

Open access
Fernando, Shannon M., Tran, Alexandre, Cheng, Wei, Klompas, Michael, Kyeremanteng, Kwadwo, Mehta, Sangeeta, English, Shane W., Muscedere, John, Cook, Deborah J., Torres, Antoni, Ranzani, Otavio T., Fox-Robichaud, Alison E., Alhazzani, Waleed, Munshi, Laveena, Guyatt, Gordon H., Rochwerg, Bram · 2020 · Intensive Care Medicine

Abstract

The accuracy of the signs and tests that clinicians use to diagnose ventilator-associated pneumonia (VAP) and initiate antibiotic treatment has not been well characterized. We sought to characterize and compare the accuracy of physical examination, chest radiography, endotracheal aspirate (ETA), bronchoscopic sampling cultures (protected specimen brush [PSB] and bronchoalveolar lavage [BAL]), and CPIS > 6 to diagnose VAP. We searched six databases from inception through September 2019 and selected English-language studies investigating accuracy of any of the above tests for VAP diagnosis. Reference standard was histopathological analysis. Two reviewers independently extracted data and assessed study quality. We included 25 studies (1639 patients). The pooled sensitivity and specificity of physical examination findings for VAP were poor: fever (66.4% [95% confidence interval [CI]: 40.7–85.0], 53.9% [95% CI 34.5–72.2]) and purulent secretions (77.0% [95% CI 64.7–85.9], 39.0% [95% CI 25.8–54.0]). Any infiltrate on chest radiography had a sensitivity of 88.9% (95% CI 73.9–95.8) and specificity of 26.1% (95% CI 15.1–41.4). ETA had a sensitivity of 75.7% (95% CI 51.5–90.1) and specificity of 67.9% (95% CI 40.5–86.8). Among bronchoscopic sampling methods, PSB had a sensitivity of 61.4% [95% CI 43.7–76.5] and specificity of 76.5% [95% CI 64.2–85.6]; while BAL had a sensitivity of 71.1% [95% CI 49.9–85.9] and specificity of 79.6% [95% CI 66.2–85.9]. CPIS > 6 had a sensitivity of 73.8% (95% CI 50.6–88.5) and specificity of 66.4% (95% CI 43.9–83.3). Classic clinical indicators had poor accuracy for diagnosis of VAP. Reliance upon these indicators in isolation may result in misdiagnosis and potentially unnecessary antimicrobial use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00134-020-06036-z

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 231

Metadata

Authors
Fernando, S. M., Tran, A., Cheng, W., Klompas, M., Kyeremanteng, K., Mehta, S., English, S. W., Muscedere, J., Cook, D. J., Torres, A., Ranzani, O. T., Fox-Robichaud, A. E., Alhazzani, W., Munshi, L., Guyatt, G. H., & Rochwerg, B.
Venue
Intensive Care Medicine
Published
2020-04-18
Volume
46
Issue
6
Pages
1170-1179
ISSN
  • 0342-4642 (ISSN-L)
  • 1432-1238
OpenAlex
W3016513391
Cited by
231
References
8
FWCI
5.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of ventilator-associated pneumonia in critically ill adult patients—a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1007/s00134-020-06036-z
The paper
Fernando, S. M., Tran, A., Cheng, W., Klompas, M., Kyeremanteng, K., Mehta, S., English, S. W., Muscedere, J., Cook, D. J., Torres, A., Ranzani, O. T., Fox-Robichaud, A. E., Alhazzani, W., Munshi, L., Guyatt, G. H., & Rochwerg, B. (2020). Diagnosis of ventilator-associated pneumonia in critically ill adult patients—a systematic review and meta-analysis. Intensive Care Medicine. https://doi.org/10.1007/s00134-020-06036-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.