The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Mitchell, J. P., Schuller, D., Calandrino, F. S., & Schuster, D. P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.5.990 · Cited by 587
Neumann, P. (1999) · Intensive Care Medicine · doi:10.1007/s001340050819 · Cited by 285
Sakka, S. G., Bredle, D. L., Reinhart, K., & Meier‐Hellmann, A. (1999) · Journal of Critical Care · doi:10.1016/s0883-9441(99)90018-7 · Cited by 210
Self-citationGödje, O. L. (1998) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(98)00063-3 · Cited by 206
A Prospective Study of Lung Water Measurements during Patient Management in an Intensive Care Unit
Eisenberg, P. R., Hansbrough, J. R., Anderson, D., & Schuster, D. P. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.3.662 · Cited by 197
Halperin, B. D., Feeley, T. W., Mihm, F. G., et al. (1985) · CHEST Journal · doi:10.1378/chest.88.5.649 · Cited by 144
Thermal Dye Measurements of Extravascular Lung Water in Critically III Patients
Sibbald, W. J., Short, A. K., Warshawski, F., Cunningham, D. G., & Cheung, H. (1985) · CHEST Journal · doi:10.1378/chest.87.5.585 · Cited by 105
Monitoring of right ventricular function using a conventional slow response thermistor catheter
Lichtwarck‐Aschoff, M., Leucht, S., Kisch, H., Zimmermann, G., Blümel, G., & Pfeiffer, U. J. (1994) · Intensive Care Medicine · doi:10.1007/bf01720907 · Cited by 19
Self-citation
Cited by
The Berlin definition of ARDS: an expanded rationale, justification, and supplementary material
Ferguson, N. D., Fan, E., Camporota, L., Antonelli, M., Anzueto, A., Beale, R., Brochard, L., Brower, R., Esteban, A., Gattinoni, L., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2682-1 · Cited by 1,443
Self-citationGlobal End-Diastolic Volume as an Indicator of Cardiac Preload in Patients With Septic Shock *
Michard, F., Alaya, S., Zarka, V., Bahloul, M., Richard, C., & Teboul, J.-L. (2003) · Chest · doi:10.1378/chest.124.5.1900 · Cited by 352
Transpulmonary thermodilution: advantages and limits
Monnet, X., & Teboul, J.-L. (2017) · Critical Care · doi:10.1186/s13054-017-1739-5 · Cited by 285
Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives
Reuter, D. A., Huang, C., Edrich, T., Shernan, S. K., & Eltzschig, H. K. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181cc885a · Cited by 284
Cordemans, C., De laet, I., Van Regenmortel, N., Schoonheydt, K., Dits, H., Huber, W., & Malbrain, M. L. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-s1-s1 · Cited by 271
Metadata
- Authors
- Sakka, S. G., Rühl, C. C., Pfeiffer, U. J., Beale, R., McLuckie, A., Reinhart, K., & Meier-Hellmann, A.
- Venue
- Intensive Care Medicine
- Published
- 2000-03-09
- Volume
- 26
- Issue
- 2
- Pages
- 180-187
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- OpenAlex
- W2048249523
- Cited by
- 920
- References
- 11
- FWCI
- 99.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.