The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Accurate alignment and high function after kinematically aligned TKA performed with generic instruments
Abstract
Purpose: Performing kinematically aligned total knee arthroplasty (TKA) with generic instruments is less costly than patient‐specific instrumentation; however, the alignment and function with this new technique are unknown. Methods: One hundred and one consecutive patients (101 knees) treated with kinematically aligned TKA, implanted with use of generic instruments, were prospectively followed. The medial collateral ligament was not released. The lateral collateral ligament was released in the 17 % of patients with a fixed valgus deformity. Six measures of alignment were categorized from a scanogram of the extremity, an axial scan of the knee, and an intraoperative measurement. Both the Oxford Knee and WOMAC™ scores were assessed as function. High function was a mean Oxford Knee score >41. Results: The frequency that patients were categorized as in‐range was 93 % for the mechanical alignment of the limb (0° ± 3°), 94 % for the joint line (−3° ± 3°), 57 % for the anatomic axis of the knee (−2.5° ± −7.4° valgus), 4 % for the varus–valgus rotation of the tibial component (≤0° valgus), 98 % for the rotation of the tibial component with respect to the femoral component (0° ± 10°), and 94 % for the intraoperative change in the anterior–posterior distance of the tibia with respect to the femur at 90° of flexion (0 ± 2 mm). The mean OKS score was 42, and WOMAC™ score was 89. For each alignment, the function was the same for patients categorized as an outlier or in‐range. Conclusions: The authors prefer the use of generic instruments to perform kinematically aligned TKA in place of mechanically aligned TKA because five of six alignments were accurate and because high function was restored regardless of whether patients had an alignment categorized as an outlier or in‐range. Level of evidence: IV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?
Bourne, R. B., Chesworth, B. M., Davis, A. M., Mahomed, N. N., & Charron, K. D. J. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-1119-9 · Cited by 2,569
Bellemans, J., Colyn, W., Vandenneucker, H., & Victor, J. (2012) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1936-5 · Cited by 1,085
Baker, P. N., van der Meulen, J. H., Lewsey, J., & Gregg, P. J. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b7.19091 · Cited by 975
Kapandji, I. A. (1974) · Churchill Livingstone eBooks · Cited by 881
Parratte, S., Pagnano, M. W., Trousdale, R. T., & Berry, D. J. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01398 · Cited by 808
The Effect of Alignment and BMI on Failure of Total Knee Replacement
Ritter, M. A., Davis, K. E., Meding, J. B., Pierson, J. L., Berend, M. E., & Malinzak, R. A. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00772 · Cited by 669
The Axes of Rotation of the Knee
HOLLISTER, A. M., JATANA, S., SINGH, A. K., SULLIVAN, W. W., & LUPICHUK, A. G. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199305000-00033 · Cited by 502
Howell, S. M., Howell, S. J., Kuznik, K. T., Cohen, J., & Hull, M. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2613-z · Cited by 495
Self-citationVanlommel, L., Vanlommel, J., Claes, S., & Bellemans, J. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-013-2481-4 · Cited by 322
Flexion Instability After Primary Posterior Cruciate Retaining Total Knee Arthroplasty
Pagnano, M. W., Hanssen, A. D., Lewallen, D. G., & Stuart, M. J. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199811000-00008 · Cited by 310
Cited by
MacDessi, S. J., Griffiths-Jones, W., Harris, I. A., Bellemans, J., & Chen, D. B. (2021) · The Bone & Joint Journal · doi:10.1302/0301-620x.103b2.bjj-2020-1050.r1 · Cited by 738
Dossett, H. G., Estrada, N. A., Swartz, G. J., LeFevre, G. W., & Kwasman, B. G. (2014) · The Bone & Joint Journal · doi:10.1302/0301-620x.96b7.32812 · Cited by 431
Patient dissatisfaction following total knee replacement: a growing concern?
Nam, D., Nunley, R. M., & Barrack, R. L. (2014) · The Bone & Joint Journal · doi:10.1302/0301-620x.96b11.34152 · Cited by 364
Young, S. W., Walker, M. L., Bayan, A., Briant-Evans, T., Pavlou, P., & Farrington, B. (2017) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-016-4844-x · Cited by 256
Calliess, T., Bauer, K., Stukenborg-Colsman, C., Windhagen, H., Budde, S., & Ettinger, M. (2017) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4136-8 · Cited by 245
Metadata
- Authors
- Howell, S. M., Papadopoulos, S., Kuznik, K. T., & Hull, M. L.
- Venue
- Knee Surgery, Sports Traumatology, Arthroscopy
- Publisher
- Wiley
- Published
- 2013-08-15
- Volume
- 21
- Issue
- 10
- Pages
- 2271-2280
- ISSN
- 0942-2056 (ISSN-L)
- 1433-7347
- OpenAlex
- W2170195819
- Cited by
- 366
- References
- 22
- FWCI
- 15.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate alignment and high function after kinematically aligned TKA performed with generic instruments. https://app.cochat.ai/papers/10.1007/s00167-013-2621-x
- The paper
- Howell, S. M., Papadopoulos, S., Kuznik, K. T., & Hull, M. L. (2013). Accurate alignment and high function after kinematically aligned TKA performed with generic instruments. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-013-2621-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.