Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Opportunistic screening for osteoporosis by routine CT in Southern Europe

Open access
Alacreu, Elena, Moratal, David, Arana, Estanislao · 2017 · Osteoporosis International

Abstract

SummaryFeasibility evaluation of early detection of osteoporosis in oncologic patients by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed for other clinical indications, by using dual-energy X-ray absorptiometry (DXA) as reference. Abdominal CT images can identify patients with osteoporosis BMD without additional radiation exposure or cost.IntroductionThe purpose of the study is to evaluate the feasibility of early detection of osteoporosis by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed in oncologic patients, comparing calibrated and uncalibrated measurements by using dual-energy X-ray absorptiometry (DXA) as reference. We also performed an external validation of a threshold of 160 Hounsfield units (HU), proposed as highly sensitive.MethodsCohort comprised CT-DXA pairs within a 6-month period performed for any indication on 326 consecutive adults, aged 62.4 ± 12.38 years (mean ± standard deviation). CT attenuation of trabecular bone in HU was measured at the axial cross sections of L1, L2, L3, and L4 vertebrae. Vertebral compression fractures were assessed by sagittal reconstruction view. Diagnostic performance measures and the area under the receiver operator characteristic curve (AUC) for diagnosing osteoporosis were calculated.ResultsBMD values were statistical significantly lower at any vertebral level from L1 to L4 for patients with osteoporosis defined by DXA (p < 0.001). Calibrated and uncalibrated BMD values were significantly correlated (R2 = 0.833, p < 0.01). An uncalibrated L1 CT attenuation threshold of 160 HU was more than 90 % sensitive, and a threshold of 73 HU was more than 90 % specific for distinguishing osteoporosis BMD. Fifty-nine percent of patients with vertebral compression fracture had non-osteoporotic DXA T-scores.ConclusionsAbdominal CT images obtained for other reasons can identify patients with osteoporosis BMD without additional radiation exposure or cost. Uncalibrated values at L1 can detect more osteoporosis patients with spinal compression fractures than DXA in oncologic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00198-016-3804-3

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 159

Metadata

Authors
Alacreu, E., Moratal, D., & Arana, E.
Venue
Osteoporosis International
Published
2017-01-20
Volume
28
Issue
3
Pages
983-990
ISSN
  • 0937-941X (ISSN-L)
  • 1433-2965
OpenAlex
W2571578109
Cited by
159
References
3
FWCI
11.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Opportunistic screening for osteoporosis by routine CT in Southern Europe. https://app.cochat.ai/papers/10.1007/s00198-016-3804-3
The paper
Alacreu, E., Moratal, D., & Arana, E. (2017). Opportunistic screening for osteoporosis by routine CT in Southern Europe. Osteoporosis International. https://doi.org/10.1007/s00198-016-3804-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.