CoChat

Magnetic ionic liquids as versatile extraction phases for the rapid determination of estrogens in human urine by dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection

Merib, Josias, Spudeit, Daniel A., Corazza, Gabriela, Carasek, Eduardo, Anderson, Jared L. · 2018 · Analytical and Bioanalytical Chemistry

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

In this study, a rapid and straightforward approach based on magnetic ionic liquids (MIL) as extraction phases and dispersive liquid-liquid microextraction (DLLME) was developed to analyze the hormones estriol, 17-β-estradiol, 17-α-ethynylestradiol, and estrone in human urine samples. This is the first report of an application of manganese-based MILs compatible with HPLC to extract compounds of biological interest from urine samples. The hydrophobic MILs trihexyltetradecylphosphonium tetrachloromanganate (II) ([P 6,6,6,14 + ] 2 [MnCl 4 2- ]) and aliquat tetrachloromanganate (II) ([Aliquat + ] 2 [MnCl 4 2- ]) were employed and the optimized extraction conditions were comprised of 5 mg of MIL ([P 6,6,6,14 + ] 2 [MnCl 4 2- ]), 5 μL of methanol (MeOH) as disperser solvent, and an extraction time of 90 s at sample pH 6. The analytical parameters of merit were determined under optimized conditions and very satisfactory results were achieved, with LODs of 2 ng mL -1 for all analytes, determination coefficients (R 2 ) ranging from 0.9949 for 17-β-estradiol to 0.9998 for estrone. In addition, good results of method precision were achieved with the intraday (n = 3) varying from 4.7% for 17-β-estradiol to 19.5% for estriol (both at 5 ng mL -1 ) and interday precision (evaluated at 100 ng mL -1 ) ranging from 11.4% for estrone to 17.7% for 17-α-ethynylestradiol and analyte relative recovery evaluated in three real samples ranged from 67.5 to 115.6%. The proposed DLLME/MIL-based approach…

Overview

Integrity signals

Registry

Crossref · 10.1007/s00216-017-0823-7

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 38 references

Cited by

See all 85

Metadata

Authors
Merib, J., Spudeit, D. A., Corazza, G., Carasek, E., & Anderson, J. L.
Affiliations
  • Universidade Federal de Santa Catarina (BR)
  • Iowa State University (US)
Corresponding author
Carasek, Eduardo
Venue
Analytical and Bioanalytical Chemistry
Published
2018-01-08
Volume
410
Issue
19
Pages
4689-4699
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W2782773926
Cited by
79
References
38
Citations by year
2025: 9 · 2024: 10 · 2023: 3 · 2022: 11 · 2021: 10 · 2020: 13 · 2019: 15 · 2018: 8
FWCI
7.17
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical and Bioanalytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Fundação de Amparo à Pesquisa e Inovação do Estado de Santa Catarina (455/2016)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (303892/2014-5)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
Keywords
magnetic ionic liquids, dispersive liquid-liquid microextraction, estrogen, human urine, estradiol, estrone, estriol, ethinyl estradiol, HPLC-DAD, hormone analysis
MeSH terms
Adult, Chromatography, High Pressure Liquid, Estradiol, Estrogens, Estrone, Ethinyl Estradiol, Female, Humans, Magnetics, Male, Ionic Liquids, Limit of Detection, Magnets, Liquid Phase Microextraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic ionic liquids as versatile extraction phases for the rapid determination of estrogens in human urine by dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection. https://app.cochat.ai/papers/10.1007/s00216-017-0823-7
The paper
Merib, J., Spudeit, D. A., Corazza, G., Carasek, E., & Anderson, J. L. (2018). Magnetic ionic liquids as versatile extraction phases for the rapid determination of estrogens in human urine by dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-017-0823-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.