CoChat

FluoroMatch 2.0—making automated and comprehensive non-targeted PFAS annotation a reality

Open access
Koelmel, Jeremy P., Stelben, Paul, McDonough, Carrie A., Dukes, David A., Aristizabal-Henao, Juan J., Nason, Sara L., Li, Yang, Sternberg, Sandi, Lin, Elizabeth, Beckmann, Manfred, Williams, Antony J., Draper, John, Finch, Jasen P., Munk, Jens K., Deigl, Chris, Rennie, Emma E, Bowden, John A., Godri Pollitt, Krystal J. · 2022 · Analytical and Bioanalytical Chemistry
Cited by 121

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Because of the pervasiveness, persistence, and toxicity of per- and polyfluoroalkyl substances (PFAS), there is growing concern over PFAS contamination, exposures, and health effects. The diversity of potential PFAS is astounding, with nearly 10,000 PFAS catalogued in databases to date (and growing). The ability to detect the thousands of known PFAS, and discover previously uncatalogued PFAS, is necessary to understand the scope of PFAS contamination and to identify appropriate remediation and regulatory solutions. Current non-targeted methods for PFAS analysis require manual curation and are time-consuming, prone to error, and not comprehensive. FluoroMatch Flow 2.0 is the first software to cover all steps of data processing for PFAS discovery in liquid chromatography–high-resolution tandem mass spectrometry samples. These steps include feature detection, feature blank filtering, exact mass matching to catalogued PFAS, mass defect filtering, homologous series detection, retention time pattern analysis, class-based MS/MS screening, fragment screening, and predicted MS/MS from SMILES structures. In addition, a comprehensive confidence level criterion is implemented to help users understand annotation certainty and integrate various layers of evidence to reduce overreporting. Applying the software to aqueous film forming foam analysis, we discovered over one thousand likely PFAS including previously unreported species. Furthermore, we were able to filter out 96% of features which were likely not PFAS. FluoroMatch Flow 2 increased coverage of likely PFAS by over tenfold compared to the previous release. This software will enable researchers to better characterize PFAS in the environment and in biological systems. Graphical abstract

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00216-021-03392-7

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 121

Metadata

Authors
Koelmel, J. P., Stelben, P., McDonough, C. A., Dukes, D. A., Aristizabal-Henao, J. J., Nason, S. L., Li, Y., Sternberg, S., Lin, E., Beckmann, M., Williams, A. J., Draper, J., Finch, J. P., Munk, J. K., Deigl, C., Rennie, E. E., Bowden, J. A., & Godri Pollitt, K. J.
Venue
Analytical and Bioanalytical Chemistry
Published
2021-05-20
Volume
414
Issue
3
Pages
1201-1215
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W3163142243
Cited by
121
References
21
FWCI
6.12
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: FluoroMatch 2.0—making automated and comprehensive non-targeted PFAS annotation a reality. https://app.cochat.ai/papers/10.1007/s00216-021-03392-7
The paper
Koelmel, J. P., Stelben, P., McDonough, C. A., Dukes, D. A., Aristizabal-Henao, J. J., Nason, S. L., Li, Y., Sternberg, S., Lin, E., Beckmann, M., Williams, A. J., Draper, J., Finch, J. P., Munk, J. K., Deigl, C., Rennie, E. E., Bowden, J. A., & Godri Pollitt, K. J. (2022). FluoroMatch 2.0—making automated and comprehensive non-targeted PFAS annotation a reality. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-021-03392-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.