Biosensors and biochips: advances in biological and medical diagnostics
Open accessAbstract
In the past two decades, the biological and medical fields have seen great advances in the development of biosensors and biochips capable of characterizing and quantifying biomolecules. This review is meant to provide an overview of the various types of biosensors and biochips that have been developed for biological and medical applications, along with significant advances over the last several years in these technologies. It also attempts to describe various classification schemes that can be used for categorizing the different biosensors and provide relevant examples of these classification schemes from recent literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemical and biological sensors
Nylander, C. (1985) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/18/9/003 · Cited by 100
Cited by
An overview of foodborne pathogen detection: In the perspective of biosensors
Velusamy, V., Arshak, K., Korostynska, O., Oliwa, K., & Adley, C. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.12.004 · Cited by 1,185
The Role of Reactive Oxygen Species (ROS) in the Biological Activities of Metallic Nanoparticles
Abdal Dayem, A., Hossain, M., Lee, S., Kim, K., Saha, S., Yang, G.-M., Choi, H., & Cho, S.-G. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18010120 · Cited by 1,141
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Food safety impacts of antimicrobial use and their residues in aquaculture
Okocha, R. C., Olatoye, I. O., & Adedeji, O. B. (2018) · Public Health Reviews · doi:10.1186/s40985-018-0099-2 · Cited by 513
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
Biosensor technology: Technology push versus market pull
Luong, J. H. T., Male, K. B., & Glennon, J. D. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.05.007 · Cited by 454
Nanotechnology and its use in imaging and drug delivery (Review)
Sim, S., & Wong, N. (2021) · Biomedical Reports · doi:10.3892/br.2021.1418 · Cited by 454
Optical fibre nanowires and microwires: a review
Brambilla, G. (2010) · Journal of Optics · doi:10.1088/2040-8978/12/4/043001 · Cited by 370
Critical review and perspective of macromolecularly imprinted polymers
Kryscio, D. R., & Peppas, N. A. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.005 · Cited by 367
Gaudin, V. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.005 · Cited by 325
Antibody production, design and use for biosensor-based applications
Conroy, P. J., Hearty, S., Leonard, P., & O’Kennedy, R. J. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.01.010 · Cited by 314
Review—Nanostructured Materials-Based Nanosensors
Abdel-Karim, R., Reda, Y., & Abdel-Fattah, A. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67aa · Cited by 303
Biosensors - classification, characterization and new trends
Monošík, R., Streďanský, M., & Šturdík, E. (2012) · Acta Chimica Slovaca · doi:10.2478/v10188-012-0017-z · Cited by 269
Fritz, J. (2008) · The Analyst · doi:10.1039/b718174d · Cited by 254
Emotion-on-a-chip (EOC): Evolution of biochip technology to measure human emotion using body fluids
Lee, J.-H., Hwang, Y., Cheon, K.-A., & Jung, H.-I. (2012) · Medical Hypotheses · doi:10.1016/j.mehy.2012.09.002 · Cited by 20
Metadata
- Authors
- Vo-Dinh, T., & Cullum, B.
- Venue
- Fresenius' Journal of Analytical Chemistry
- Published
- 2000-03-30
- Volume
- 366
- Issue
- 6-7
- Pages
- 540-551
- ISSN
- 0937-0633 (ISSN-L)
- 1432-1130
- OpenAlex
- W2054115296
- Cited by
- 509
- References
- 1
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.