Modelling the limit of detection in real-time quantitative PCR
The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.
Abstract
The limit of detection (LOD) is a critical performance characteristic of an assay that requires careful evaluation during method validation. However, formal calculations for the LOD do not take into account atypical data sets that are generated from real-time PCR techniques, which can be non-normally distributed, truncated, and heteroscedastic. Experimental data sets for the quantification of genetically modified (GM) material were produced using real-time PCR, in order to model the LOD. A bootstrapping computer simulation calculated the probabilities of detecting PCR positive test results from these data sets, and computer modelling defined a function from the resulting probability plots. The LOD was modelled as a function of sample replication level and cycle threshold values. The broad applicability of this bootstrapping and data modelling approach should be of general interest to laboratories conducting trace-level detection.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“C q values Ͼ40 are suspect because of the implied low efficiency and generally should not be reported”
From The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments (2009) · cites this paper as [26]
In the citing paper
“however, the use of such arbitrary C q cutoffs is not ideal, because they may be either too low (eliminating valid results) or too high (increasing false-positive results) (26 )”
From The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments (2009) · cites this paper as [26]
Citations
Cites
Nuclear DNA content of some important plant species
Arumuganathan, K., & Earle, E. D. (1991) · Plant Molecular Biology Reporter · doi:10.1007/bf02672069 · Cited by 3,237
PCR technology for screening and quantification of genetically modified organisms (GMOs)
Holst-Jensen, A., Rønning, S. B., Løvseth, A., & Berdal, K. G. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1767-7 · Cited by 371 · cited 1×
“LOQ [32].”
Compendium of chemical terminology : IUPAC recommendations
Mcnaught, A. D., & Wilkinson, A. (1997) · Cited by 353
Berdal, K., & Holst-Jensen, A. (2001) · European Food Research and Technology · doi:10.1007/s002170100403 · Cited by 225 · cited 2×
“A recent publication [ 29 ] proposed to use definitions of the LOD and LOQ associated with both the method (through use of reference materials and relative values in a validation) and the practical LOD/LOQ associated with the actual test sample.”
MethodInfluentialRoutes to improving the reliability of low level DNA analysis using real-time PCR
Ellison, S. L., English, C. A., Burns, M. J., & Keer, J. T. (2006) · BMC Biotechnology · doi:10.1186/1472-6750-6-33 · Cited by 207 · cited 1×
“A recent study used serial dilutions of human genomic DNA and real-time PCR to investigate the effect of DNA preparation on quantification, and different approaches for inclusion of sample values in the production of a calibration curve [36].”
MethodSelf-citationBurns, M. J., Nixon, G. J., Foy, C. A., & Harris, N. (2005) · BMC Biotechnology · doi:10.1186/1472-6750-5-31 · Cited by 179
Self-citationOptimized Real-Time Quantitative PCR Measurement of Male Fetal DNA in Maternal Plasma
Zimmermann, B., El-Sheikhah, A., Nicolaides, K., Holzgreve, W., & Hahn, S. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051235 · Cited by 165 · cited 1×
“19 copies [35].”
Validation of PCR Methods for Quantitation of Genetically Modified Plants in Food
Hübner, P., Waiblinger, H., Pietsch, K., & Brodmann, P. (2001) · Journal of AOAC International · doi:10.1093/jaoac/84.6.1855 · Cited by 141
Kulesh, D. A., Baker, R. O., Loveless, B. M., Norwood, D., Zwiers, S. H., Mucker, E. M., Hartmann, C., Herrera, R., Miller, D., Christensen, D. R., et al. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.2.601-609.2004 · Cited by 130 · cited 1×
“Further research in this area developed a TaqMan real-time quantitative PCR assay for detection of both the smallpox and pan-othopx virus DNA [34].”
MethodEvent specific real-time quantitative PCR for genetically modified Bt11 maize (Zea mays)
Rønning, S. B., Vaïtilingom, M., Berdal, K. G., & Holst‐Jensen, A. (2003) · European Food Research and Technology · doi:10.1007/s00217-002-0653-4 · Cited by 115 · cited 1×
“Similarly, the LOD associated with the event-specific detection of Roundup Ready soybean using TaqMan chemistry on a LightCycler, was reported as being at 3.4 copies [29], and for the event specific detection of Bt11 maize using realtime PCR on the LightCycler, an LOD of 10 copies was specified [ 30 ], although it was…”
MethodInfluential
Research works printed but not linked: 7
- Prichard E, co-ordinating author (2001) Analytical measurement terminology. Published for LGC by the Royal Society of Chemistry, Thomas Graham House, Science Park, Cambridge, ISBN 0-85404-443-4
- Draft International Harmonisation of Pharmacopoeias (1993) Text in validation of analytical procedure. Pharmeuropa 5(4):341
- Directive 2001/18/EC, Official Journal L 106 (17/04/2001) p1–39. The European Parliament and the Council of the European Union, Brussels
- European Commission Regulation (EC) No. 1830/1997 Official Journal Eur Communities L 268 (18.10.2003). The European Parliament and the Council of the European Union, Brussels
- European Commission Regulation (EC) No. 1829/2003 Official Journal Eur Communities L 268/1 (18.10.2003). The European Parliament and the Council of the European Union, Brussels
- Foy C, Parkes H (2001) Emerging homogeneous DNA-based technologies in the clinical laboratory. Clin Chem 47:990–1000 · DOI
- Sharp J (2002) Development of immunomagnetic capture (IMC) based techniques for the detection of Salmonella on poultry carcasses. MSc thesis, Virginia Polytechnic Institute and State University, Blacksburg
Cited by
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
“Cq values 40 are suspect because of the implied low efficiency and generally should not be reported; however, the use of such arbitrary Cq cutoffs is not ideal, because they may be either too low (eliminating valid results) or too high (increasing false-positive results) ( 26 ).”
BackgroundA Basic Guide to Real Time PCR in Microbial Diagnostics: Definitions, Parameters, and Everything
Kralik, P., & Ricchi, M. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2017.00108 · Cited by 927
“However, it should be noted that LOD definitions described above were reported for chemical methods, and are not perfectly suited for PCR methods (Burns and Valdivia, 2008).”
BackgroundReporting the limits of detection and quantification for environmental DNA assays
Klymus, K. E., Merkes, C. M., Allison, M. J., Goldberg, C. S., Helbing, C. C., Hunter, M. E., Jackson, C. A., Lance, R. F., Mangan, A. M., Monroe, E. M., et al. (2020) · Environmental DNA · doi:10.1002/edn3.29 · Cited by 582
“…of target analyte that can be detected with a defined level of con‐ fidence, with a 95% detection rate as the standard confidence level (Burd, 2010; Burns & Valdivia, 2007; Bustin et al., 2009; CLSI, 2012; Forootan et al., 2017; Furlan, Gleeson, Hardy, & Duncan, 2016; Wolk & Marlowe, 2011).”
BackgroundForootan, A., Sjöback, R., Björkman, J., Sjögreen, B., Linz, L., & Kubista, M. (2017) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2017.04.001 · Cited by 578
“LoD for qPCR methods can be estimated from analysis of replicate standard curves [10].”
MethodWhy the need for qPCR publication guidelines?—The case for MIQE
Bustin, S. A. (2010) · Methods · doi:10.1016/j.ymeth.2009.12.006 · Cited by 375
A review of Theileria diagnostics and epidemiology
Mans, B. J., Pienaar, R., & Latif, A. A. (2015) · International Journal for Parasitology: Parasites and Wildlife · doi:10.1016/j.ijppaw.2014.12.006 · Cited by 320
“In practice, however, this may range from 3 – > 100 molecules and a cut-off from 37 to 40 cycles (Burns and Valdivia, 2008; Bhoora et al., 2010a).”
BackgroundFasseu, M., Tréton, X., Guichard, C., Pedruzzi, E., Cazals-Hatem, D., Richard, C., Aparicio, T., Daniel, F., Soulé, J.-C., Moreau, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013160 · Cited by 286
“The cycle number above which the CT was considered as a false positive (cycle cut-off point) was set up at 35, as already argued in the literature dealing with limits of detection in Real-Time Quantitative- RT-PCR [74] ( reviewed in [73]).”
Caraguel, C. G. B., Stryhn, H., Gagné, N., Dohoo, I. R., & Hammell, K. L. (2011) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/104063871102300102 · Cited by 240
“Two approaches were suggested to estimate the ASe of qPCR.(7) The first, referred to as ‘‘experimental’’ ASe (ASeexp), determines the last investigated serial dilution where at least 95% of the samples tested positive.”
BackgroundMethodInfluentialBrankatschk, R., Bodenhausen, N., Zeyer, J., & Bürgmann, H. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.07878-11 · Cited by 226
“CT values of replicated standard dilutions can also be helpful in assessing the limit of detection (4, 6).”
BackgroundMcCall, C., Wu, H., Miyani, B., & Xagoraraki, I. (2020) · Water Research · doi:10.1016/j.watres.2020.116160 · Cited by 169
“The limit of detection (LOD) for each virus was determined by the lowest point on the standard curve or by the lowest dilution with a 95% positive detection rate in at least 10 replicates (Burns and Valdivia, 2008).”
BackgroundNelson, M. T., Pope, C. E., Marsh, R. L., Wolter, D. J., Weiss, E. J., Hager, K. R., Vo, A. T., Brittnacher, M. J., Radey, M. C., Hayden, H. S., et al. (2019) · Cell Reports · doi:10.1016/j.celrep.2019.01.091 · Cited by 173
“Based on the following commonly used definition of limit of detection (LOD) for qPCR (Burns and Valdivia, 2007; Bustin et al., 2009), ‘‘the lowest copy number associated with the serial dilution that gave a positive PCR response on 95% of occasions,’’ the LOD of our qPCR assay is approximately 8.”
MethodVrålstad, T., Knutsen, A. K., Tengs, T., & Holst-Jensen, A. (2009) · Veterinary Microbiology · doi:10.1016/j.vetmic.2008.12.022 · Cited by 164
“If used, a Ct cut-off value should be carefully evaluated for individual assays and RT-PCR thermal cyclers in order to minimize the number of false negatives and positives (Burns and Valdivia, 2008).”
MethodAhmed, W., Harwood, V. J., Gyawali, P., Sidhu, J. P. S., & Toze, S. (2015) · Applied and Environmental Microbiology · doi:10.1128/aem.03851-14 · Cited by 150
“The lower limit of quantification (LLOQ) provides a CT value where a quantitative number can be determined (40).”
BackgroundCRISPR Systems for COVID-19 Diagnosis
Rahimi, H., Salehiabar, M., Barsbay, M., Ghaffarlou, M., Kavetskyy, T. S., Sharafi, A., Davaran, S., Chauhan, S. C., Danafar, H., Kaboli, S., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.0c02312 · Cited by 147
A critical review of methods for detecting human noroviruses and predicting their infectivity
Knight, A. I., Li, D., Uyttendaele, M., & Jaykus, L. (2012) · Critical Reviews in Microbiology · doi:10.3109/1040841x.2012.709820 · Cited by 158
Use and Misuse of Cq in qPCR Data Analysis and Reporting
Ruiz‐Villalba, A., Ruijter, J. M., & van den Hoff, M. J. B. (2021) · Life · doi:10.3390/life11060496 · Cited by 162
“Assuming that the PCR will amplify a single copy when it is present, the Poisson sampling variation will limit the LOD to three copies in the reaction with a false negative rate of 3% [2,44].”
Hecker, M., Thamilarasan, M., Koczan, D., Schröder, I., Flechtner, K., Freiesleben, S., Füllen, G., Thiesen, H.-J., & Zettl, U. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140816087 · Cited by 125
“In case of the TaqMan single-tube real-time PCR miRNA assays, we set the detection limit at Ct = 38 [71], calculated the mean Ct value of each triplicate, converted the raw Ct values to the linear scale using the equation 2 −Ct , normalized the results to the expression values of the housekeeping miRNA hsa-miR-191-5p…”
MethodBasic principles for developing real-time PCR methods used in food analysis: A review
Kang, T. S. (2019) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2019.07.037 · Cited by 117
Pourmadadi, M., Dinani, H. S., Tabar, F. S., Khassi, K., Janfaza, S., Tasnim, N., & Hoorfar, M. (2022) · Biosensors · doi:10.3390/bios12050269 · Cited by 123
“of detection (LOD) is very important in routine diagnosis [257].”
BackgroundAgersnap, S., Larsen, W. B., Knudsen, S. W., Strand, D., Thomsen, P. F., Hesselsøe, M., Mortensen, P. B., Vrålstad, T., & Møller, P. R. (2017) · PLoS ONE · doi:10.1371/journal.pone.0179261 · Cited by 131
“In contrast to the eDNA studies, there are several strict statistically based standards for calculating LOD and LOQ for analytical qPCR used in food and disease diagnostics [60, 19, 61], with defined rules for acceptance levels of variance for quantification.”
MethodResultComparison among the Quantification of Bacterial Pathogens by qPCR, dPCR, and Cultural Methods
Ricchi, M., Bertasio, C., Boniotti, M. B., Vicari, N., Russo, S., Tilola, M., Bellotti, M. A., & Bertasi, B. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2017.01174 · Cited by 88
Scaravelli, E., Brohée, M., Marchelli, R., & van Hengel, A. J. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2849-y · Cited by 86
Grøndahl-Rosado, R. C., Yarovitsyna, E., Trettenes, E., Myrmel, M., & Robertson, L. J. (2014) · Food and Environmental Virology · doi:10.1007/s12560-014-9161-5 · Cited by 74
“The level of detection (LOD) was calculated as previously suggested (Burns & Valdivia 2007; Bustin et al. 2009) by determining the lowest concentration at which 95 % of the positive samples are detected.”
MethodUhlig, S., Frost, K., Colson, B., Simon, K., Mäde, D., Reiting, R., Gowik, P., & Grohmann, L. (2015) · Accreditation and Quality Assurance · doi:10.1007/s00769-015-1112-9 · Cited by 69
“It reflects the asymmetric shape of typical POD curves better than the logistic model proposed by Burns and Valdivia [13].”
MethodBoothroyd, M., Mandrak, N. E., Fox, M., & Wilson, C. C. (2016) · Aquatic Conservation Marine and Freshwater Ecosystems · doi:10.1002/aqc.2617 · Cited by 77
Stokdyk, J. P., Firnstahl, A. D., Spencer, S. K., Burch, T. R., & Borchardt, M. A. (2016) · Water Research · doi:10.1016/j.watres.2016.03.026 · Cited by 65
Recommendations following a multi-laboratory comparison of microbial source tracking methods
Stewart, J. R., Boehm, A. B. B., Dubinsky, E. A., Fong, T.-T., Goodwin, K. D., Griffith, J. F., Noble, R. T., Shanks, O. C., VIJAYAVEL, K., & Weisberg, S. B. (2013) · Water Research · doi:10.1016/j.watres.2013.04.063 · Cited by 64
Reichley, S. R., Ware, C. C., Greenway, T. E., Wise, D. J., & Griffin, M. J. (2015) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638714566672 · Cited by 64
Guthrie, A. J., MacLachlan, N. J., Joone, C., Lourens, C. W., Weyer, C. T., Quan, M., Monyai, M. S., & Gardner, I. A. (2013) · Journal of Virological Methods · doi:10.1016/j.jviromet.2012.12.014 · Cited by 61
Leslie, D. C., Li, J., Strachan, B. C., Begley, M. R., Finkler, D., Bazydlo, L. A. L., Barker, N. S., Haverstick, D. M., Utz, M., & Landers, J. P. (2012) · Journal of the American Chemical Society · doi:10.1021/ja300839n · Cited by 58
McCall, C., Wu, H., O’Brien, E. S., & Xagoraraki, I. (2021) · Journal of Applied Microbiology · doi:10.1111/jam.15027 · Cited by 55
“The LOD was defined as the lowest copy number belonging to the serial dilution that yielded a positive PCR response in 95% of occurrences (Burns and Valdivia 2008).”
BackgroundSchroeder, M. E., Bounpheng, M. A., Rodgers, S., Baker, R. J., Black, W., Naikare, H., Velayudhan, B., Sneed, L., Szonyi, B., & Clavijo, A. (2012) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638712456976 · Cited by 54
“Probit analysis was performed using statistical software to assess the limit of detection of each assay.(8,22) The PCR efficiency was calculated using the following formula: E = 10(–1/slope) − 1 × 100.”
MethodMolecular and serological in-herd prevalence of Anaplasma marginale infection in Texas cattle
Hairgrove, T. B., Schroeder, M. E., Budke, C. M., RODGERS, S. J., Chung, C. J., Ueti, M. W., & Bounpheng, M. A. (2015) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2015.02.006 · Cited by 51
Keller, L., Patel, C., Welsche, S., Schindler, T., Hürlimann, E., & Keiser, J. (2020) · Parasites & Vectors · doi:10.1186/s13071-020-04401-x · Cited by 51
Winter, S. C., Stephenson, S., Subramaniam, S. K., Paleri, V., Ha, K. O., Marnane, C. N., Krishnan, S., & Rees, G. L. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-424 · Cited by 45
“It is well recognised that CTCs are not always detected even when advanced metastatic disease is present and this is presumed to be the result of either sampling errors [42], intermittent tumor cell shedding [43], effective immune surveillance [44] or stochastic effects at the lower limits of sensitivity of the assay…”
BackgroundDescription of the first recorded major occurrence of equine viral arteritis in France
Pronost, S., Pitel, P., Miszczak, F., Legrand, L., Marcillaud‐Pitel, C., HAMON, M., Tapprest, J., Balasuriya, U. B. R., Freymuth, F., & Fortier, G. D. (2010) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.2010.00109.x · Cited by 45
“Furthermore, defining an arbitrary cut-off is not ideal (Burns and Valdivia 2008).”
BackgroundGuidi, V., Lehner, A., Lüthy, P., & Tonolla, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055658 · Cited by 42
“The detection limit was defined as the lowest number of spores in a sample required to obtain a positive result in 95% of samples analyzed [35].”
BackgroundLi, D., Butot, S., Zuber, S., & Uyttendaele, M. (2018) · Food Control · doi:10.1016/j.foodcont.2018.02.024 · Cited by 42
A CRISPR-Cas12a-based specific enhancer for more sensitive detection of SARS-CoV-2 infection
Huang, W., Yu, L., Wen, D., Wei, D., Sun, Y., Zhao, H., Ye, Y., Chen, W., Zhu, Y., Wang, L., et al. (2020) · EBioMedicine · doi:10.1016/j.ebiom.2020.103036 · Cited by 42
“Consistent with the theoretical analysis [23] and the rigorous experimentation [21], along with the decrease of the RNA templates to less than 3 copies/Rx, the rRT-PCR Ct values in some replicas, primarily that corresponding to the N gene, passed 38 (the cut-off for positive as recommended by the rRT-PCR kit suppliers…”
Tutorial: Guidelines for Single-Cell RT-qPCR
Žucha, D., Kubista, M., & Valihrach, L. (2021) · Cells · doi:10.3390/cells10102607 · Cited by 43
“The theory of reporting minimal copy numbers sets the LoD to three molecules per reaction, but in reality, this number increases up to ten molecules [28,67,86,87].”
BackgroundAnalytical and clinical evaluation of biomarkers assays: When are biomarkers ready for prime time?
Pennello, G. A. (2013) · Clinical Trials · doi:10.1177/1740774513497541 · Cited by 41
“Melanoma patients who are V600E mutation positive by the test are eligible for treatment with vemurafenib [36].”
BackgroundA duplex real-time RT-PCR for the detection of bluetongue virus in bovine semen
Vanbinst, T., Vandenbussche, F., Dernelle, E., & Clercq, K. D. (2010) · Journal of Virological Methods · doi:10.1016/j.jviromet.2010.07.019 · Cited by 41
Baerwald, M. R., Schreier, B. M., Schumer, G., & May, B. P. (2012) · Transactions of the American Fisheries Society · doi:10.1080/00028487.2012.717521 · Cited by 40
Isaksen, T. E., Karlsbakk, E., Repstad, O., & Nylund, A. (2012) · Parasitology International · doi:10.1016/j.parint.2012.07.006 · Cited by 47
“Hence CT values above 38 may represent false positives and increase the possibility for Type I error (true negative considered as positive) if such test results are not rejected [29].”
BackgroundTransgene Detection by Digital Droplet PCR
Moser, D., Braga, L., Raso, A., Zacchigna, S., Giacca, M., & Simon, P. D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111781 · Cited by 40
“[25] using standard calibrators in a background of 500 ng hgDNA.”
MethodRiedel, T. E., Thulsiraj, V., Zimmer-Faust, A. G., Dagit, R., Krug, J., Hanley, K. T., Adamek, K., Ebentier, D. L., Torres, R., Cobian, U., et al. (2014) · Water Research · doi:10.1016/j.watres.2014.12.037 · Cited by 36
“Assay LODs were determined with logistic modeling of the pooledmaster standard curve data at a detection frequency of 95% (Burns and Valdivia, 2007).”
MethodWu, X., Huang, X. H., Zhu, Y., Li, J., & Hoffmann, M. R. (2020) · Separation and Purification Technology · doi:10.1016/j.seppur.2020.116540 · Cited by 35
Cao, N., Tang, Z., Zhang, X., Li, W., Li, B., Tian, Y., & Xu, D. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2021.792322 · Cited by 35
“When the plasmids are diluted below 5 × 101 copies/assay, apparently and randomly distributed Ct values in the range of 36–38 are observed in the triplex assay (38, 39).”
BackgroundMethodHolmes, A. E., Baerwald, M. R., Rodzen, J. A., Schreier, B. M., Mahardja, B., & Finger, A. J. (2024) · PeerJ · doi:10.7717/peerj.16453 · Cited by 31
“There is no standard censored data method for eDNA data analysis. qPCR data does not conform to the expectations of other types of environmental data ( Burns & Valdivia, 2008 ; Kralik & Ricchi, 2017 ) for which censored data methods were developed.”
MethodVandenbussche, F., Leeuw, I. D., Vandemeulebroucke, E., & Clercq, K. D. (2009) · Transboundary and Emerging Diseases · doi:10.1111/j.1865-1682.2009.01093.x · Cited by 31
Ricchi, M., Savi, R., Bolzoni, L., Pongolini, S., Grant, I. R., Cicco, C. D., Cerutti, G., Cammi, G., Garbarino, C. A., & Arrigoni, N. (2016) · MicrobiologyOpen · doi:10.1002/mbo3.350 · Cited by 30
Yang, G., Li, J., Lan, T., Dou, L., & Zhang, K. (2022) · Food Chemistry · doi:10.1016/j.foodchem.2022.132875 · Cited by 30
Highly accurate multiprotein detection on a digital ELISA platform
Yang, S., Bi, Q., Zhang, W., Cui, X., Zhou, Y., Yuan, C., & Cui, Y. (2022) · Lab on a Chip · doi:10.1039/d2lc00388k · Cited by 31
Matturro, B., Aulenta, F., Majone, M., Papini, M. P., Tandoi, V., & Rossetti, S. (2012) · New Biotechnology · doi:10.1016/j.nbt.2012.07.006 · Cited by 30
Minarovičová, J., Kaclíková, E., Krascsenicsová, K., Siekel, P., & Kuchta, T. (2009) · Letters in Applied Microbiology · doi:10.1111/j.1472-765x.2009.02708.x · Cited by 29
“The reasons are not fully understood, but probably relate to biochemical as well as stochastic factors (Nogva and Rudi 2004; Burns and Valdivia 2008).”
BackgroundXia, Y. F., Yan, S., Zhang, X., Ma, P., Du, W., Feng, X., & Liu, B. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00031 · Cited by 28
Riedel, T. E., Zimmer-Faust, A. G., Thulsiraj, V., Madi, T., Hanley, K. T., Ebentier, D. L., Byappanahalli, M. N., Layton, B. A., Raith, M. R., Boehm, A. B. B., et al. (2014) · Journal of Environmental Management · doi:10.1016/j.jenvman.2014.01.029 · Cited by 27
Identification of Selected Tuna Species in Commercial Products
Servusová, E., & Piskatá, Z. (2021) · Molecules · doi:10.3390/molecules26041137 · Cited by 26
“In earlier studies, Burns and Valdivia [15] suggested Ct 36 to be a cut-off value in modelling the limit of detection in real-time PCR. Rasmussen et al. [16,17] developed a real-time PCR method to identify salmon and trout species based on the cut-off value of Ct < 25 (for fresh and slightly processed samples) and Ct…”
MethodCOVID-19 and Diagnostic Testing for SARS-CoV-2 by RT-qPCR—Facts and Fallacies
Bustin, S. A., Mueller, R. D., Shipley, G. L., & Nolan, T. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22052459 · Cited by 28
“Crucially, the use of arbitrary Cq cutoffs is inappropriate, because they may be either too low, thus eliminating valid results or too high, thus increasing false-positive results [90].”
BackgroundWang, D., Xinya, J. I. A. O., Jia, H., Cheng, S., Jin, X., Wang, Y., Gao, Y., & Su, X. (2022) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2022.995705 · Cited by 27
“The LoD95% for ddPCR and qPCR is the lowest concentration at which the probability of detecting the target is 95% (Burns and Valdivia, 2008; Kralik and Ricchi, 2017).”
BackgroundCloning and Characterisation of Multiple Ferritin Isoforms in the Atlantic Salmon (Salmo salar)
Lee, J.-H., Pooley, N. J., Mohd-Adnan, A., & Martín, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103729 · Cited by 26
“35, which is generally considered unreliable due to the accumulation of background noise or nonspecific fluorescence at that stage [40].”
BackgroundSchroeder, M. E., Johnson, D. J., Ostlund, E. N., Meier, J., Bounpheng, M. A., & Clavijo, A. (2013) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638713503654 · Cited by 25
“Probit analysis was performed using statistical software j to assess the limit of detection of each assay.(8,9,35) Repeatability of the mRT-qPCR was determined by calculation of the intra- and interassay coefficient of variation (CV) for each pathogen assay.”
MethodLiu, S., Xu, K., Wu, Z., Xie, X., & Feng, J. (2015) · Mitochondrial DNA Part A · doi:10.3109/19401736.2015.1015004 · Cited by 28
“In a previous work, Burns and Valdivia (Burns & Valdivia, 2008) have recognized 36 as cycle cut-off point in modeling the limit of detection in qPCR. Rasmussen et al. (2010; 2011) developed a qPCR method for Salmon and Trout species identification based on the occurrence of a Ct value below 25…”
MethodCheng, T., Henao-Díaz, A., Poonsuk, K., Buckley, A., Geelen, A. V., Lager, K. M., Harmon, K. D., Gauger, P. C., Wang, C., Ambagala, A. P. N., et al. (2021) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2021.105308 · Cited by 25
“The fundamental obstacle to establishing PCR cutoffs and assessing diagnostic performance using a statistical approach is the fact that PCR-negative samples are not assigned a specific Cq value (Burns and Valdivia, 2008; Bustin et al., 2009).”
BackgroundChen, M., He, Q., Tong, Y., & Chen, Z. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.129436 · Cited by 23
Viral etiologies in adult patients with encephalitis in Poland: A prospective single center study
Popiel, M., Perlejewski, K., Bednarska, A., Dzieciątkowski, T., Paciorek, M., Lipowski, D., Jabłonowska, M., Czeszko-Paprocka, H., Bukowska‐Ośko, I., Cortés, K. C., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178481 · Cited by 22
Langlois, V. S., Lopez, M. L. D., Allison, M. J., Imbery, J. J., Couillard, J., Acharya‐Patel, N., Bergman, L. C., Bonderud, M. T., Brochu, M., Castonguay, M., et al. (2025) · Environmental DNA · doi:10.1002/edn3.70139 · Cited by 22
Alazawy, A., & Al-Ajeeli, K. S. (2020) · Veterinary World · doi:10.14202/vetworld.2020.33-39 · Cited by 21
“A previous study [29] found that a high Ct value (above 38 cycles) indicated cross-contamination of amplified nucleic acid or an insufficient amount of nucleic acid for amplification.”
MethodThe current status and future prospects of CRISPR-based detection of monkeypox virus: A review
Chen, Y., Zhao, R., Hu, X., & Wang, X. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343295 · Cited by 22
Novel Application of Nanofluidic Chip Digital PCR for Detection of African Swine Fever Virus
Jia, R., Zhang, G., Liu, H., Chen, Y., Zhou, J., Liu, Y., Ding, P., Wang, Y., Zang, W., & Wang, A. (2021) · Frontiers in Veterinary Science · doi:10.3389/fvets.2020.621840 · Cited by 21
“Then, the B646L gene was recombined with pFastBacI vector (Promega, USA) and transformed into DH5α (Takara, Dalian, China).”
MethodInfluentialRobène-Soustrade, I., Perret, M., Jouen, E., Escalon, A., Maillot, M.-V., Chabirand, A., Moreau, A., Laurent, A., Chiroleu, F., & Pruvost, O. (2015) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2015.04.017 · Cited by 21
Keyvan, K., Sohrabi, M. R., & Motiee, F. (2021) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2021.119429 · Cited by 20
Luo, X., Qin, X., Chen, D., Liu, Z., Zhang, K., & Hu, D. (2019) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.10134 · Cited by 20
Robène-Soustrade, I., Maillot-Lebon, V., Chabirand, A., Moreau, A., Becker, N., Moumène, A., Rieux, A., Campos, P. E., Gagnevin, L., Gaudeul, M., et al. (2020) · BMC Microbiology · doi:10.1186/s12866-020-01972-8 · Cited by 20
Zámečník, J., Krsková, L., Háček, J., Štětkářová, I., & Krbec, M. (2016) · Molecular Medicine Reports · doi:10.3892/mmr.2016.5927 · Cited by 22
“In the remaining samples, expression was near the detection limit, with Cq values ranging between 37 and 47; however, the majority of these results should also be interpreted as negative, since Cq values >40 approach the sensitivity limits of the RT-qPCR system (31,32).”
Gene expression analysis by real-time PCR: Experimental demonstration of PCR detection limits
Bernardo, V. G., Pinto, L. F. R., & Albano, R. M. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.09.029 · Cited by 19
Kerachian, M. A., Azghandi, M., Javadmanesh, A., Ghaffarzadegan, K., & Mozaffari‐Jovin, S. (2020) · Cellular Oncology · doi:10.1007/s13402-020-00536-2 · Cited by 19
“The LoD was defined as the lowest copy number that yields a detectable PCR amplification product with a probability of 95% [13].”
BackgroundMethodAndrew, A., Citartan, M., Wong, K. A., Tang, T., Sum., H., & Ch’ng, E. S. (2023) · Microbiology Spectrum · doi:10.1128/spectrum.00088-23 · Cited by 18
“Selecting a cutoff value is important to minimize the probability of false-positive or false-negative results (32).”
BackgroundEvaluation of real-time PCR results at the limit of detection
Waiblinger, H., Graf, N. M., Broll, H., Grohmann, L., & Pietsch, K. (2011) · Journal of Consumer Protection and Food Safety · doi:10.1007/s00003-011-0669-4 · Cited by 21
“Burns and Valdivia (2008) described an approach to model the LOD using computer simulations as a function of replication levels and cycle threshold values.”
MethodPrado, M., Fumière, O., Boix, A., Marien, A., Berben, G., & von Holst, C. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2796-7 · Cited by 18
Martín, B., Garriga, M., & Aymerich, T. (2012) · Food Control · doi:10.1016/j.foodcont.2012.03.010 · Cited by 18
Determination of cycle cut off in real‐time PCR for the detection of regulated plant pathogens
Chandelier, A., Planchon, V., & Oger, R. (2010) · EPPO Bulletin · doi:10.1111/j.1365-2338.2009.02354.x · Cited by 18
Steele, N. M., Williamson, J. H., Thresher, R. R., Laven, R. A., & HILLERTON, J. E. (2017) · Journal of Dairy Science · doi:10.3168/jds.2016-11752 · Cited by 18
“A high Ct may be generated through cross-contamination, by nonspecific amplification of background DNA, or through the detection of nonviable bacteria (Burns and Valdivia, 2008).”
BackgroundA New Molecular Detection System for Canine Distemper Virus Based on a Double-Check Strategy
Halecker, S., Bock, S., Beer, M., & Hoffmann, B. (2021) · Viruses · doi:10.3390/v13081632 · Cited by 17
“The LOD was determined as the virus titer in GE copies per μL that positively detects 95% of the replicates by the selected PCR assay [33,34].”
MethodAdamek, M., Opelz, G., Klein, K., Morath, C. P., & Tran, T. H. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0622 · Cited by 17
Vandemeulebroucke, E., Clercq, K. D., der Stede, Y. V., & Vandenbussche, F. (2010) · Journal of Virological Methods · doi:10.1016/j.jviromet.2010.01.007 · Cited by 17
Dincau, B. M., Lee, Y.-K., Kim, J., & Yeo, W. (2017) · Sensors · doi:10.3390/s17102316 · Cited by 18
“In addition, these methods heavily rely on conventional detection using plaque assay [49] or real-time quantitative polymerase chain reaction (RT-qPCR) [50,52].”
BackgroundInfluentialLiang, L., Chen, M., Hu, O., He, Q., & Chen, Z. (2022) · Talanta · doi:10.1016/j.talanta.2022.123996 · Cited by 15
A Real-Time PCR Assay to Detect and Quantify Root-Knot Nematodes from Soil Extracts
Hodson, A. K., Celayir, T., & Alonso, A. Q. (2022) · Plant Disease · doi:10.1094/pdis-10-22-2431-re · Cited by 15
Rowe, C. J., Mang, J., Huang, B. X., Dommaraju, K., Potter, B. K., Schobel, S., Gann, E. R., & Davis, T. A. (2023) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2023.103878 · Cited by 16
Boyer, T. C., Hanson, T., & Singer, R. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064900 · Cited by 18
“Past studies that have used qPCR to measure antibiotic resistance gene quantities in agricultural samples often do not provide the LOQ of their assays, nor do they discuss whether or not censoring was present in their data sets [17225].”
BackgroundInfluentialSensitive DNA-based allergen detection depends on food matrix and DNA isolation method
Kenk, M., Panter, S., Engler-Blum, G., & Bergemann, J. (2011) · European Food Research and Technology · doi:10.1007/s00217-011-1639-x · Cited by 15
“The limit of detection (LOD) can be defined as the minimal amount of target DNA which is still detectable with a confidence of 95% [20].”
BackgroundSana, S., Williams, C. F., Hardouin, E. A., Blake, A., Davison, P. I., Pegg, J., Paley, R. K., Zhang, T., & Andreou, D. (2018) · International Journal for Parasitology · doi:10.1016/j.ijpara.2017.11.002 · Cited by 15
Bauer, T., Kirschbaum, K., Panter, S., Kenk, M., & Bergemann, J. (2011) · Journal of AOAC International · doi:10.5740/jaoacint.10-257 · Cited by 15
Byaruhanga, C., Makgabo, S. M., Choopa, C. N., Mulandane, F. C., Vorster, I., Troskie, M., Chaisi, M. E., & Collins, N. E. (2022) · Ticks and Tick-borne Diseases · doi:10.1016/j.ttbdis.2022.102084 · Cited by 13
Kaminska, P. S., Kulakhmetovna, Y. A., Murawska, E., Swiecicki, J., Fiedoruk, K., Bideshi, D. K., & Święcicka, I. (2014) · FEMS Microbiology Letters · doi:10.1111/1574-6968.12503 · Cited by 13
“…the same isolate, and the cycle cutoff was assessed as the PCR cycle number above which any response value (CT) was considered a false-positive (Burns & Valdivia, 2008), and was determined for each gene separately from the dataset corresponding to the negative strains and negative control (see…”
MethodAdams, D. R., Stensland, W. R., Wang, C. H., O'Connor, A. M. C., Trampel, D. W., Harmon, K. M., Strait, E. L., & Frana, T. S. (2013) · Avian Diseases · doi:10.1637/10279-061312-reg.1 · Cited by 13
“degradation of the probe-based fluorophore (6,7), that is, a false”
BackgroundGentilini, F., Zanoni, R. G., Zambon, E., & Turba, M. E. (2016) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638716672503 · Cited by 13
“This translates into >50% probability of testing positive with a 95% level of confidence.(3) The validation experiments were carried out using the genomic (g) DNA of Leptospira interrogans serovar Canicola strain Alarik.”
BackgroundLi, F., Lu, Y., Li, C., Huang, R., Tian, E., Tan, E., Yang, Z., Li, H., & Chao, Z. (2022) · Journal of Stored Products Research · doi:10.1016/j.jspr.2022.101982 · Cited by 12
Real-time PCR, a method fit for detection and quantification of Erwinia amylovora
Dreo, T., Pirc, M., & Ravnikar, M. (2012) · Trees · doi:10.1007/s00468-011-0654-7 · Cited by 12
Metadata
- Authors
- Burns, M., & Valdivia, H.
- Affiliations
- LGC (GB)
- Corresponding author
- Burns, M.
- ORCID
- Burns, M.
- Venue
- European Food Research and Technology
- Published
- 2007-07-19
- Volume
- 226
- Issue
- 6
- Pages
- 1513-1524
- ISSN
- 0373-0174 (ISSN-L)
- 1438-2377
- 1438-2385
- OpenAlex
- W2068874460
- Cited by
- 181
- References
- 29
- Citations by year
- 2026: 5 · 2025: 9 · 2024: 7 · 2023: 11 · 2022: 19 · 2021: 14 · 2020: 19 · 2019: 7 · 2018: 3 · 2017: 13 · 2016: 9 · 2015: 10 · 2014: 7 · 2013: 12 · 2012: 13
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- European Food Research and Technology (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Life Sciences › Agricultural and Biological Sciences › Plant Science › Genetically Modified Organisms Research
- Keywords
- detection limit, real-time quantitative PCR, cycle threshold, sample replication, trace detection, assay validation, non-normal data, heteroscedastic data
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.