Cited by 10Cardiovascular Health and Disease PreventionBlood Pressure and Hypertension StudiesThermoregulation and physiological responses

Effects of carvedilol and atenolol on arterial pulse curves (plethysmography) and finger temperature after hand cooling

Klemsdal, T. O., Mundal, H. H., Gjesdal, K.·1996·European Journal of Clinical Pharmacology

Abstract

Objective In a double-blind, parallel study, the effects of 25 mg carvedilol and 50 mg atenolol on peripheral finger circulation and arterial pulse curve configuration were compared.Methods Healthy volunteers (n = 17) were examined at baseline and for 15 min after 60 s of hand cooling in ice-water. Finger temperature and digital plethysmography were recorded each minute from the cooled and the control hands. Measurements were also made before and 2 h after drug administration.Results Blood pressure declined from 120/86 to 108/74 mm Hg after atenolol (n = 9), and from 122/88 to 108/73 mm Hg after carvedilol (n = 8). In both groups, baseline finger temperature increased slightly after drug, and a more rapid rise in finger temperature was observed after cooling. There was no group difference in the drug effect on finger temperature, except in the first few minutes after cooling, when temperature recovery was greater after carvedilol. Carvedilol reduced the vasoconstrictor response to local cooling (digital plethysmography), compared both to the value before drug and after atenolol. At rest, carvedilol changed the pulse curves (control hand) towards vasodilatation and high compliance, expressed as a mean change in the relative height of the dicrotic notch of -10.3% versus 0.0% after atenolol.Conclusion Future studies should clarify whether the vasoactive profile of carvedilol may translate into reduced occurrence of cold hands and feet amongst patients treated for hypertension.

Integrity signals

Registry

Crossref · 10.1007/s002280050145

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Klemsdal, T. O., Mundal, H. H., & Gjesdal, K.
Affiliations
Oslo University Hospital (NO)
Venue
European Journal of Clinical Pharmacology
Published
1996-07-30
Volume
50
Issue
6
Pages
483-489
ISSN
  • 0031-6970 (ISSN-L)
  • 1432-1041
OpenAlex
W2067086594
Cited by
10
References
21
Citations by year
2016: 1 · 2012: 1
FWCI
0.29
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Clinical Pharmacology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
Keywords
carvedilol, atenolol, beta-blockers, peripheral circulation, finger temperature, hand cooling, digital plethysmography, vasoconstriction, vasodilation, cold hands and feet, hypertension, blood pressure
MeSH terms
Carvedilol, Adrenergic beta-Antagonists, Adult, Atenolol, Blood Circulation, Body Temperature, Carbazoles, Fingers, Hemodynamics, Humans, Hypothermia, Male, Plethysmography, Propanolamines

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›