Cited by 34Cardiovascular Health and Disease PreventionNon-Invasive Vital Sign MonitoringPeripheral Artery Disease Management

Digital pulse plethysmography (DPG) in studies of the hemodynamic response to nitrates — A survey of recording methods and principles of analysis

Lund, Fredrik·1986·Acta Pharmacologica et Toxicologica

Abstract

Abstract:Digital pulse plethysmography (DPG) has proved a technically simple, noninvasive, sensitive and informative technique for studying the effects of nitroglycerin and other nitrates on peripheral arteries. The importance of performing nitrate evaluation by DPG mainly in elderly subjects is emphasized. On the basis of observations with DPG some indirect conclusions on the effect of nitrates on the coronary arteries are justified. — A review, with recommendations based on own experience, is given of various recording techniques and principles of evaluating quantitatively the digital volume pulse contour, with special reference to the influence of nitrates on the position and appearance of dicrotism. DPG seems to be a convenient, noninvasive and helpful procedure in studies on the development of nitrate tolerance.

Integrity signals

Registry

Crossref · 10.1111/j.1600-0773.1986.tb02551.x

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lund, F.
Affiliations
Karolinska University Hospital (SE)
Corresponding author
Lund, Fredrik
Venue
Acta Pharmacologica et Toxicologica
Publisher
Wiley
Published
1986-11
Volume
59
Issue
S6
Pages
79-96
ISSN
0001-6683 (ISSN-L)
OpenAlex
W1994425225
Cited by
34
References
45
Citations by year
2021: 2 · 2020: 2 · 2018: 1 · 2017: 1 · 2016: 2 · 2014: 1 · 2012: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Acta Pharmacologica et Toxicologica (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Peripheral Artery Disease Management
Keywords
nitrate, nitroglycerin, peripheral arteries, nitrate tolerance, coronary arteries, elderly patients, hemodynamic response
MeSH terms
Fingers, Hemodynamics, Humans, Nitrates, Plethysmography, Regional Blood Flow

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review