Scatter modelling and compensation in emission tomography
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
In nuclear medicine, clinical assessment and diagnosis are generally based on qualitative assessment of the distribution pattern of radiotracers used. In addition, emission tomography (SPECT and PET) imaging methods offer the possibility of quantitative assessment of tracer concentration in vivo to quantify relevant parameters in clinical and research settings, provided accurate correction for the physical degrading factors (e.g. attenuation, scatter, partial volume effects) hampering their quantitative accuracy are applied. This review addresses the problem of Compton scattering as the dominant photon interaction phenomenon in emission tomography and discusses its impact on both the quality of reconstructed clinical images and the accuracy of quantitative analysis. After a general introduction, there is a section in which scatter modelling in uniform and non-uniform media is described in detail. This is followed by an overview of scatter compensation techniques and evaluation strategies used for the assessment of these correction methods. In the process, emphasis is placed on the clinical impact of image degradation due to Compton scattering. This, in turn, stresses the need for implementation of more accurate algorithms in software supplied by scanner manufacturers, although the choice of a general-purpose algorithm or algorithms may be difficult.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evans, R. D., & Beiser, A. (1955) · Cited by 1,814
A practical method for position-dependent Compton-scatter correction in single photon emission CT
Ogawa, K., Harata, Y., Ichihara, T., Kubo, A., & Hashimoto, S. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97591 · Cited by 616
Improved SPECT quantification using compensation for scattered photons.
Jaszczak, R. J., Kl, G., Floyd, C. E., Harris, C. C., & Coleman, R. E. (1984) · PubMed · Cited by 555
New, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Model-based scatter correction for fully 3D PET
Ollinger, J. M. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/012 · Cited by 393
Determination of the attenuation map in emission tomography.
Zaidi, H., & Hasegawa, B. H. (2003) · PubMed · Cited by 350
Self-citationQuantification of Brain Function Using PET
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-389760-2.x5000-2 · Cited by 321
Relevance of accurate Monte Carlo modeling in nuclear medical imaging
Zaidi, H. (1999) · Medical Physics · doi:10.1118/1.598559 · Cited by 279 · cited 1×
“However, caution must be exercised to avoid errors in the simulation process, and verification via comparison with experimental and patient data is crucial [ 99 ].”
MethodSelf-citationBarrett, H. H., Denny, J. L., Wagner, R. F., & Myers, K. J. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.000834 · Cited by 243 · cited 1×
“Well-established figures of merit known to have a large influence on many types of task performance are generally used to assess image quality [ 95 ].”
BackgroundZaidi, H., Montandon, M.-L., & Slosman, D. O. (2003) · Medical Physics · doi:10.1118/1.1569270 · Cited by 233 · cited 1×
“It has also been shown that the attenuation map to be used as input for estimation of the scatter distributions can be derived from magnetic resonance images in brain PET scanning [ 84 ].”
MethodSelf-citationA new method for modeling the spatially-variant, object-dependent scatter response function in SPECT
Frey, E. C., & Tsui, B. M. W. (2002) · 1996 IEEE Nuclear Science Symposium. Conference Record · doi:10.1109/nssmic.1996.591559 · Cited by 232
A convolution-subtraction scatter correction method for 3D PET
Bailey, D. L., & Meikle, S. R. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/009 · Cited by 228
The Theory and Practice of 3D PET
(1998) · Springer eBooks · doi:10.1007/978-94-017-3475-2 · Cited by 223
Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging
Watson, C. C., Newport, D., Casey, M. E., deKemp, R. A., Beanlands, R. S., & Schmand, M. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.554831 · Cited by 218 · cited 2×
“A single-scatter simulation (SSS) technique for scatter correction where the mean scatter contribution to the net true coincidence data is estimated by simulating radiation transport through the object was also suggested and validated using human and chest phantom studies [ 32 ].”
MethodRosenthal, M. S., Cullom, J., Hawkins, W. G., Moore, S. C., Tsui, B. M. W., & Yester, M. V. (1995) · PubMed · Cited by 210
Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation
Beekman, F. J., de Jong, H. W. A. M., & van Geloven, S. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803130 · Cited by 197
Positon emission tomography: basic science and clinical practice
Valk, P., Bayley, D. L., Dw, T., & Maisey, M. (2008) · Cited by 195
A transmission-dependent method for scatter correction in SPECT.
Meikle, S. R., Hutton, B. F., & Bailey, D. L. (1994) · PubMed · Cited by 183
Efficient object scatter correction algorithm for third and fourth generation CT scanners
Ohnesorge, B. M., Flohr, T. G., & Klingenbeck-Regn, K. W. (1999) · European Radiology · doi:10.1007/s003300050710 · Cited by 180 · cited 1×
“Similar approaches are also being developed for X-ray CT imaging [ 108 ], which is desirable on dual-modality imaging systems offering the possibility to determine an appropriately scaled patient-specific attenuation map for correcting the emission data.”
Correction for scatter in 3D brain PET using a dual energy window method
Grootoonk, S., Spinks, T. J., Sashin, D., Spyrou, N. M., & Jones, T. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/12/013 · Cited by 167
PET/CT: a new imaging technology in nuclear medicine
Sch�der, H., Erdi, Y. E., Larson, S. M., & Yeung, H. W. D. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1299-6 · Cited by 160
Kadrmas, D. J., Frey, E. C., Karimi, S., & Tsui, B. M. W. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/014 · Cited by 136
Buvat, I., Rodríguez‐Villafuerte, M., Todd-Pokropek, A. E., Benali, H., & Paola, R. D. (1995) · PubMed · Cited by 125
King, M. A., Tsui, B. M. W., Pan, T., Glick, S. J., & Soares, E. J. (1996) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(96)90024-0 · Cited by 119 · cited 2×
“A general idea of the magnitude of scatter in myocardial imaging is an estimate that the ratio of scattered to unscattered (primary) counts, SP, is approximately 0.34 for 99m Tc and 0.95 for 201 Tl [ 14 ].”
BackgroundMethodInfluentialComparison of four scatter correction methods using Monte Carlo simulated source distributions.
Ljungberg, M. H., King, M. A., Hádemenos, G. J., & Strand, S. (1994) · PubMed · Cited by 108
Narita, Y., Eberl, S., Iida, H., Hutton, B. F., Braun, M., Nakamura, T., & Bautovich, G. J. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/017 · Cited by 107
Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation study
Beekman, F. J., Kamphuis, C., & Frey, E. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/8/011 · Cited by 106
Kamphuis, C., Beekman, F. J., van Rijk, P. P., & Viergever, M. A. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050188 · Cited by 84
Fakhri, G. N. E., Buvat, I., Benali, H., et al. (2000) · PubMed · Cited by 78
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
Ewell, L. (2003) · Medical Physics · doi:10.1118/1.1603742 · Cited by 77 · cited 1×
“Many general-purpose and dedicated Monte Carlo programs have been in use in the field of nuclear imaging, with many of them available in the public domain [97, 98 ].”
BackgroundOptimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study.
Sankaran, S., Frey, E. C., Gilland, K. L., & Tsui, B. M. W. (2002) · PubMed · Cited by 76
Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging.
Dewaraja, Y. K., Ljungberg, M. H., & Koral, K. F. (2000) · PubMed · Cited by 75
Self-citationKoral, K. F., Dewaraja, Y. K., Li, J., Lin, Q., Regan, D., Zasadny, K. R., Rommelfanger, S. G., Francis, I. R., Kaminski, M. S., & Wahl, R. L. (2003) · PubMed · Cited by 75
Self-citationObjective Assessment of Image Quality
Kupinski, M. A., & Clarkson, E. W. (2007) · Springer eBooks · doi:10.1007/0-387-25294-0_5 · Cited by 72
Numerical study of multigrid implementations of some iterative image reconstruction algorithms
Pan, T., & Yagle, A. E. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108592 · Cited by 67 · cited 1×
“This non-uniform convergence property is further emphasised and demonstrated by Fourier analysis of the ML-EM algorithm [ 89 ] and successive iterations of inverse Monte Carlo-based reconstructions [20].”
MethodWerling, A., Bublitz, O., Doll, J., Adam, L.-E., & Brix, G. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/16/310 · Cited by 66 · cited 2×
“In the study by Werling et al. [ 88 ], the preliminary results obtained using a fast implementation of the SSS algorithm [83] were not satisfactory, and thus spurred further research to incorporate a more accurate model that took into account multiple scatters.”
ResultParameterization of a model-based 3-D PET scatter correction
Wollenweber, S. D. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.1039554 · Cited by 47 · cited 1×
“Parameterisation of a fast implementation of this algorithm has recently been reported [ 82 ].”
MethodKim, K. M., Varrone, A., Watabe, H., Shidahara, M., Fujita, M., Innis, R. B., & Iida, H. (2003) · PubMed · Cited by 44
Narita, Y., Iida, H., Ebert, S., & Nakamura, T. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.656453 · Cited by 39
Accurate scatter compensation using neural networks in radionuclide imaging
Ogawa, K., & Nishizaki, N. (1993) · IEEE Transactions on Nuclear Science · doi:10.1109/23.256705 · Cited by 33 · cited 1×
“These were introduced for scatter correction in 1993 [ 60 ].”
BackgroundPan, T.-S., King, M. A., Luo, D.-S., Dahlberg, S. T., & Villegas, B. J. (1997) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(97)90048-9 · Cited by 33
New, faster, image-based scatter correction for 3D PET
Watson, C. C. (2003) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1999.842888 · Cited by 28
Fujita, M., Varrone, A., Kim, K. M., Watabe, H., Zoghbi, S. S., Seneca, N. M., Tipre, D. N., Seibyl, J. P., Innis, R. B., & Iida, H. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1431-7 · Cited by 19
Maksud, P., Fertil, B., Rica, C. I. A. T. N. C., Fakhri, G. E., & Aurengo, A. (1998) · PubMed · Cited by 19
Monte Carlo in SPECT Scatter Correction
Koral, K. F., & Dewaraja, Y. K. (2012) · Series in medical physics and biomedical engineering · doi:10.1201/b13073-13 · Cited by 4
Self-citation
Cited by
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
Self-citationEANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
Hesse, B., Tägil, K., Cuocolo, A., Anagnostopoulos, C., Bardiés, M., Bax, J., Bengel, F., Busemann Sokole, E., Davies, G., Dondi, M., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1779-y · Cited by 527
Flotats, A., Carrió, I., Agostini, D., Le Guludec, D., Marcassa, C., Schaffers, M., Somsen, G. A., Unlu, M., & Verberne, H. J. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1491-4 · Cited by 339
Recent Advances in SPECT Imaging
Madsen, M. T. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.032680 · Cited by 338
The promise of artificial intelligence and deep learning in PET and SPECT imaging
Arabi, H., AkhavanAllaf, A., Sanaat, A., Shiri, I., & Zaidi, H. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.008 · Cited by 268
Self-citation
Metadata
- Authors
- Zaidi, H., & Koral, K. F.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2004-05-01
- Volume
- 31
- Issue
- 5
- Pages
- 761-782
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2112136242
- Cited by
- 214
- References
- 45
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.