Harmonizing SUVs in multicentre trials when using different generation PET systems: prospective validation in non-small cell lung cancer patients
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: We prospectively evaluated whether a strategy using point spread function (PSF) reconstruction for both diagnostic and quantitative analysis in non-small cell lung cancer (NSCLC) patients meets the European Association of Nuclear Medicine (EANM) guidelines for harmonization of quantitative values. METHODS: The NEMA NU-2 phantom was used to determine the optimal filter to apply to PSF-reconstructed images in order to obtain recovery coefficients (RCs) fulfilling the EANM guidelines for tumour positron emission tomography (PET) imaging (PSF(EANM)). PET data of 52 consecutive NSCLC patients were reconstructed with unfiltered PSF reconstruction (PSF(allpass)), PSF(EANM) and with a conventional ordered subset expectation maximization (OSEM) algorithm known to meet EANM guidelines. To mimic a situation in which a patient would undergo pre- and post-therapy PET scans on different generation PET systems, standardized uptake values (SUVs) for OSEM reconstruction were compared to SUVs for PSF(EANM) and PSF(allpass) reconstruction. RESULTS: Overall, in 195 lesions, Bland-Altman analysis demonstrated that the mean ratio between PSF(EANM) and OSEM data was 1.03 [95% confidence interval (CI) 0.94-1.12] and 1.02 (95% CI 0.90-1.14) for SUV(max) and SUV(mean), respectively. No difference was noticed when analysing lesions based on their size and location or on patient body habitus and image noise. Ten patients (84 lesions) underwent two PET scans for response monitoring. Using the European Organization for Research and Treatment of Cancer (EORTC) criteria, there was an almost perfect agreement between OSEM(PET1)/OSEM(PET2) (current standard) and OSEM(PET1)/PSF(EANM-PET2) or PSF(EANM-PET1)/OSEM(PET2) with kappa values of 0.95 (95% CI 0.91-1.00) and 0.99 (95% CI 0.96-1.00), respectively. The use of PSF(allpass) either for pre- or post-treatment (i.e. OSEM(PET1)/PSF(allpass-PET2) or PSF(allpass-PET1)/OSEM(PET2)) showed considerably less agreement with kappa values of 0.75 (95% CI 0.67-0.83) and 0.86 (95% CI 0.78-0.94), respectively. CONCLUSION: Protocol-optimized images and compliance with EANM guidelines allowed for a reliable pre- and post-therapy evaluation when using different generation PET systems. These data obtained in NSCLC patients could be extrapolated to other solid tumours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Impact of Time-of-Flight on PET Tumor Detection
Kadrmas, D. J., Casey, M. E., Conti, M., Jakoby, B. W., Lois, C., & Townsend, D. W. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.063016 · Cited by 277 · cited 1×
“In our department, PET images are reconstructed with a PSF reconstruction algorithm (HD; TrueX, Siemens Medical Solutions; 3 iterations and 21 subsets) without filtering (PSFallpass), as modelling the PSF during iterative reconstruction introduces correlations between neighbouring voxels in a manner similar to smoothi…”
MethodImpact of the Definition of Peak Standardized Uptake Value on Quantification of Treatment Response
Vanderhoek, M., Perlman, S. B., & Jeraj, R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.093443 · Cited by 188
Variations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136
Clinical evaluation of PET image reconstruction using a spatial resolution model
Andersen, F. L., Klausen, T. L., Loft, A., Beyer, T., & Holm, S. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.11.015 · Cited by 62
Cited by
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
“Image quality and recovery coefficient harmonisation (IQRC) Although correct cross-calibration is guaranteed using the QC procedure described above, differences in SUV quantification may still occur between centres as a result of differences in the reconstruction and data analysis methodology [60, 100].”
Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3740-2 · Cited by 344
Self-citationEANM/EARL FDG-PET/CT accreditation - summary results from the first 200 accredited imaging systems
Kaalep, A., Sera, T., Oyen, W., Krause, B. J., Chiti, A., Liu, Y., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3853-7 · Cited by 174
Feasibility of state of the art PET/CT systems performance harmonisation
Kaalep, A., Sera, T., Rijnsdorp, S., Yaqub, M., Talsma, A., Lodge, M. A., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3977-4 · Cited by 160
Quak, E., Le Roux, P.-Y., Hofman, M. S., Robin, P., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaun, P.-Y., Hicks, R. J., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3128-0 · Cited by 107
“It has been recently shown that it is possible to harmonize SUVs produced by an advanced reconstruction algorithm, such as PSF reconstruction, for example, to EANM standards by applying a filter during the reconstruction [9].”
MethodSelf-citation
Metadata
- Authors
- Lasnon, C., Desmonts, C., Quak, E., Gervais, R., Do, P., Dubos-Arvis, C., & Aide, N.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2013-04-06
- Volume
- 40
- Issue
- 7
- Pages
- 985-996
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2095517319
- Cited by
- 125
- References
- 5
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Harmonizing SUVs in multicentre trials when using different generation PET systems: prospective validation in non-small cell lung cancer patients. https://app.cochat.ai/papers/10.1007/s00259-013-2391-1
- The paper
- Lasnon, C., Desmonts, C., Quak, E., Gervais, R., Do, P., Dubos-Arvis, C., & Aide, N. (2013). Harmonizing SUVs in multicentre trials when using different generation PET systems: prospective validation in non-small cell lung cancer patients. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-013-2391-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.