Characterization of PET/CT images using texture analysis: the past, the present… any future?
Open accessThe DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Abstract
After seminal papers over the period 2009 – 2011, the use of texture analysis of PET/CT images for quantification of intratumour uptake heterogeneity has received increasing attention in the last 4 years. Results are difficult to compare due to the heterogeneity of studies and lack of standardization. There are also numerous challenges to address. In this review we provide critical insights into the recent development of texture analysis for quantifying the heterogeneity in PET/CT images, identify issues and challenges, and offer recommendations for the use of texture analysis in clinical research. Numerous potentially confounding issues have been identified, related to the complex workflow for the calculation of textural features, and the dependency of features on various factors such as acquisition, image reconstruction, preprocessing, functional volume segmentation, and methods of establishing and quantifying correspondences with genomic and clinical metrics of interest. A lack of understanding of what the features may represent in terms of the underlying pathophysiological processes and the variability of technical implementation practices makes comparing results in the literature challenging, if not impossible. Since progress as a field requires pooling results, there is an urgent need for standardization and recommendations/guidelines to enable the field to move forward. We provide a list of correct formulae for usual features and recommendations regarding implementation. Studies on larger cohorts with robust statistical analysis and machine learning approaches are promising directions to evaluate the potential of this approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Self-citationIntratumor Heterogeneity and Branched Evolution Revealed by Multiregion Sequencing
Gerlinger, M., Rowan, A. J., Horswell, S., Larkin, J., Endesfelder, D., Gronroos, E., Martinez, P., Matthews, N., Stewart, A., Tarpey, P., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113205 · Cited by 7,774 · cited 1×
“Tumours are heterogeneous entities at all scales (macroscopic, physiological, microscopic, genetic) [1].”
BackgroundRadiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132 · cited 2×
“Regarding the low-dose CT component of PET/CT, usually without contrast enhancement, heterogeneity refers to the variability in tissue density, which may result from spatially varying vascularization, necrosis or cellularity, as well as the proportions of fat, air and water [7].”
BackgroundMethod(2012) · The Scientific World JOURNAL · doi:10.1100/tswj · Cited by 2,595
Dwan, K., Gamble, C., Williamson, P. R., Kirkham, J. J., & the Reporting Bias Group (2013) · PLoS ONE · doi:10.1371/journal.pone.0066844 · Cited by 1,127
Machine Learning methods for Quantitative Radiomic Biomarkers
Parmar, C., Grossmann, P., Bussink, J., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep13087 · Cited by 1,019
Vallières, M., Freeman, C. R., Skamene, S. R., & El Naqa, I. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5471 · Cited by 897
Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice?
Davnall, F., Yip, C. S. P., Ljungqvist, G., Selmi, M., Ng, F., Sanghera, B., Ganeshan, B., Miles, K. A., Cook, G. J., & Goh, V. (2012) · Insights into Imaging · doi:10.1007/s13244-012-0196-6 · Cited by 878 · cited 1×
“As a multimodal imaging modality, PET/CT is a promising tool for noninvasive exploration of intratumour heterogeneity at the macroscopic scale in both the anatomical and functional dimensions [2, 3].”
MethodHow to Make More Published Research True
Ioannidis, J. P. A. (2014) · PLoS Medicine · doi:10.1371/journal.pmed.1001747 · Cited by 760
Cited by
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationRadiomics: the facts and the challenges of image analysis
Rizzo, S., Botta, F., Raimondi, S., Origgi, D., Fanciullo, C., Morganti, A. G., & Bellomi, M. (2018) · European Radiology Experimental · doi:10.1186/s41747-018-0068-z · Cited by 1,054
Berenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S. (2018) · Radiology · doi:10.1148/radiol.2018172361 · Cited by 622
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Radiomics strategies for risk assessment of tumour failure in head-and-neck cancer
Vallières, M., Kay-Rivest, E., Perrin, L. J., Liem, X., Furstoss, C., Aerts, H. J. W. L., Khaouam, N., Nguyen-Tan, P. F., Wang, C.-S., Sultanem, K., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-10371-5 · Cited by 542
Beyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3740-2 · Cited by 344
A review in radiomics: Making personalized medicine a reality via routine imaging
Guiot, J., Vaidyanathan, A., Deprez, L., Zerka, F., Danthine, D., Frix, A., Lambin, P., Bottari, F., Tsoutzidis, N., Miraglio, B., et al. (2022) · Medicinal Research Reviews · doi:10.1002/med.21846 · Cited by 337
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Roadmap toward the 10 ps time-of-flight PET challenge
Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab9500 · Cited by 258
Self-citationLucia, F., Visvikis, D., Desseroit, M.-C., Miranda, O., Malhaire, J.-P., Robin, P., Pradier, O., Hatt, M., & Schick, U. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3898-7 · Cited by 245
“To confirm the predictive value of the features identified in a cohort, validation on an external cohort of patients is considered the gold standard [8, 29].”
BackgroundInfluentialSelf-citationPapadimitroulas, P., Brocki, L., Christopher Chung, N., Marchadour, W., Vermet, F., Gaubert, L., Eleftheriadis, V., Plachouris, D., Visvikis, D., Kagadis, G. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.009 · Cited by 226
“Another advantage of multicenter studies is the inherent variability in the data, which can make the cohort more representative and thus lead to more robust inference of models [127,128].”
BackgroundSelf-citationLeger, S., Zwanenburg, A., Pilz, K., Lohaus, F., Linge, A., Zöphel, K., Kotzerke, J., Schreiber, A., Tinhofer, I., Budach, V., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-13448-3 · Cited by 215
“0 otherwise (6) 3 train valid train valid ∪ ∪ γ = μ > α μ < α μ < α μ > α .”
Voxel size and gray level normalization of CT radiomic features in lung cancer
Shafiq-ul-Hassan, M., Latifi, K., Zhang, G., Ullah, G., Gillies, R., & Moros, E. (2018) · Scientific Reports · doi:10.1038/s41598-018-28895-9 · Cited by 215
Shiri, I., Rahmim, A., Ghaffarian, P., Geramifar, P., Abdollahi, H., & Bitarafan-Rajabi, A. (2017) · European Radiology · doi:10.1007/s00330-017-4859-z · Cited by 204
Influence of inter-observer delineation variability on radiomics stability in different tumor sites
Pavic, M., Bogowicz, M., Würms, X., Glatz, S., Finazzi, T., Riesterer, O., Roesch, J., Rudofsky, L., Friess, M., Veit-Haibach, P., et al. (2018) · Acta Oncologica · doi:10.1080/0284186x.2018.1445283 · Cited by 203
Syed, M., Flechsig, P., Liermann, J., Windisch, P., Staudinger, F., Akbaba, S., Koerber, S. A., Freudlsperger, C., Plinkert, P. K., Debus, J., et al. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04859-y · Cited by 164
“The next promising advancement appears in the knowledge that intra-tumoural uptake-intensity of PET tracers reflects the grade of malignancy [26, 27].”
BackgroundHarmonization strategies for multicenter radiomics investigations
Da-Ano, R., Visvikis, D., & Hatt, M. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aba798 · Cited by 161
“Multicenter studies are needed to demonstrate the clinical potential value of radiomics as a prognostic tool (Hatt et al 2017, O’Connor et al 2017).”
BackgroundSelf-citationDesseroit, M.-C., Tixier, F., Weber, W. A., Siegel, B. A., Cheze Le Rest, C., Visvikis, D., & Hatt, M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180919 · Cited by 160
“…their repeatability in PET with FDG or fluorine-18 fluorothymidine (8,14–17) and in Finally, it has been shown recently that the image quantization step in the calculation of textural features can have an impact on the relationship to other parameters (3) and on the repeatability (17,22) .”
Self-citationCoy, H., Hsieh, K., Wu, W., Nagarajan, M. B., Young, J. R., Douek, M. L., Brown, M. S., Scalzo, F., & Raman, S. S. (2019) · Abdominal Radiology · doi:10.1007/s00261-019-01929-0 · Cited by 110
Prognostic value of FDG-PET radiomics with machine learning in pancreatic cancer
Toyama, Y., Hotta, M., Motoi, F., Takanami, K., Minamimoto, R., & Takase, K. (2020) · Scientific Reports · doi:10.1038/s41598-020-73237-3 · Cited by 75
Reynés‐Llompart, G., Gámez‐Cenzano, C., Vercher‐Conejero, J. L., Sabaté‐Llobera, A., Calvo‐Malvar, N., & Martí‐Climent, J. M. (2018) · Medical Physics · doi:10.1002/mp.12986 · Cited by 55
Metadata
- Authors
- Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2016-06-06
- Volume
- 44
- Issue
- 1
- Pages
- 151-165
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2409456704
- Cited by
- 475
- References
- 102
- FWCI
- 46.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.