Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT
Open accessAbstract
Purpose: To investigate the performance of the new long axial field-of-view (LAFOV) Biograph Vision Quadra PET/CT and a standard axial field-of-view (SAFOV) Biograph Vision 600 PET/CT (both: Siemens Healthineers) system using an intra-patient comparison. Methods: Forty-four patients undergoing routine oncological PET/CT were prospectively included and underwent a same-day dual-scanning protocol following a single administration of either 18 F-FDG (n = 20), 18 F-PSMA-1007 (n = 16) or 68 Ga-DOTA-TOC (n = 8). Half the patients first received a clinically routine examination on the SAFOV (FOV axial 26.3 cm) in continuous bed motion and then immediately afterwards on the LAFOV system (10-min acquisition in list mode, FOV axial 106 cm); the second half underwent scanning in the reverse order. Comparisons between the LAFOV at different emulated scan times (by rebinning list mode data) and the SAFOV were made for target lesion integral activity, signal to noise (SNR), target lesion to background ratio (TBR) and visual image quality. Results: Equivalent target lesion integral activity to the SAFOV acquisitions (16-min duration for a 106 cm FOV) were obtained on the LAFOV in 1.63 ± 0.19 min (mean ± standard error). Equivalent SNR was obtained by 1.82 ± 1.00 min LAFOV acquisitions. No statistically significant differences (p > 0.05) in TBR were observed even for 0.5 min LAFOV examinations. Subjective image quality rated by two physicians confirmed the 10 min LAFOV to be of the highest quality, with equivalence between the LAFOV and the SAFOV at 1.8 ± 0.85 min. By analogy, if the LAFOV scans were maintained at 10 min, proportional reductions in applied radiopharmaceutical could obtain equivalent lesion integral activity for activities under 40 MBq and equivalent doses for the PET component of <1 mSv. Conclusion: Improved image quality, lesion quantification and SNR resulting from higher sensitivity were demonstrated for an LAFOV system in a head-to-head comparison under clinical conditions. The LAFOV system could deliver images of comparable quality and lesion quantification in under 2 min, compared to routine SAFOV acquisition (16 min for equivalent FOV coverage). Alternatively, the LAFOV system could allow for low-dose examination protocols. Shorter LAFOV acquisitions (0.5 min), while of lower visual quality and SNR, were of adequate quality with respect to target lesion identification, suggesting that ultra-fast or low-dose acquisitions can be acceptable in selected settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763
First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*
Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.226498 · Cited by 722
Giesel, F. L., Hadaschik, B., Cardinale, J., Radtke, J., Vinsensia, M., Lehnert, W., Kesch, C., Tolstov, Y., Singer, S., Grabe, N., et al. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3573-4 · Cited by 592
Performance Characteristics of the Digital Biograph Vision PET/CT System
van Sluis, J., de Jong, J., Schaar, J., Noordzij, W., van Snick, P., Dierckx, R., Borra, R., Willemsen, A., & Boellaard, R. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.215418 · Cited by 484
Spencer, B. A., Berg, E., Schmall, J. P., Omidvari, N., Leung, E. K., Abdelhafez, Y. G., Tang, S., Deng, Z., Dong, Y., Lv, Y., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.250597 · Cited by 403
Sandström, M., Velikyan, I., Garske-Román, U., Sörensen, J., Eriksson, B., Granberg, D., Lundqvist, H., Sundin, A., & Lubberink, M. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.120600 · Cited by 161
Nguyen, N. C., Vercher-Conejero, J. L., Sattar, A., Miller, M. A., Maniawski, P. J., Jordan, D. W., Muzic, R. F., Su, K., O’Donnell, J. K., & Faulhaber, P. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.148338 · Cited by 154
Rausch, I., Cal-González, J., Dapra, D., Gallowitsch, H. J., Lind, P., Beyer, T., & Minear, G. (2015) · EJNMMI Physics · doi:10.1186/s40658-015-0132-1 · Cited by 133
Tan, H., Sui, X., Yin, H., Yu, H., Gu, Y., Chen, S., Hu, P., Mao, W., & Shi, H. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05091-4 · Cited by 129
Sher, A., Lacoeuille, F., Fosse, P., Vervueren, L., Cahouet-Vannier, A., Dabli, D., Bouchet, F., & Couturier, O. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0177-8 · Cited by 111
A method to assess image quality for Low-dose PET: analysis of SNR, CNR, bias and image noise
Yan, J., Schaefferkoetter, J. D., Conti, M., & Townsend, D. W. (2016) · Cancer Imaging · doi:10.1186/s40644-016-0086-0 · Cited by 110
Liu, G., Hu, P., Yu, H., Tan, H., Zhang, Y., Yin, H., Hu, Y., Gu, J., & Shi, H. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05173-3 · Cited by 96
Comparison of image quality and lesion detection between digital and analog PET/CT
López-Mora, D. A., Flotats, A., Fuentes-Ocampo, F., Camacho, V., Fernández, A., Ruiz, A., Duch, J., Sizova, M., Domènech, A., Estorch, M., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-4260-z · Cited by 94
Surti, S., Viswanath, V., Daube-Witherspoon, M. E., Conti, M., Casey, M., & Karp, J. S. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.242305 · Cited by 72
Alberts, I., Sachpekidis, C., Prenosil, G., Viscione, M., Bohn, K. P., Mingels, C., Shi, K., Ashar-Oromieh, A., & Rominger, A. (2021) · Annals of Nuclear Medicine · doi:10.1007/s12149-021-01588-6 · Cited by 70
Self-citationvan Sluis, J., Boellaard, R., Dierckx, R., Stormezand, G. N., Glaudemans, A. W. J. M., & Noordzij, W. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.234351 · Cited by 69
Alberts, I., Prenosil, G., Sachpekidis, C., Weitzel, T., Shi, K., Rominger, A., & Afshar‐Oromieh, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04630-y · Cited by 67
Self-citationFuentes-Ocampo, F., López-Mora, D. A., Flotats, A., Paillahueque, G., Camacho, V., Duch, J., Fernández, A., Domènech, A., Estorch, M., & Carrió, I. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4256-0 · Cited by 65
Kunnen, B., Beijst, C., Lam, M. G. E. H., Viergever, M. A., & de Jong, H. W. A. M. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-0283-6 · Cited by 32
Koopman, D., van Osch, J. A. C., Jager, P. L., Tenbergen, C. J. A., Knollema, S., Slump, C. H., & van Dalen, J. A. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0158-z · Cited by 31
Meyer, M., Allenbach, G., Lalonde, M. N., Schaefer, N. G., Prior, J. O., & Gnesin, S. (2020) · Scientific Reports · doi:10.1038/s41598-019-57313-x · Cited by 26
Alberts, I., Hünermund, J., Sachpekidis, C., Mingels, C., Fech, V., Bohn, K. P., Rominger, A., & Afshar‐Oromieh, A. (2021) · European Radiology · doi:10.1007/s00330-021-07870-5 · Cited by 26
Self-citationPrenosil, G. A., Weitzel, T., Fürstner, M., Hentschel, M., Krause, T., Cumming, P. D., Rominger, A., & Klaeser, B. (2020) · PLoS ONE · doi:10.1371/journal.pone.0229560 · Cited by 25
Self-citationLee, H., Paeng, J. C., Hong, S. H., Yoo, H. J., Cheon, G. J., Lee, D. S., Chung, J., & Kang, K. W. (2016) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000561 · Cited by 11
Lesion Detection and Administered Activity
McCready, V. R., Dizdarevic, S., & Beyer, T. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.244020 · Cited by 7
Cited by
Prenosil, G. A., Sari, H., Fürstner, M., Afshar-Oromieh, A., Shi, K., Rominger, A., & Hentschel, M. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.261972 · Cited by 338
Self-citationRadiotheranostics in oncology: Making precision medicine possible
Aboagye, E. O., Barwick, T. D., & Haberkorn, U. (2023) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21768 · Cited by 131
New PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
Metadata
- Authors
- Alberts, I., Hünermund, J.-N., Prenosil, G., Mingels, C., Bohn, K. P., Viscione, M., Sari, H., Vollnberg, B., Shi, K., Afshar-Oromieh, A., & Rominger, A.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2021-04-02
- Volume
- 48
- Issue
- 8
- Pages
- 2395-2404
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W3147126934
- Cited by
- 286
- References
- 27
- FWCI
- 24.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.