Augmented versus Virtual Reality Laparoscopic Simulation: What Is the Difference?: A Comparison of the ProMIS Augmented Reality Laparoscopic Simulator versus LapSim Virtual Reality Laparoscopic Simulator
Open accessThe DOI matches its Crossref record.
Abstract
Background: Virtual reality (VR) is an emerging new modality for laparoscopic skills training; however, most simulators lack realistic haptic feedback. Augmented reality (AR) is a new laparoscopic simulation system offering a combination of physical objects and VR simulation. Laparoscopic instruments are used within an hybrid mannequin on tissue or objects while using video tracking. This study was designed to assess the difference in realism, haptic feedback, and didactic value between AR and VR laparoscopic simulation. Methods: The ProMIS AR and LapSim VR simulators were used in this study. The participants performed a basic skills task and a suturing task on both simulators, after which they filled out a questionnaire about their demographics and their opinion of both simulators scored on a 5‐point Likert scale. The participants were allotted to 3 groups depending on their experience: experts, intermediates and novices. Significant differences were calculated with the paired t‐test. Results: There was general consensus in all groups that the ProMIS AR laparoscopic simulator is more realistic than the LapSim VR laparoscopic simulator in both the basic skills task (mean 4.22 resp. 2.18, P < 0.000) as well as the suturing task (mean 4.15 resp. 1.85, P < 0.000). The ProMIS is regarded as having better haptic feedback (mean 3.92 resp. 1.92, P < 0.000) and as being more useful for training surgical residents (mean 4.51 resp. 2.94, P < 0.000). Conclusions: In comparison with the VR simulator, the AR laparoscopic simulator was regarded by all participants as a better simulator for laparoscopic skills training on all tested features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Virtual reality training for surgical trainees in laparoscopic surgery
Nagendran, M., Gurusamy, K. S., Aggarwal, R., Loizidou, M., & Davidson, B. R. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006575.pub3 · Cited by 593
van der Meijden, O. A. J., & Schijven, M. P. (2009) · Surgical Endoscopy · doi:10.1007/s00464-008-0298-x · Cited by 541
Self-citationA Systematic Review of 10 Years of Augmented Reality Usability Studies: 2005 to 2014
Dey, A., Billinghurst, M., Lindeman, R. W., & Swan, J. E. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00037 · Cited by 434
Shorey, S., & Ng, E. D. (2021) · Nurse Education Today · doi:10.1016/j.nedt.2020.104662 · Cited by 377
Augmented reality in healthcare education: an integrative review
Zhu, E., Hadadgar, A., Masiello, I., & Zary, N. (2014) · PeerJ · doi:10.7717/peerj.469 · Cited by 295
What is going on in augmented reality simulation in laparoscopic surgery?
Botden, S. M. B. I., & Jakimowicz, J. J. (2009) · Surgical Endoscopy · doi:10.1007/s00464-008-0144-1 · Cited by 190
“In a comparison of AR with VR laparoscopic suturing [ 22 ], the ProMIS AR simulator was preferred by far over the VR simulator for training suturing skills.”
MethodInfluentialSelf-citationRagan, E. D. (2010) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres_a_00016 · Cited by 164
Metadata
- Authors
- Botden, S. M. B. I., Buzink, S. N., Schijven, M. P., & Jakimowicz, J. J.
- Venue
- World Journal of Surgery
- Publisher
- Wiley
- Published
- 2007-03-08
- Volume
- 31
- Issue
- 4
- Pages
- 764-772
- ISSN
- 0364-2313 (ISSN-L)
- 1432-2323
- OpenAlex
- W2143068553
- Cited by
- 179
- References
- 0
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.