CoChat

High‐Frequency Gastric Electrical Stimulation for the Treatment of Gastroparesis: A Meta‐Analysis

Open access
O’Grady, Gregory, Egbuji, John U., Du, Peng, Cheng, Leo K., Pullan, Andrew J., Windsor, John A. · 2009 · World Journal of Surgery
Cited by 119

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background & Aims: High‐frequency gastric electrical stimulation (GES) is a relatively new treatment for medically refractory gastroparesis. There have been a number of clinical studies based on the use of a high‐frequency stimulator (Enterra, Medtronic, Minneapolis, MN). A meta‐analysis was performed to evaluate evidence for improved clinical outcome with this device. Methods: A literature search of major medical databases was performed for the period January 1992 to August 2008. Clinical studies involving an implanted high‐frequency GES device were included and reported a range of clinical outcomes. Studies of external, temporary, and/or low‐frequency GES were excluded. Results: Of 13 included studies, 12 lacked controls and only one was blinded and randomized. Following GES, patients reported improvements in total symptom severity score (3/13 studies, mean difference 6.52 [confidence interval—CI: 1.32, 11.73]; P = 0.01), vomiting severity score (4/13, 1.45 [CI: 0.99, 1.91]; P < 0.0001), nausea severity score (4/13, 1.69 [CI: 1.26, 2.12]; P < 0.0001), SF‐36 physical composite score (4/13, 8.05 [CI: 5.01, 11.10]; P < 0.0001), SF‐36 mental composite score (4/13, 8.16 [CI: 4.85, 11.47]; P < 0.0001), requirement for enteral or parenteral nutrition (8/13, OR 5.53 [CI: 2.75, 11.13]; P < 0.001), and 4‐h gastric emptying (5/13, 12.7% [CI: 9.8, 15.6]; P < 0.0001). Weight gain did not reach significance (3/13, 3.68 kg [CI: –0.23, 7.58]; P = 0.07). The device removal or reimplantation rate was 8.3%. Conclusions: Results show substantial benefits for high‐frequency GES in the treatment of gastroparesis. However, caution is necessary in interpreting the results, primarily because of the limitations of uncontrolled studies. Further controlled studies are required to confirm the clinical benefits of high‐frequency GES.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00268-009-0096-1

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
O’Grady, G., Egbuji, J. U., Du, P., Cheng, L. K., Pullan, A. J., & Windsor, J. A.
Venue
World Journal of Surgery
Publisher
Wiley
Published
2009-06-09
Volume
33
Issue
8
Pages
1693-1701
ISSN
  • 0364-2313 (ISSN-L)
  • 1432-2323
OpenAlex
W2119258055
Cited by
119
References
6
FWCI
6.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.