Breast cancer detection using automated whole breast ultrasound and mammography in radiographically dense breasts
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
PURPOSE: Mammography, the standard method of breast cancer screening, misses many cancers, especially in dense-breasted women. We compared the performance and diagnostic yield of mammography alone versus an automated whole breast ultrasound (AWBU) plus mammography in women with dense breasts and/or at elevated risk of breast cancer. METHODS: AWBU screening was tested in 4,419 women having routine mammography ( TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00649337). Cancers occurring during the study and subsequent 1-year follow-up were evaluated. Sensitivity, specificity and positive predictive value (PPV) of biopsy recommendation for mammography alone, AWBU and mammography with AWBU were calculated. RESULTS: Breast cancer detection doubled from 23 to 46 in 6,425 studies using AWBU with mammography, resulting in an increase in diagnostic yield from 3.6 per 1,000 with mammography alone to 7.2 per 1,000 by adding AWBU. PPV for biopsy based on mammography findings was 39.0% and for AWBU 38.4%. The number of detected invasive cancers 10 mm or less in size tripled from 7 to 21 when AWBU findings were added to mammography. CONCLUSION: AWBU resulted in significant cancer detection improvement compared with mammography alone. Additional detection and the smaller size of invasive cancers may justify this technology's expense for women with dense breasts and/or at high risk for breast cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gail, M. H., Brinton, L. A., Byar, D. P., Corle, D. K., Green, S. B., Schairer, C., & Mulvihill, J. J. (1989) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/81.24.1879 · Cited by 3,334 · cited 1×
“Despite progress in identifying risk factors and genetic markers for breast cancer, approximately 70–80% of cases occur in women without known major predictors [1–3].”
BackgroundAmerican Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637
Mammographic Density and the Risk and Detection of Breast Cancer
Boyd, N. F., Guo, H., Martin, L. J., Sun, L., Stone, J., Fishell, E., Jong, R. A., Hislop, G., Chiarelli, A., Minkin, S., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa062790 · Cited by 2,478
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D'Orsi, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa052911 · Cited by 1,940
Kolb, T. M., Lichy, J., & Newhouse, J. H. (2002) · Radiology · doi:10.1148/radiol.2251011667 · Cited by 1,718
Kriege, M., Brekelmans, C. T. M., Boetes, C., Besnard, P. E., Zonderland, H. M., Obdeijn, I. M., Manoliu, R. A., Kok, T., Peterse, H., Tilanus-Linthorst, M. M. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031759 · Cited by 1,687
Berg, W. A. (2008) · JAMA · doi:10.1001/jama.299.18.2151 · Cited by 1,526
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439
Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.6.1741769 · Cited by 1,273
Boyd, N. F., Byng, J. W., Jong, R. A., Fishell, E. K., Little, L. E., Miller, A. B., Lockwood, G. A., Tritchler, D. L., & Yaffe, M. J. (1995) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/87.9.670 · Cited by 1,105
Cited by
Awareness and current knowledge of breast cancer
Akram, M., Iqbal, M., Daniyal, M., & Khan, A. U. (2017) · Biological Research · doi:10.1186/s40659-017-0140-9 · Cited by 1,406
Melnikow, J., Fenton, J. J., Whitlock, E. P., Miglioretti, D. L., Weyrich, M. S., Thompson, J. H., & Shah, K. (2016) · Annals of Internal Medicine · doi:10.7326/m15-1789 · Cited by 376
Breast cancer detection using deep learning: Datasets, methods, and challenges ahead
din, N. M. U., Dar, R. A., Rasool, M., & Assad, A. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106073 · Cited by 363
Pathogenesis, prevention, diagnosis and treatment of breast cancer
Shah, R. (2014) · World Journal of Clinical Oncology · doi:10.5306/wjco.v5.i3.283 · Cited by 329
Ultrasound as the Primary Screening Test for Breast Cancer: Analysis From ACRIN 6666
Berg, W. A., Bandos, A. I., Mendelson, E. B., Lehrer, D., Jong, R. A., & Pisano, E. D. (2016) · Journal of the National Cancer Institute · doi:10.1093/jnci/djv367 · Cited by 309
Screening Breast Ultrasound: Past, Present, and Future
Brem, R. F., Lenihan, M. J., Lieberman, J., & Torrente, J. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.13.12072 · Cited by 307
Breast Cancer Screening and Diagnosis: A Synopsis of the European Breast Guidelines
Schünemann, H. J., Lerda, D., Quinn, C., Follmann, M., Alonso-Coello, P., Rossi, P. G., Lebeau, A., Nyström, L., Broeders, M., Ioannidou-Mouzaka, L., et al. (2020) · Annals of Internal Medicine · doi:10.7326/m19-2125 · Cited by 286
Saba, T. (2020) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2020.06.033 · Cited by 284
Tagliafico, A. S., Calabrese, M., Mariscotti, G., Durando, M., Tosto, S., Monetti, F., Airaldi, S., Bignotti, B., Nori, J., Bagni, A., et al. (2016) · Journal of Clinical Oncology · doi:10.1200/jco.2015.63.4147 · Cited by 239
Willmann, J. K., Bonomo, L., Testa, A. C., Rinaldi, P., Rindi, G., Valluru, K. S., Petrone, G., Martini, M., Lutz, A. M., & Gambhir, S. S. (2017) · Journal of Clinical Oncology · doi:10.1200/jco.2016.70.8594 · Cited by 235
Niell, B. L., Freer, P. E., Weinfurtner, R. J., Arleo, E. K., & Drukteinis, J. S. (2017) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2017.06.004 · Cited by 226
Sprague, B. L., Stout, N. K., Schechter, C., van Ravesteyn, N. T., Cevik, M., Alagoz, O., Lee, C. I., van den Broek, J. J., Miglioretti, D. L., Mandelblatt, J. S., et al. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0692 · Cited by 217
Breast density implications and supplemental screening
Vourtsis, A., & Berg, W. A. (2019) · European Radiology · doi:10.1007/s00330-018-5668-8 · Cited by 217
Breast Image Analysis for Risk Assessment, Detection, Diagnosis, and Treatment of Cancer
Giger, M. L., Karssemeijer, N., & Schnabel, J. A. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152416 · Cited by 206
Deeply-Supervised Networks With Threshold Loss for Cancer Detection in Automated Breast Ultrasound
Wang, Y., Wang, N., Xu, M., Yu, J., Qin, C., Luo, X., Yang, X., Wang, T., Li, A., & Ni, D. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2936500 · Cited by 180
Survey of deep learning in breast cancer image analysis
Debelee, T. G., Schwenker, F., Ibenthal, A., & Yohannes, D. (2020) · Evolving Systems · doi:10.1007/s12530-019-09297-2 · Cited by 177
Detection and classification the breast tumors using mask R-CNN on sonograms
Chiao, J.-Y., Chen, K.-Y., Liao, K. Y.-K., Hsieh, P.-H., Zhang, G., & Huang, T.-C. (2019) · Medicine · doi:10.1097/md.0000000000015200 · Cited by 176
Zhang, L., Tang, M., Min, Z., Lu, J., Lei, X., & Zhang, X. (2016) · Acta Radiologica · doi:10.1177/0284185115597265 · Cited by 169
Breast ultrasound region of interest detection and lesion localisation
Yap, M. H., Goyal, M., Osman, F., Martí, R., Denton, E., Juette, A., & Zwiggelaar, R. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2020.101880 · Cited by 161
Sree, S. V. (2011) · World Journal of Clinical Oncology · doi:10.5306/wjco.v2.i4.171 · Cited by 158
Ciritsis, A., Rossi, C., Eberhard, M., Marcon, M., Becker, A. S., & Boss, A. (2019) · European Radiology · doi:10.1007/s00330-019-06118-7 · Cited by 117
Choi, J. S., Han, B.-K., Ko, E. S., Bae, J. M., Ko, E. Y., Song, S. H., Kwon, M.-R., Shin, J. H., & Hahn, S. Y. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0530 · Cited by 104
RETRACTED ARTICLE: Deep learning approaches to detect breast cancer: a comprehensive review
Sharafaddini, A. M., Esfahani, K. K., & Mansouri, N. (2024) · Multimedia Tools and Applications · doi:10.1007/s11042-024-20011-6 · Cited by 104
RetractedSYNTHESIS OF TAMOXIFEN DERIVATIVES AND THEIR BIOLOGICAL ACTIVITIES
Tandon, N., Tandon, N., & Tandon, R. (2020) · PLANT ARCHIVES · doi:10.51470/plantarchives.2021.v21.s1.376
Metadata
- Authors
- Kelly, K. M., Dean, J., Comulada, W. S., & Lee, S.-J.
- Venue
- European Radiology
- Published
- 2009-09-02
- Volume
- 20
- Issue
- 3
- Pages
- 734-742
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2157687887
- Cited by
- 497
- References
- 35
- FWCI
- 16.01
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.