CoChat

Publication bias in diagnostic imaging: conference abstracts with positive conclusions are more likely to be published

Open access

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

Objective To evaluate whether imaging diagnostic test accuracy conference abstracts with positive conclusions or titles are more likely to reach full-text publication than those with negative (or neutral) conclusions or titles.Methods Diagnostic accuracy research abstracts were included if they were presented at the 2011 or 2012 Radiological Society of North America conference. Full-text publication status at 5 years post conference abstract submission was determined. Conclusion and title positivity of conference abstracts were extracted, as well as potential confounding factors. The associations of conclusion and title positivity with publication status at 5 years post conference abstract submission were assessed using a multivariable logistic regression model. Conditional odds ratios were calculated to express the strength of associations, adjusting for the confounders.Results In total, 282/400 (71%) of included conference abstracts reached full-text publication. A total of 246 out of 337 (74%) conference abstracts with positive conclusions resulted in full-text publications, compared with 26/48 (54%) with neutral conclusions and 5/15 (33%) with negative conclusions. In multivariable logistic regression, conclusion positivity was significantly associated with full-text publication (odds ratio 3.6; 95% CI 1.9-6.7 for conference abstracts with positive conclusions, compared with those with non-positive conclusions); this did not apply to title positivity (odds ratio 1.2; 95% CI 0.47-3.0).Conclusion Imaging conference abstracts with positive conclusions were more likely to be published as full-text articles. Title positivity was not associated with publication. This preferential publication pattern may lead to an overrepresentation of positive studies in the literature. An overrepresentation of positive studies may contribute to inflated estimates of test accuracy and has the potential to adversely influence patient care.Key points • Imaging diagnostic test accuracy conference abstracts with positive conclusions were more likely to be reported as full-text articles than those with non-positive conclusions. • The majority (75%) of imaging diagnostic test accuracy conference abstracts with positive conclusions were published, compared with only 53% and 33% with neutral and negative conclusions, respectively. • Conclusion positivity remained associated with the full-text publication of conference abstracts when controlling for multiple potential confounding variables.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00330-019-06568-z

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 42

Metadata

Authors
Treanor, L., Frank, R. A., Cherpak, L. A., Dehmoobad Sharifabadi, A., Salameh, J.-P., Hallgrimson, Z., Fabiano, N., McGrath, T. A., Kraaijpoel, N., Yao, J., Korevaar, D. A., Bossuyt, P. M., & McInnes, M. D. F.
Affiliations
  • University of Ottawa (CA)
  • Amsterdam University Medical Centers (NL)
  • Amsterdam Public Health (NL)
Corresponding author
McInnes, Matthew D. F.
Venue
European Radiology
Published
2020-01-17
Volume
30
Issue
5
Pages
2964-2972
ISSN
  • 0938-7994 (ISSN-L)
  • 1432-1084
OpenAlex
W2999252450
Cited by
38
References
39
Citations by year
2026: 1 · 2025: 6 · 2024: 6 · 2023: 8 · 2022: 10 · 2021: 2 · 2020: 3
FWCI
3.49
Type
journal article
Language
en
Open access
Licence
Locations
  • European Radiology (publishedVersion)
  • PubMed (publishedVersion)
  • Pure Amsterdam UMC (submittedVersion, public-domain)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Funders
  • University of Ottawa
  • Mach-Gaensslen Foundation of Canada
Topics
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
  • Social Sciences › Library and Information Sciences › Academic Writing and Publishing
  • Social Sciences › Library and Information Sciences › Academic Publishing and Open Access
Keywords
publication bias, diagnostic accuracy, diagnostic imaging, full-text publications
MeSH terms
Abstracting and Indexing, Data Accuracy, Diagnostic Imaging, Humans, North America, Radiology, Multivariate Analysis, Logistic Models, Publication Bias

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Publication bias in diagnostic imaging: conference abstracts with positive conclusions are more likely to be published. https://app.cochat.ai/papers/10.1007/s00330-019-06568-z
The paper
Treanor, L., Frank, R. A., Cherpak, L. A., Dehmoobad Sharifabadi, A., Salameh, J.-P., Hallgrimson, Z., Fabiano, N., McGrath, T. A., Kraaijpoel, N., Yao, J., Korevaar, D. A., Bossuyt, P. M., & McInnes, M. D. F. (2020). Publication bias in diagnostic imaging: conference abstracts with positive conclusions are more likely to be published. European Radiology. https://doi.org/10.1007/s00330-019-06568-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.