Transistor records of excitable neurons from rat brain

Vassanelli, S., Fromherz, P.·1998·Applied Physics A: Materials Science & Processing

Integrity signals

Registry

Crossref · 10.1007/s003390050695

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The simulated ISFET device has a pH sensitivity of about 50 mV/pH in terms of threshold voltage shift.

    “A sensitivity of about 50mV/pH in terms of threshold voltage shift has been found, in agreement with literature data ([6], [9]).”

Cites

Still being checked.

Cited by

Sorted by citations

Authors
Vassanelli, S., & Fromherz, P.
Affiliations
Max Planck Institute of Biochemistry (DE)
Venue
Applied Physics A: Materials Science & Processing
Published
1998-04-01
Volume
66
Issue
4
Pages
459-463
ISSN
  • 0947-8396 (ISSN-L)
  • 1432-0630
OpenAlex
W1966055252
Cited by
74
References
0
Citations by year
2023: 1 · 2021: 3 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 2 · 2013: 4 · 2012: 6
FWCI
1.19
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Physics A (publishedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
field-effect transistors, excitable neurons, action potential, voltage-gated sodium channels, voltage-gated potassium channels, cultured neurons, oxidized silicon, signal averaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review