Limits to the sensitivity of a low noise compact atomic gravimeter
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of 1.4×10-8g at 1 s. This result relies on the combination of a low phase noise laser system, efficient detection scheme and good shielding from vibrations. In particular, we describe a simple and robust technique of vibration compensation, which is based on correcting the interferometer signal by using the ac acceleration signal measured by a low noise seismometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic interferometry using stimulated Raman transitions
Kasevich, M., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.181 · Cited by 1,377
High-precision gravity measurements using atom interferometry
Peters, A., Chung, K. Y., & Chu, S. (2001) · Metrologia · doi:10.1088/0026-1394/38/1/4 · Cited by 965
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Sensitive absolute-gravity gradiometry using atom interferometry
McGuirk, J. M., Foster, G. T., Fixler, J. B., Snadden, M. J., & Kasevich, M. A. (2002) · Physical Review A · doi:10.1103/physreva.65.033608 · Cited by 586
Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard
Santarelli, G., Laurent, P., Lemonde, P., Clairon, A., Mann, A. G., Chang, S., Luiten, A. N., & Salomon, C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4619 · Cited by 569
Self-citationAtom Interferometer Measurement of the Newtonian Constant of Gravity
Fixler, J. B., Foster, G. T., McGuirk, J. M., & Kasevich, M. A. (2007) · Science · doi:10.1126/science.1135459 · Cited by 554
Optical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer
Riehle, F., Kisters, T., Witte, A., Helmcke, J., & Bordé, C. J. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.177 · Cited by 541
Atomic interferometry with internal state labelling
Bordé, C. J. (1989) · Physics Letters A · doi:10.1016/0375-9601(89)90537-9 · Cited by 535
Rotation sensing with a dual atom-interferometer Sagnac gyroscope
Gustavson, T. L., Landragin, A., & Kasevich, M. A. (2000) · Classical and Quantum Gravity · doi:10.1088/0264-9381/17/12/311 · Cited by 470
Self-citationSix-Axis Inertial Sensor Using Cold-Atom Interferometry
Canuel, B., Leduc, F., Holleville, D., Gauguet, A., Fils, J., Virdis, A., Clairon, A., Dimarcq, N., Bordé, C. J., Landragin, A., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.010402 · Cited by 387
Self-citation
Cited by
Kitching, J., Knappe, S., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 330
The influence of transverse motion within an atomic gravimeter
Louchet-Chauvet, A., Farah, T., Bodart, Q., Clairon, A., Landragin, A., Merlet, S., & Santos, F. P. D. (2011) · New Journal of Physics · doi:10.1088/1367-2630/13/6/065025 · Cited by 263
Self-citationGeophysics From Terrestrial Time‐Variable Gravity Measurements
Van Camp, M., de Viron, O., Watlet, A., Meurers, B., Francis, O., & Caudron, C. (2017) · Reviews of Geophysics · doi:10.1002/2017rg000566 · Cited by 248
Mobile quantum gravity sensor with unprecedented stability
Freier, C., Hauth, M., Schkolnik, V, Leykauf, B., Schilling, M., Wziontek, H., Scherneck, H.-G., Müller, J., & Peters, A. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012050 · Cited by 245
Sensitivity limits of a Raman atom interferometer as a gravity gradiometer
Sorrentino, F., Bodart, Q., Cacciapuoti, L., Lien, Y.-H., Prevedelli, M., Rosi, G., Salvi, L., & Tino, G. M. (2014) · Physical Review A · doi:10.1103/physreva.89.023607 · Cited by 228
Dual matter-wave inertial sensors in weightlessness
Barrett, B., Antoni-Micollier, L., Chichet, L., Battelier, B., Lévèque, T., Landragin, A., & Bouyer, P. (2016) · Nature Communications · doi:10.1038/ncomms13786 · Cited by 212
“Changing the sign of the transfer direction allows the rejection of direction-independent systematics by summing two consecutive, alternated measurements [13, 24].”
BackgroundMethodInfluentialSelf-citationSTE-QUEST—test of the universality of free fall using cold atom interferometry
Aguilera, D. N., Ahlers, H., Battelier, B., Bawamia, A., Bertoldi, A., Bondarescu, R., Bongs, K., Bouyer, P., Braxmaier, C., Cacciapuoti, L., et al. (2014) · Classical and Quantum Gravity · doi:10.1088/0264-9381/31/11/115010 · Cited by 180
“Still, the quadratic Zeeman effect coupled to the small offset field B0 = 1 mG and a magnetic field gradient ∇B induce an acceleration [68, 69].”
Self-citationSimultaneous dual-species matter-wave accelerometer
Bonnin, A., Zahzam, N., Bidel, Y., & Bresson, A. (2013) · Physical Review A · doi:10.1103/physreva.88.043615 · Cited by 174
Marine Absolute Gravity Field Surveys Based on Cold Atomic Gravimeter
Wu, B., Zhang, C., Wang, K., Cheng, B., Zhu, D., Li, R., Wang, X., Lin, Q., Qiao, Z., & Zhou, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3309499 · Cited by 42
“Compared with optical absolute gravimeters, atomic absolute gravimeters [12], [13], [14] offer several advantages, such as a high repetition rate and no mechanical movable parts.”
Background
Metadata
- Authors
- Le Gouët, J., Mehlstäubler, T. E., Kim, J., Merlet, S., Clairon, A., Landragin, A., & Pereira Dos Santos, F.
- Venue
- Applied Physics B
- Published
- 2008-06-27
- Volume
- 92
- Issue
- 2
- Pages
- 133-144
- ISSN
- 0721-7269 (ISSN-L)
- 0946-2171
- 1432-0649
- OpenAlex
- W2032140091
- Cited by
- 294
- References
- 20
- FWCI
- 31.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.