CoChat

Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running

Open access

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index; 4 of the 22 sources its claims cite were checked for support.

Abstract

Pulmonary gas exchange analysis was compared to changes in muscle oxygen saturation as measured by near-infrared spectroscopy. First, ventilatory thresholds determined by common gas exchange analysis and breakpoints in muscle oxygen saturation were assessed for agreement during exercise with increasing intensity. Secondly, the relationship between muscle oxygen saturation as a surrogate for local oxygen extraction and peak oxygen uptake was assessed. In order to lend robustness to future NIRS testing on a broader scale, considering its potential for simple and cost-effective application, the question of a running versus a cycling modality was integrated into the design. Ten participants, of whom five were recreationally trained cyclists and five recreationally trained runners, were tested; each during a cycling test and a running test with increasing intensity to voluntary exhaustion. Muscle oxygen saturation and pulmonary gas exchange measurements were conducted. Bland-Altman analysis showed a moderate degree of agreement between both muscle oxygen saturation breakpoint 1 and muscle oxygen saturation breakpoint 2 and corresponding ventilatory threshold 1 and ventilatory threshold 2, for both cycling and running disciplines; generally speaking, muscle oxygen saturation breakpoints underestimated ventilatory thresholds. Additionally, a strong relationship could be seen between peak oxygen uptake and the minimally attained muscle oxygen saturation during cycling exercise. Muscle oxygen saturation measured using NIRS was determined to be a suitable method to assess ventilatory thresholds by finding breakpoints in muscle oxygen saturation, and muscle oxygen saturation minimum was linked to peak oxygen uptake.

Overview

CoChat Summary

TL;DR

NIRS-derived muscle oxygen saturation breakpoints showed moderate agreement with ventilatory thresholds during incremental cycling and running, generally underestimating VT1/VT2. SmO2min correlated strongly with VO2peak in cycling but weakly in running.

Key findings

  • Bland-Altman showed moderate agreement between SmO2 BP1/BP2 and VT1/VT2 in both cycling and running; BPs generally underestimated VTs. BP1 cycling MB: 15.4 ± 7.4 bpm vs running MB: 1.8 ± 5.6 bpm; BP2 cycling MB: 9.3 ± 7.8 bpm, running MB: 4.2 ± 7.2 bpm.
  • Time-point agreement: VT1 cycle MB: 70.6 ± 64.0 s, run MB: 10.4 ± 49.1 s; VT2 cycle MB: 5.8 ± 59.2 s, run MB: 5.0 ± 28.3 s; approximately one performance step in power/speed.
  • VO2peak correlated with SmO2min at cessation: cycling R² = 0.8512; running R² = 0.266.
  • BP2 inflection pattern varied: cycling positive in 7/10 and negative in 3/10; running positive in 2 and negative in 5; running had three tests with only one clear BP.

Methods

  • Ten analyzed participants (six males, four females; five recreationally trained cyclists, five recreationally trained runners) after four of 14 were removed due to adipose tissue thickness; each completed a cycling and a running incremental test to voluntary exhaustion one week apart, randomized order.
  • Gas exchange was measured breath-by-breath (Oxycon Jaeger); SmO2 was measured with NIRS (Moxy Monitor) on right and left vastus lateralis. Cycling: 60-s increments of 25 W; running: 30-s increments of 0.5 km/h at 7% incline.
  • VT1/VT2 were determined by expert 9-panel CPET; BP1/BP2 by automated segmented regression on SmO2 (four knots, first 60 s excluded). Agreement assessed with Bland-Altman on heart rate; VO2peak–SmO2min relationship with Pearson correlation.

Limitations

  • Stated: ATT is a source of concern and required excluding four participants; ATT differences between female and male groups were large and could confound apparent sex differences; muscle probe site and exercise discipline affect SmO2 measurements; protocol choice affects results; BP determination lacks standardization.
  • Stated: no clear conclusion could be reached on SmO2 time-course patterns by biological sex and ATT, though there was a slight skew toward higher ATT yielding two negative deflection points; one athlete was an outlier with a large cycling-vs-running SmO2min difference.
  • Evident from text: small analyzed sample (n=10) with uneven sex distribution across cyclist/runner groups; some running tests had only one clear BP and some VT2 could not be clearly identified; BP2 could be positive or negative, complicating automated threshold identification.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.2478/hukin-2022-0054

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Two different time courses of SmO2 (o) with increasing performance to voluntary exhaustion. Both charts presented are cycling test results. The dashed vertical lines represent left leg BP1 and BP2, respectively. The red lines represent the linear regression lines that dictate BP1 and BP2. The gray area represents the power time course and the solid black line the heart rate time course.
Figure 1 Two different time courses of SmO2 (o) with increasing performance to voluntary exhaustion. Both charts presented are cycling test results. The dashed vertical lines represent left leg BP1 and BP2, respectively. The red lines represent the linear regression lines that dictate BP1 and BP2. The gray area represents the power time course and the solid black line the heart rate time course.CC BY · PubMed Central
Figure 2 Figure 2 Bland-Altman plots of SmO2 BP and VT for both cycling and running tests. The solid line identifies the mean bias (MB) and dashed lines the upper and lower limits of agreement at ±1.96 SD. The gray shaded area represents the 95% CI for MB. For a few of the tests a clear VT2 could not be identified, as seen in the VT2 Bland-Altman plots; see text for details.
Figure 2 Figure 2 Bland-Altman plots of SmO2 BP and VT for both cycling and running tests. The solid line identifies the mean bias (MB) and dashed lines the upper and lower limits of agreement at ±1.96 SD. The gray shaded area represents the 95% CI for MB. For a few of the tests a clear VT2 could not be identified, as seen in the VT2 Bland-Altman plots; see text for details.CC BY · PubMed Central
Figure 3 Relationship between minimally attained SmO2 value and VO2peak at voluntary exhaustion. The dotted line illustrates the line of the best fit for running (■); R2 = 0.266. The dashed line illustrates the line of the best fit for cycling (▲); R2 = 0.8512.
Figure 3 Relationship between minimally attained SmO2 value and VO2peak at voluntary exhaustion. The dotted line illustrates the line of the best fit for running (■); R2 = 0.266. The dashed line illustrates the line of the best fit for cycling (▲); R2 = 0.8512.CC BY · PubMed Central
Figure 4 Mean and standard deviation of cycling and running test VO2peak and SmO2min for both the cyclists specialised group and the running specialised group..
Figure 4 Mean and standard deviation of cycling and running test VO2peak and SmO2min for both the cyclists specialised group and the running specialised group..CC BY · PubMed Central

Verification

Claims the paper makes

4 Valid · 0 Not valid · 11 Not checked · 24 Own results and interpretations

16 more claims

Create a free account to see all 39 claims and to verify the 1 reference still open.

See all claims — free account
  • It may state two separate claims as one. 8
  • Probably not a substantial claim. 10

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

5 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 33 references

Research works printed but not linked: 1

  1. Kyrolainen H. Komi P. V. & Belli A. 1999 Changes in Muscle Activity Patterns and Kinetics With Increasing Running Speed The Journal of Strength and Conditioning Research 13 4 400 10.1519/1533-4287(1999)013<0400:CIMAPA>2.0.CO;2 · doi:10.1519/1533-4287(1999)013

Cited by

See all 41

Metadata

Authors
Feldmann, A., Ammann, L., Gächter, F., Zibung, M., & Erlacher, D.
Affiliations
University of Bern (CH)
Corresponding author
Feldmann, Andri
Venue
Journal of Human Kinetics
Published
2022-09-08
Volume
83
Pages
87-97
ISSN
  • 1640-5544 (ISSN-L)
  • 1899-7562
OpenAlex
W4294934500
Cited by
41
References
32
Citations by year
2026: 9 · 2025: 17 · 2024: 9 · 2023: 6
FWCI
4.37
Type
journal article
Language
en
Open access
Locations
  • Journal of Human Kinetics (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
  • Bern Open Repository and Information System (University of Bern) (submittedVersion, cc-by)
  • Open Access CRIS of the University of Bern
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
Keywords
muscle oxygen saturation, ventilatory threshold, near-infrared spectroscopy, pulmonary gas exchange, peak oxygen uptake, exercise intensity, cycling, running

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-13, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-13 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running. https://app.cochat.ai/papers/10.2478/hukin-2022-0054
The paper
Feldmann, A., Ammann, L., Gächter, F., Zibung, M., & Erlacher, D. (2022). Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running. Journal of Human Kinetics. https://doi.org/10.2478/hukin-2022-0054

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.