CoChat

Reliability and accuracy of segmental bioelectrical impedance analysis for assessing muscle and fat mass in older Europeans: a comparison with dual-energy X-ray absorptiometry

Mally, Katharina, Trentmann, Jens, Heller, Martin, Dittmar, Manuela · 2011 · European Journal of Applied Physiology

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

Segmental determination of muscle and fat mass (MM, FM) attains growing importance for judging effects of training and malnutrition in older people. This study evaluated the reliability and accuracy of segmental bioelectrical impedance analysis (sBIA) for use in older people. In 72 (40 men, 32 women) healthy elderly (mean age 69.0 ± 4.8 years), the MM and FM of right and left arm (RA, LA), right and left leg (RL, LL), and trunk were determined by sBIA (BC-418-MA, Tanita) and dual-energy X-ray absorptiometry (DXA) as a reference method. The sBIA provided in both sexes reliable values for limb and truncal MM and FM, except for MM of RL in women. The accuracy of sBIA displayed sex-specific bias. For MM, accurate values were noted for men's trunk and women's limbs (except LA). By contrast, MM was significantly underestimated in men's limbs by 6-18% and overestimated in women's LA (13%) and trunk (14%). Estimates of FM were accurate for men's arms as well as women's legs and trunk. However, FM was significantly overestimated in men's legs (34-37%) and trunk (60%), but underestimated in women's arms (27-35%). The proportional deviations of sBIA estimates from DXA values for limbs and trunk were significantly related to the respective MM or FM. The sBIA tends to underestimate MM in men and to overestimate in women. The reverse occurs for FM. The actual equations of the Tanita device may not completely represent the European older population and should be partly revised.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00421-010-1795-x

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 27 references

Research works printed but not linked: 1

  1. Cha K, Shin S, Shon C, Choi S, Wilmore DW (1997) Evaluation of segmental bioelectrical impedance analysis (SBIA) for measuring muscle distribution. J ICHPER SD-Asia 1:11–14

Cited by

See all 59

Metadata

Authors
Mally, K., Trentmann, J., Heller, M., & Dittmar, M.
Affiliations
  • Christian-Albrechts-Universität zu Kiel (DE)
  • University Hospital Schleswig-Holstein (DE)
Corresponding author
Dittmar, Manuela
Venue
European Journal of Applied Physiology
Published
2011-01-14
Volume
111
Issue
8
Pages
1879-1887
ISSN
  • 0020-9376 (ISSN-L)
  • 1439-6319
  • 1439-6327
OpenAlex
W2005238167
Cited by
49
References
27
Citations by year
2026: 2 · 2025: 3 · 2024: 2 · 2023: 1 · 2022: 2 · 2020: 5 · 2019: 2 · 2018: 5 · 2017: 5 · 2016: 3 · 2015: 3 · 2014: 4 · 2013: 8 · 2012: 2
FWCI
3.49
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • European Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
Bundesamt für Strahlenschutz
Topics
  • Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Physiology (medical) › Nutrition and Health in Aging
  • Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
Keywords
segmental bioelectrical impedance analysis, muscle mass, fat mass, older adults, dual-energy X-ray absorptiometry, measurement reliability, measurement accuracy, sex differences, trunk fat mass, reference equations
MeSH terms
Adipose Tissue, Age Factors, Aged, Aged, 80 and over, Anthropometry, Body Composition, Europe, Female, Humans, Male, Middle Aged, Organ Size, Reproducibility of Results, Absorptiometry, Photon, Electric Impedance, Muscle, Skeletal, White People

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability and accuracy of segmental bioelectrical impedance analysis for assessing muscle and fat mass in older Europeans: a comparison with dual-energy X-ray absorptiometry. https://app.cochat.ai/papers/10.1007/s00421-010-1795-x
The paper
Mally, K., Trentmann, J., Heller, M., & Dittmar, M. (2011). Reliability and accuracy of segmental bioelectrical impedance analysis for assessing muscle and fat mass in older Europeans: a comparison with dual-energy X-ray absorptiometry. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-010-1795-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.