Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We evaluate the accuracy of whole body muscle mass (WBMM) and appendicular skeletal muscle mass (ASMM) assessed by bioelectrical impedance analysis (BIA) using an InBody770 machine (InBody, Seoul, Korea) referenced to dual-energy X-ray absorptiometry (DXA) in 507 people (mean age 63.7 ± 10.8 years, body mass index (BMI) 25.2 ± 3.5 kg/m2). Mean WBMMs measured by BIA and DXA were 49.3 ± 6.6 kg and 46.8 ± 6.5 kg in men and 36.1 ± 4.7 kg and 34.0 ± 4.8 kg in women, respectively. The respective effect sizes and 95% confidence intervals (CIs) for the difference were 2.49 (2.22–2.76) for men, and 2.12 (1.91–2.33) for women. Mean ASMMs measured by BIA and DXA were 22.1 ± 3.3 kg and 19.9 ± 3.2 kg in men, and 15.3 ± 2.5 kg and 13.5 ± 2.2 kg in women, respectively. The respective effect sizes and 95% CIs for the difference were 2.26 (2.10–2.41) for men and 1.75 (1.65–1.87) for women. The BIA clearly overestimated WBMM by 2.28 kg and ASMM by 1.97 kg compared with DXA. Using BMI, gender, and fat percentage, we derive equations that improved the residuals to <2 kg between methods from 38.29% to 85.91% for WBMM and 52.78% to 97.02% for ASMM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sarcopenia in Asia: Consensus Report of the Asian Working Group for Sarcopenia
Chen, L.-K., Liu, L.-K., Woo, J., Assantachai, P., Auyeung, T.-W., Bahyah, K. S., Chou, M.-Y., Chen, L.-Y., Hsu, P.-S., Krairit, O., et al. (2014) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2013.11.025 · Cited by 4,051
Epidemiology of Sarcopenia among the Elderly in New Mexico
Baumgartner, R. N., Koehler, K. M., Gallagher, D., Romero, L., Heymsfield, S. B., Ross, R. R., Garry, P. J., & Lindeman, R. D. (1998) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009520 · Cited by 4,004
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 1×
“Among them, BIA has drawn attention because it is easily applicable, imposes no burden on subjects, involves easy to move and relatively cheap equipment, and most importantly, poses no radiation hazard [18,19].”
Janssen, I., Heymsfield, S. B., & Ross, R. (2002) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2002.50216.x · Cited by 3,139
Studenski, S. A., Peters, K. W., Alley, D. E., Cawthon, P. M., McLean, R. R., Harris, T. B., Ferrucci, L., Guralnik, J. M., Fragala, M. S., Kenny, A. M., et al. (2014) · The Journals of Gerontology: Series A · doi:10.1093/gerona/glu010 · Cited by 2,545 · cited 1×
“We derived specific equations for ASMM as well as WBMM, which are critical in the diagnosis of sarcopenia [40,41].”
Estimation of skeletal muscle mass by bioelectrical impedance analysis
Janssen, I., Heymsfield, S. B., Baumgartner, R. N., & Ross, R. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.2.465 · Cited by 1,482 · cited 1×
“Thus, BIA is widely used not only in specialized facilities, but also in fitness and health checkup centers [20].”
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370 · cited 1×
“Resistance was measured at four surface tactile electrodes placed on the dorsal surface of the hand and foot by the BIA generator; the formula V = $χ height2/resistance was used to derive muscle mass mathematically [30].”
Pitfalls in the measurement of muscle mass: A need for a reference standard
Buckinx, F., Landi, F., Cesari, M., Fielding, R. A., Visser, M., Engelke, K., Maggi, S., Dennison, E., Al‐Daghri, N. M., Allepaerts, S., et al. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12268 · Cited by 765
(1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.524s · Cited by 549
Sergi, G., De Rui, M., Veronese, N., Bolzetta, F., Berton, L., Carraro, S., Bano, G., Coin, A., Manzato, E., & Perissinotto, E. (2015) · Clinical Nutrition · doi:10.1016/j.clnu.2014.07.010 · Cited by 467 · cited 4×
“However, most studies were conducted with subjects of European origin [16,17].”
Influential
Cited by
Nuzzo, J. L. (2023) · Journal of Strength & Conditioning Research · doi:10.1519/jsc.0000000000004329 · Cited by 304
Cheng, K. Y., Chow, S. K., Hung, V. W., Wong, C. H., Wong, R. M., Tsang, C. S., Kwok, T., & Cheung, W. (2021) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1002/jcsm.12825 · Cited by 154
“1 kg compared with DXA found in their study with Korean population.(23) Other considerations should also be taken into account when screening with the BIA on specific patient groups like chronic heart disease, kidney diseases, or cancer who are taking chemotherapy or other treatments that would cause severe dehydratio…”
ResultAntonio, J., Kenyon, M., Ellerbroek, A., Carson, C., Burgess, V., Tyler-Palmer, D., Mike, J., Roberts, J., Angeli, G., & Peacock, C. (2019) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk4020023 · Cited by 106
Son, J. W., Han, B., Bennett, J. P., Heymsfield, S., & Lim, S. (2025) · Obesity Reviews · doi:10.1111/obr.13844 · Cited by 74
Self-citationPark, J. H., Kim, J. Y., Choi, J. H., Park, H. S., Shin, H.-Y., Lee, J. M., Kim, J.-W., Ko, H.-J., Chon, S., Kim, B. K., et al. (2021) · International Journal of Obesity · doi:10.1038/s41366-021-00739-z · Cited by 48
Self-citation
Metadata
- Authors
- Lee, S. Y., Ahn, S., Kim, Y. J., Ji, M. J., Kim, K. M., Choi, S. H., Jang, H. C., & Lim, S.
- Venue
- Nutrients
- Publisher
- MDPI AG
- Published
- 2018-06-07
- Volume
- 10
- Issue
- 6
- Pages
- 738
- ISSN
- 2072-6643 (ISSN-L)
- OpenAlex
- W2806093627
- Cited by
- 175
- References
- 21
- FWCI
- 10.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass. https://app.cochat.ai/papers/10.3390/nu10060738
- The paper
- Lee, S. Y., Ahn, S., Kim, Y. J., Ji, M. J., Kim, K. M., Choi, S. H., Jang, H. C., & Lim, S. (2018). Comparison between Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analyses for Accuracy in Measuring Whole Body Muscle Mass and Appendicular Skeletal Muscle Mass. Nutrients. https://doi.org/10.3390/nu10060738
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.