Exercise intensity effects on total sweat electrolyte losses and regional vs. whole-body sweat [Na+], [Cl−], and [K+]
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
To quantify total sweat electrolyte losses at two relative exercise intensities and determine the effect of workload on the relation between regional (REG) and whole body (WB) sweat electrolyte concentrations. Eleven recreational athletes (7 men, 4 women; 71.5 ± 8.4 kg) completed two randomized trials cycling (30 °C, 44% rh) for 90 min at 45% (LOW) and 65% (MOD) of V O 2max in a plastic isolation chamber to determine WB sweat [Na + ] and [Cl − ] using the washdown technique. REG sweat [Na + ] and [Cl − ] were measured at 11 REG sites using absorbent patches. Total sweat electrolyte losses were the product of WB sweat loss (WBSL) and WB sweat electrolyte concentrations. WBSL (0.86 ± 0.15 vs. 1.27 ± 0.24 L), WB sweat [Na + ] (32.6 ± 14.3 vs. 52.7 ± 14.6 mmol/L), WB sweat [Cl − ] (29.8 ± 13.6 vs. 52.5 ± 15.6 mmol/L), total sweat Na + loss (659 ± 340 vs. 1565 ± 590 mg), and total sweat Cl − loss (931 ± 494 vs. 2378 ± 853 mg) increased significantly ( p < 0.05) from LOW to MOD. REG sweat [Na + ] and [Cl − ] increased from LOW to MOD at all sites except thigh and calf. Intensity had a significant effect on the regression model predicting WB from REG at the ventral wrist, lower back, thigh, and calf for sweat [Na + ] and [Cl − ]. Total sweat Na + and Cl − losses increased by ~ 150% with increased exercise intensity. Regression equations can be used to predict WB sweat [Na + ] and [Cl − ] from some REG sites (e.g., dorsal forearm) irrespective of intensity (between 45 and 65% V O 2max ), but other sites (especially ventral wrist, lower back, thigh, and calf) require separate prediction equations accounting for workload.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“sweat [Na+] and [Cl−] measured from the forehead, torso, and upper arms are often greater than whole body measurements. However, sweat [Na+] and [Cl−] from other sites such as the foot, calf, and thigh are similar to that of the whole body (Baker et al. 2019, 2009, 2018b; Patterson et al. 2000).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Baker et al. 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Power Analysis for the Behavioral Sciences
Muller, K. (1989) · Technometrics · doi:10.1080/00401706.1989.10488618 · Cited by 99,167
Statistical power analysis for the behavioral sciences
(1990) · Computers, Environment and Urban Systems · doi:10.1016/0198-9715(90)90050-4 · Cited by 65,269
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580
(2014) · Medical Entomology and Zoology · Cited by 9,400
A formula to estimate the approximate surface area if height and weight be known. 1916.
Bois, D. D., & Bois, E. F. D. (1989) · PubMed · Cited by 5,706
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Du BOIS, D. (1916) · Archives of Internal Medicine · doi:10.1001/archinte.1916.00080130010002 · Cited by 4,342
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Exercise and Fluid Replacement
(2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802ca597 · Cited by 1,497
Nutrition and Athletic Performance
(2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000852 · Cited by 1,305
Cited by
Physiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
Self-citationSkin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
“1989), very few recent reviews have provided an update on mechanisms underlying sweat composition in the context of sweat as a potential biomarker of human health (Baker 2019).”
BackgroundMethodResultInfluentialSelf-citationMiao, D., Cheng, N., Wang, X., Yu, J., & Ding, B. (2022) · Nano Letters · doi:10.1021/acs.nanolett.1c03801 · Cited by 256
Ardalan, S., Hosseinifard, M., Vosough, M., & Golmohammadi, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112450 · Cited by 195
State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics
Ghaffari, R., Yang, D. S., Kim, J., Mansour, A., Wright, J. A., Model, J. B., Wright, D. E., Rogers, J. A., & Ray, T. R. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01133 · Cited by 178
Bioaccessibility and Bioavailability of Minerals in Relation to a Healthy Gut Microbiome
Bielik, V., & Kolisek, M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22136803 · Cited by 172
“The concentration of sodium (Na), the main component of sweat, and the daily loss of Na because of athletic training vary according to sport intensity [14],”
BackgroundPediatric Thermoregulation: Considerations in the Face of Global Climate Change
Smith, C. J. (2019) · Nutrients · doi:10.3390/nu11092010 · Cited by 153
The role of sampling in wearable sweat sensors
Liu, C., Xu, T., Wang, D., & Zhang, X. (2020) · Talanta · doi:10.1016/j.talanta.2020.120801 · Cited by 151
Reeder, J. T., Xue, Y., Franklin, D., Deng, Y., Choi, J., Prado, O., Kim, R., Liu, C. Y., Hanson, J., Ciraldo, J. P., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13431-8 · Cited by 129
Zhang, Y., Chen, Y., Huang, J., Liu, Y., Peng, J., Chen, S., Song, K., Ouyang, X., Cheng, H., & Wang, X. (2020) · Lab on a Chip · doi:10.1039/d0lc00400f · Cited by 118
Komkova, M. A., Eliseev, A. A., Poyarkov, A. A., Daboss, E. V., Evdokimov, P. V., Eliseev, A. A., & Karyakin, A. A. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.113970 · Cited by 116
Li, F., Wang, S., Wang, Z., Jiang, K., Zhao, X., Shao, L., & Pan, Y. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202210769 · Cited by 97
Clark, K. M., & Ray, T. R. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01512 · Cited by 93
Klous, L., de Ruiter, C. J., Scherrer, S., Gerrett, N., & Daanen, H. A. M. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04562-8 · Cited by 86
Nanoengineered Textiles for Outdoor Personal Cooling and Drying
Miao, D., Wang, X., Yu, J., & Ding, B. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202209029 · Cited by 75
Worth your sweat: wearable microfluidic flow rate sensors for meaningful sweat analytics
Ursem, R. F. R., Steijlen, A. S. M., Parrilla, M., Bastemeijer, J., Bossche, A., & Wael, K. D. (2025) · Lab on a Chip · doi:10.1039/d4lc00927d · Cited by 68
Flexible epidermal wearable sensor for Athlete's sweat biomarkers monitoring
Cai, J., Cao, M., Bai, J., Sun, M., Ma, C., Emran, M. Y., Kotb, A., Bo, X., & Zhou, M. (2024) · Talanta · doi:10.1016/j.talanta.2024.126986 · Cited by 63
Effect of exercise training on the renin–angiotensin–aldosterone system: a meta–analysis
Baffour-Awuah, B., Man, M., Goessler, K. F., Cornelissen, V., Dieberg, G., Smart, N. A., & Pearson, M. J. (2023) · Journal of Human Hypertension · doi:10.1038/s41371-023-00872-4 · Cited by 62
Baker, L. B., Seib, M. S., Barnes, K. A., Brown, S. D., King, M. A., Chavez, P. J. D. D., Qu, S., Archer, J., Wolfe, A. S., Stofan, J. R., et al. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200249 · Cited by 61
Self-citationPérez-Castillo, Í. M., Williams, J. A. S., Chicharro, J. L., Mihic, N., Rueda, R., Bouzamondo, H., & Horswill, C. A. (2023) · Nutrients · doi:10.3390/nu16010017 · Cited by 58
Shajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55
Saengsrichan, A., Saikate, C., Silasana, P., Khemthong, P., Wanmolee, W., Phanthasri, J., Youngjan, S., Posoknistakul, P., Ratchahat, S., Laosiripojana, N., et al. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23095001 · Cited by 53
Wang, S., Liu, M., Shi, Y., Yang, X., Li, L., Lu, Q., Zheng, H., Feng, S., Bai, Y., & Zhang, T. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132290 · Cited by 49
Wearable sweat-sensing patches for non-invasive and continuous health tracking
Shinde, S., Kim, K. H., Park, S. Y., Kim, J. H., Kim, J., Joe, D. J., & Lee, H. E. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100265 · Cited by 49
Rollo, I., Randell, R. K., Baker, L. B., Yanguas, J., Leal, D. M., Lizarraga, A., Mesalles, J., Jeukendrup, A. E., James, L. J., & Carter, J. M. (2021) · Nutrients · doi:10.3390/nu13020401 · Cited by 46
Self-citationWireless and battery-free wearable biosensing of riboflavin in sweat for precision nutrition
Shi, Z., Deng, P., Zhou, L.-A., Jin, M., Fang, F., Chen, T., Liu, G., Wen, H., An, Z., Liang, H., et al. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116136 · Cited by 43
Li, K., Li, H., Xue, Y., Yang, H., Zhang, C., & Xu, Z. (2023) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2023.08.044 · Cited by 43
Baker, L. B., Chavez, P. J. D. D., Nuccio, R. P., Brown, S. D., King, M. A., Sopeña, B. C., & Barnes, K. A. (2022) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00391.2022 · Cited by 42
Self-citationOptical sensors for transdermal biomarker detection: A review
Amjad, A., & Xian, X. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116844 · Cited by 41
Grossmann, F., Flueck, J. L., Perret, C., MEEUSEN, R. R., & Roelands, B. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.636997 · Cited by 40
Cinca-Morros, S., García-Rey, S., Álvarez‐Herms, J., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342988 · Cited by 39
Wang, S., Lafaye, C., Saubade, M., Besson, C., Margarit, J. M., Grémeaux, V., & Liu, S. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3186150 · Cited by 37
Serag, A., Shakkour, Z., Halboup, A. M., Kobeissy, F. H., & Farag, M. A. (2021) · Journal of Proteomics · doi:10.1016/j.jprot.2021.104310 · Cited by 34
McCubbin, A. J., Lopez, M. B., Cox, G. R., Caldwell Odgers, J. N., & Costa, R. J. S. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04199-2 · Cited by 30
Pradas, F., García-Giménez, A., Toro-Román, V., Sánchez-Alcaraz, B. J., Ochiana, N., & Castellar, C. (2020) · Sustainability · doi:10.3390/su12208633 · Cited by 28
Li, H., Early, K. S., Zhang, G., Ma, P., & Wang, H. (2024) · Nutrients · doi:10.3390/nu16091341 · Cited by 28
Sweat rate and sweat composition following active or passive heat re-acclimation: A pilot study
Klous, L., de Ruiter, C. J., Alkemade, P., Daanen, H. A. M., & Gerrett, N. (2020) · Temperature · doi:10.1080/23328940.2020.1826287 · Cited by 26
Adaptively resettable microfluidic patch for sweat rate and electrolytes detection
Liu, M., Liu, S., Zhang, T., Zhou, D., Li, L., Gao, Q., Liu, Y., Ge, C., Wang, Y., Wang, Y., et al. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116299 · Cited by 25
Fluid Balance and Carbohydrate Intake of Elite Female Soccer Players during Training and Competition
Tarnowski, C. A., Rollo, I., Carter, J. M., Lizarraga-Dallo, M. A., Oliva, M. P., Clifford, T., James, L. J., & Randell, R. K. (2022) · Nutrients · doi:10.3390/nu14153188 · Cited by 24
Baker, L. B., Nuccio, R. P., Reimel, A. J., Brown, S. D., Ungaro, C. T., De Chavez, P. J. D., & Barnes, K. A. (2020) · Physiological Reports · doi:10.14814/phy2.14524 · Cited by 22
Self-citationSweat induction using Pilocarpine microneedle patches for sweat testing in healthy adults
Chen, J. Y., Li, S., Silva, G. L., Chandler, J. D., Prausnitz, M. R., & Guglani, L. (2023) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2023.04.014 · Cited by 19
Yang, M., Sun, N., Lai, X., Zhao, X., & Zhou, W. (2023) · Biosensors · doi:10.3390/bios14010017 · Cited by 19
Presta, V., Ambrosini, L., Carubbi, C., Masselli, E., Mirandola, P., Arcari, M. L., Gobbi, G., & Vitale, M. (2021) · Water · doi:10.3390/w13020166 · Cited by 18
Keefe, M. S., Benjamin, C. L., Casa, D. J., & Sekiguchi, Y. (2024) · Applied Sciences · doi:10.3390/app142210103 · Cited by 18
A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate
Wang, H., Xu, K., Xu, H., Huang, A., Fang, Z., Zhang, Y., Wang, Z., Lu, K., Wan, F., Bai, Z., et al. (2022) · Micromachines · doi:10.3390/mi13030414 · Cited by 17
Baker, L. B., King, M. A., Keyes, D. M., Brown, S. D., Engel, M. D., Seib, M. S., Aranyosi, A. J., & Ghaffari, R. (2022) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2022-0017 · Cited by 17
Self-citationSkin-specific mechanisms of body fluid regulation in hypertension
Chen, J. Y., Chew, K. S., Mary, S., Boder, P., Bagordo, D., Rossi, G. P., Touyz, R. M., Delles, C., & Rossitto, G. (2023) · Clinical Science · doi:10.1042/cs20220609 · Cited by 17
Post-exercise rehydration: Comparing the efficacy of three commercial oral rehydration solutions
Peden, D. L., Funnell, M. P., Reynolds, K. M., Kenefick, R. W., Cheuvront, S. N., Mears, S. A., & James, L. J. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1158167 · Cited by 16
Yang, D. S., Zhou, M., Li, S., Cho, S., Wu, Y., Sekine, Y., Kanatzidis, E. E., Lv, Z., Yamagishi, K., Kim, J., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202509169 · Cited by 16
The effect of sweat sample storage condition on sweat content
Klous, L., Folkerts, M. A., Daanen, H. A. M., & Gerrett, N. (2021) · Temperature · doi:10.1080/23328940.2020.1867294 · Cited by 16
Sweat evaporation in humans: A molecular and thermodynamic perspective
Ashworth, E. T. (2025) · Experimental Physiology · doi:10.1113/ep093011 · Cited by 15
Wearable Sensing for Clinical Physiology Monitoring: Emerging Paradigms
Cherian, J., Mascia, G., Kairamkonda, D. D., Fisher, A., McGinnis, R. S., & Ray, T. R. (2025) · Physiology · doi:10.1152/physiol.00039.2024 · Cited by 15
Wearable sweat chloride sensors: materials, fabrication and their applications
Patel, V., Mardolkar, A., Shelar, A., Tiwari, R., & Srivastava, R. (2024) · Analytical Methods · doi:10.1039/d3ay01979a · Cited by 14
Advances and Challenges in Wearable Sensors for Health Monitoring
Brazaca, L. C., Lozano, A. M., Mayol, B., Scheidt, D. T., Fazio, D. D., Kim, E., Maroli, G., Rosati, G., Ates, H. C., Wang, H., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c04520 · Cited by 13
Fundamental Study of a Wristwatch Sweat Lactic Acid Monitor
Konno, S., & Kudo, H. (2024) · Biosensors · doi:10.3390/bios14040187 · Cited by 12
Sabou, V. R., Rush, C., Mason, L., Dupont, G., & Louis, J. B. (2020) · Science and Medicine in Football · doi:10.1080/24733938.2020.1761558 · Cited by 12
Jiang, Y., Xie, Y., Liang, H., Zhang, H., Goto, T., & Niu, J. (2024) · Sustainable Cities and Society · doi:10.1016/j.scs.2024.106020 · Cited by 11
Yang, H., Ding, H., Wei, W., Li, X.-F., Duan, X., Zhuang, C., Liu, W., Chen, S., & Wang, X. (2024) · Lab on a Chip · doi:10.1039/d3lc00791j · Cited by 10
Molecular biomarkers for assessing the heat-adapted phenotype: a narrative scoping review
Corbett, J., Young, J. S., Tipton, M., Costello, J. T., Williams, T. B., Walker, E. F., Lee, B., & Stevens, C. E. (2023) · The Journal of Physiological Sciences · doi:10.1186/s12576-023-00882-4 · Cited by 10
Mild dehydration does not alter acute changes in sweat electrolyte concentrations during exercise
Baker, L. B., Ozga, M., Merritt, J. R., Alfred, S., Chavez, P. J. D. D., & Hinkley, J. M. (2024) · Physiological Reports · doi:10.14814/phy2.16174 · Cited by 10
Self-citationMaking Sweat Measurable: Induction, Sampling, and Refreshment in Wearable Biofluid Sensing
Shin, S., & Gao, W. F. (2026) · Advanced Science · doi:10.1002/advs.75684 · Cited by 10
Béliveau, J., Perreault-Briere, M., Jeker, D., Deshayes, T. A., Suárez, A. D., Baker, L. B., & Goulet, E. D. B. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04350-4 · Cited by 10
Self-citationWang, H., Martone, M., Owens, M. E., Lemoine, N. P., Marucci, J., Calvert, D. D., Mullenix, S., Church, T. S., Rood, J., Harrell, B., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-81473-4 · Cited by 10
Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports
Xuan, X., Rojas, D., Lozano, I., Cuartero, M., & Crespo, G. A. (2024) · Sensors · doi:10.3390/s24227243 · Cited by 9
Sodium Intake for Athletes Before, During and After Exercise: Review and Recommendations
McCubbin, A. J. (2025) · Performance Nutrition · doi:10.1186/s44410-025-00011-9 · Cited by 8
Montorsi, M., Vezzoli, A., Sposta, F. M., Gussoni, M., Brizzolari, A., Bosco, G., Dellanoce, C., Barassi, A., Picconi, B., Ranuncoli, C., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14072532 · Cited by 8
Liang, Z., Liang, Y., Zhang, C., Zhao, X., & Qiu, J. (2024) · Nutrients · doi:10.3390/nu16223799 · Cited by 8
Wang, H., Early, K. S., Theall, B. M., Lowe, A. C., Lemoine, N. P., Marucci, J., Mullenix, S., & Johannsen, N. M. (2020) · Medicina · doi:10.3390/medicina56100502 · Cited by 8
Song, G., Yan, Y., Zhao, H., Chen, J., Deng, Y., Zhu, W., Sun, L., & Ma, G. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275685 · Cited by 8
Chen, K., Huang, Y., Zeng, Y., Li, X., Li, X., Zhu, H., Li, Y., Liu, C., Reinfelder, J. R., Huang, W., et al. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.139100 · Cited by 8
Eslami, Z., Roshandel, G., & Mirghani, S. J. (2025) · Chonnam Medical Journal · doi:10.4068/cmj.2025.61.1.9 · Cited by 7
Role of Basal Hormones on Sweat Rate and Sweat Na+ Loss in Elite Women Soccer Players
Castro‐Sepúlveda, M., Cancino, J., Jannas-Vela, S., Jesam, F., Lobos, C., Coso, J. D., & Zbinden‐Foncea, H. (2020) · International Journal of Sports Medicine · doi:10.1055/a-1165-2072 · Cited by 7
Szymanski, M., Miller, K. C., O'Connor, P., Hildebrandt, L., & Umberger, L. (2020) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003605 · Cited by 7
Dyshko, K., Nicodemus, M. P., Otterstetter, R., Ghadimi, H., Daniels, S., Fulmer, M., Cheney, Z., Ellis, R., Stege, V., & Monty, C. N. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05364-4 · Cited by 7
Keyes, D. M., Brown, S. D., King, M. A., Engel, M. D., Ciciora‐Gold, M., Chavez, P. J. D. D., & Baker, L. B. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04989-1 · Cited by 6
Self-citationLi, D., Xu, C., Ni, Z., Huang, J., & Guo, Z. (2024) · Langmuir · doi:10.1021/acs.langmuir.4c00145 · Cited by 5
Biomarkers in wearables, ingestible, and implantable sensors for health monitoring
Ghosh, G., & Sharma, R. (2025) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2025.05.015 · Cited by 5
Liu, M., Zhang, T., Shen, H., Liu, Y., Liu, S., Ge, C., Zhou, D., Wang, Y., Wang, Y., Wen, F., et al. (2026) · InfoMat · doi:10.1002/inf2.70110 · Cited by 5
Lipman, G. S., Hew‐Butler, T., Phillips, C. T., Krabak, B. J., & Burns, P. (2021) · Sports Medicine - Open · doi:10.1186/s40798-021-00302-0 · Cited by 5
Customizing individual heat mitigation strategies to optimize performance in elite athletes
Sekiguchi, Y., Adams, W. M., Hosokawa, Y., Benjamin, C. L., Stearns, R. L., Huggins, R. A., & Casa, D. J. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1380645 · Cited by 5
A new human metabolic rate sensing model optimization and wearable sensor realization
Zhang, P., Liao, D., Yu, H., & Qiu, H. (2024) · Energy · doi:10.1016/j.energy.2024.132519 · Cited by 5
Liu, Y., Chen, S., Shi, L., Yang, S., Zhang, J., Liu, C., Cheng, J., Shi, J., Shen, C., Gu, D., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202516396 · Cited by 4
From lab to field: progress and prospect of sweat sensing technology in sports monitoring
Gao, N., Deng, X., Lei, Y., Jiang, P., & Wu, Y. (2026) · Microchimica Acta · doi:10.1007/s00604-026-07835-9 · Cited by 3
Microneedle-based electrochemical sensors for health monitoring
Parrilla, M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13881-2.00020-5 · Cited by 3
Reliability and validity of portable sweat sodium analyzers during exercise in the heat
Zhao, X., McKenna, Z., Wierick, S. C., Perez, R. I., Sellner, R. S., Allen, B., & McDermott, B. P. (2026) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2025-0482 · Cited by 2
Perspectives on enhancing human performance in the heat: Is the solution to simply “just add water”?
Millard-Stafford, M. L., Brown, M. B., & Wittbrodt, M. T. (2024) · Sports Medicine and Health Science · doi:10.1016/j.smhs.2024.12.001 · Cited by 2
The effect of short and continuous absorbent patch application on local skin temperature underneath
Klous, L., Folkerts, M. A., Daanen, H. A. M., & Gerrett, N. (2021) · Physiological Measurement · doi:10.1088/1361-6579/abf364 · Cited by 2
Ma, P., Early, K. S., Li, H., Zhang, G., & Wang, H. (2025) · Scientific Reports · doi:10.1038/s41598-025-27715-1 · Cited by 2
Górniak, A., Gizińska, N., Kubas, A., Widawski, M., Sobczyk, A., Lewandowska, P., Rusiecka, A., Zaremba, A., & Cichur, F. (2025) · Medical Science · doi:10.54905/disssi.v29i161.e122ms3636 · Cited by 2
Fluid Intake and Hydration Responses to Mass Participation Gravel Cycling
Schuerger, C., Raik, B., Salmon, F., Foote, K., Madlambayan, A., Vega, M., Handler, G., & Schubert, M. M. (2024) · International journal of exercise science · doi:10.70252/iwvs1647 · Cited by 2
Goods, P. S. R., Wall, B. A., Galna, B., McKay, A. K. A., Jennings, D. H., Peeling, P., & Watson, G. (2024) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2023-0159 · Cited by 1
A Wearable Graphene-Based Sweat Sensor for Real-Time Health Monitoring
Ballam, L. R., Bidsorkhi, H. C., D’Aloia, A. G., & Sarto, M. S. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3606010 · Cited by 1
Thiyagarajan, N., Wade, T., Peringath, A. R., Zhang, D., & Kar‐Narayan, S. (2025) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/s43578-025-01738-w · Cited by 1
COMPUTED TOMOGRAPHY MEDICAL IMAGE ANALYSIS OF BASKETBALL PLAYERS’ BONE GEOMETRY
Liu, B., & Liu, N. (2021) · Revista Brasileira de Medicina do Esporte · doi:10.1590/1517-8692202127042021_0100 · Cited by 1
Wearable Metabolic Sensing for Thermal Comfort Control in Smart and Energy-Efficient Buildings
Zhang, P., & Qiu, H. (2026) · Smart City Symposium Prague (SCSP) · doi:10.1109/scsp69985.2026.11548627 · Cited by 1
Raccoon-paw-inspired porous hydrogel electronic skin for self-powered fused perception
Wen, S., Li, N., Liu, K., Niu, Y., Yang, X., Yao, Y., Gao, Z., Cui, X., Cao, S., Li, Z., et al. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119180 · Cited by 1
Wang, H. (2020) · Louisiana State University · doi:10.31390/gradschool_dissertations.5263
Hydration and Fluid Needs during Physical Activity
Casa, D. J., & Kavouras, S. A. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-3748-1
Béliveau, J. (2020) · Knowledge UdeS (Institutional Deposit of the University of Sherbrooke)
Metadata
- Authors
- Baker, L. B., De Chavez, P. J. D., Ungaro, C. T., Sopeña, B. C., Nuccio, R. P., Reimel, A. J., & Barnes, K. A.
- Venue
- European Journal of Applied Physiology
- Published
- 2018-12-06
- Volume
- 119
- Issue
- 2
- Pages
- 361-375
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2905128970
- Cited by
- 110
- References
- 62
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.