Exercise intensity effects on total sweat electrolyte losses and regional vs. whole-body sweat [Na+], [Cl−], and [K+]
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
To quantify total sweat electrolyte losses at two relative exercise intensities and determine the effect of workload on the relation between regional (REG) and whole body (WB) sweat electrolyte concentrations. Eleven recreational athletes (7 men, 4 women; 71.5 ± 8.4 kg) completed two randomized trials cycling (30 °C, 44% rh) for 90 min at 45% (LOW) and 65% (MOD) of V O 2max in a plastic isolation chamber to determine WB sweat [Na + ] and [Cl − ] using the washdown technique. REG sweat [Na + ] and [Cl − ] were measured at 11 REG sites using absorbent patches. Total sweat electrolyte losses were the product of WB sweat loss (WBSL) and WB sweat electrolyte concentrations. WBSL (0.86 ± 0.15 vs. 1.27 ± 0.24 L), WB sweat [Na + ] (32.6 ± 14.3 vs. 52.7 ± 14.6 mmol/L), WB sweat [Cl − ] (29.8 ± 13.6 vs. 52.5 ± 15.6 mmol/L), total sweat Na + loss (659 ± 340 vs. 1565 ± 590 mg), and total sweat Cl − loss (931 ± 494 vs. 2378 ± 853 mg) increased significantly ( p < 0.05) from LOW to MOD. REG sweat [Na + ] and [Cl − ] increased from LOW to MOD at all sites except thigh and calf. Intensity had a significant effect on the regression model predicting WB from REG at the ventral wrist, lower back, thigh, and calf for sweat [Na + ] and [Cl − ]. Total sweat Na + and Cl − losses increased by ~ 150% with increased exercise intensity. Regression equations can be used to predict WB sweat [Na + ] and [Cl − ] from some REG sites (e.g., dorsal forearm) irrespective of intensity (between 45 and 65% V O 2max ), but other sites (especially ventral wrist, lower back, thigh, and calf) require separate prediction equations accounting for workload.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“sweat [Na+] and [Cl−] measured from the forehead, torso, and upper arms are often greater than whole body measurements. However, sweat [Na+] and [Cl−] from other sites such as the foot, calf, and thigh are similar to that of the whole body (Baker et al. 2019, 2009, 2018b; Patterson et al. 2000).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Baker et al. 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Power Analysis for the Behavioral Sciences
Muller, K. (1989) · Technometrics · doi:10.1080/00401706.1989.10488618 · Cited by 99,167
Statistical power analysis for the behavioral sciences
(1990) · Computers, Environment and Urban Systems · doi:10.1016/0198-9715(90)90050-4 · Cited by 65,269
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580
(2014) · Medical Entomology and Zoology · Cited by 9,400
A formula to estimate the approximate surface area if height and weight be known. 1916.
Bois, D. D., & Bois, E. F. D. (1989) · PubMed · Cited by 5,706
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Du BOIS, D. (1916) · Archives of Internal Medicine · doi:10.1001/archinte.1916.00080130010002 · Cited by 4,342
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Exercise and Fluid Replacement
(2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802ca597 · Cited by 1,497
Nutrition and Athletic Performance
(2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000852 · Cited by 1,305
Cited by
Physiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
Self-citationSkin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
“1989), very few recent reviews have provided an update on mechanisms underlying sweat composition in the context of sweat as a potential biomarker of human health (Baker 2019).”
BackgroundMethodResultInfluentialSelf-citationMiao, D., Cheng, N., Wang, X., Yu, J., & Ding, B. (2022) · Nano Letters · doi:10.1021/acs.nanolett.1c03801 · Cited by 256
Ardalan, S., Hosseinifard, M., Vosough, M., & Golmohammadi, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112450 · Cited by 195
Metadata
- Authors
- Baker, L. B., De Chavez, P. J. D., Ungaro, C. T., Sopeña, B. C., Nuccio, R. P., Reimel, A. J., & Barnes, K. A.
- Venue
- European Journal of Applied Physiology
- Published
- 2018-12-06
- Volume
- 119
- Issue
- 2
- Pages
- 361-375
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2905128970
- Cited by
- 110
- References
- 62
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.