Laparoscopic evaluation of intestinal ischemia using fluorescein and ultraviolet light in a porcine model
The DOI matches its Crossref record; 20 of the 21 references it cites were found in a registry or an index.
Abstract
Background The laparoscopic use of fluorescein and ultraviolet light may be a useful diagnostic tool that potentially could reduce the time until diagnosis and the subsequent mortality of mesenteric ischemia.Methods Eight pigs were subjected to a pneumoperitoneum pressure of 7 mmHg, and another eight pigs were exposed to a pressure of 14 mmHg. A segment of small bowel was devascularized. Two filters were used to create ultraviolet light. Pigs from each pressure group were given various intravenous fluorescein doses. The ischemic segment of the small intestine and other structures were inspected laparoscopically with the filters attached. A videotape was evaluated by resident and attending surgeons.Results Ischemic bowel was seen as a darkened silhouette against the viable fluorescent tissue. Overall, the results show that the use of ultraviolet light and fluorescence in the laparoscopic model is adequate for allowing the identification of ischemic bowel.Conclusions The laparoscopic use of ultraviolet light combined with intravenous fluorescein dye is an effective diagnostic tool for evaluating mesenteric ischemia in pigs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Flowmetry with fluorescein dye is currently part of the accepted standard of clinical care for intraoperative assessment of bowel viability.”
From Acute mesenteric ischemia: updated guidelines of the World Society of Emergency Surgery. (2022) · cites this paper as [89]
Citations
Cites
BULKLEY, G. B., ZUIDEMA, G. D., HAMILTON, S. R., OʼMARA, C. S., KLACSMANN, P. G., & HORN, S. D. (1981) · Annals of Surgery · doi:10.1097/00000658-198105000-00014 · Cited by 203
Failure to improve outcome in acute mesenteric ischaemia: seven-year review
Mamode, I. P. (1999) · The European Journal of Surgery · doi:10.1080/110241599750007054 · Cited by 154
Diagnostic Tests for Intestinal Ischemia
Kurland, B., Brandt, L. J., & Delany, H. M. (1992) · Surgical Clinics of North America · doi:10.1016/s0039-6109(16)45629-x · Cited by 119 · cited 7×
“However, administration of intravenous contrast and transport of the patient to the radiology department are required for this procedure and pose potential risks to medically unstable patients [9, 11].”
BackgroundMethodInfluentialOperative Assessment of Intestinal Viability
Horgan, P. G., & Gorey, T. F. (1992) · Surgical Clinics of North America · doi:10.1016/s0039-6109(16)45632-x · Cited by 117 · cited 4×
“Fluorescein dye is inexpensive, readily available, and safe [2, 5, 7, 11, 12, 18].”
BackgroundMethodInfluentialThe Use of Fluorescein to Determine the Adequacy of the Circulation
Lange, K., & Boyd, L. J. (1942) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)36467-7 · Cited by 102 · cited 3×
“of viable, perfused tissue when it is exposed to long wave ultraviolet light [12].”
BackgroundMethodAcute mesenteric ischemia: an aggressive diagnostic and therapeutic approach. 1991 Roussel Lecture.
Kaleya, R. N., & Boley, S. J. (1992) · PubMed · Cited by 63
(1993) · PubMed · Cited by 61
Laparoscopy in the critically ill
Orlando, R., & Crowell, K. L. (1997) · Surgical Endoscopy · doi:10.1007/s004649900532 · Cited by 52
Mann, A., Fazio, V. W., & Lucas, F. V. (1982) · PubMed · Cited by 49
Iberti, T. J., SALKY, B. A., & Onofrey, D. (1989) · PubMed · Cited by 48
Evaluation of ischemic bowel viability with a fluorescent technique
Stolar, C. J. H., & Randolph, J. G. (1978) · Journal of Pediatric Surgery · doi:10.1016/s0022-3468(78)80390-x · Cited by 38 · cited 2×
“Fluorescein dye is inexpensive, readily available, and safe [2, 5, 7, 11, 12, 18].”
BackgroundMethodDiagnostic laparoscopy in mesenteric ischemia
Zamir, G. A., & Reissman, P. (1998) · Surgical Endoscopy · doi:10.1007/s004649900688 · Cited by 36 · cited 1×
“Diagnostic laparoscopy for the evaluation of abdominal vascular catastrophes is not yet an established method, but is being used increasingly to assess the acute abdomen at the bedside [8, 15, 20].”
MethodThe Use of Infrared Photoplethysmography in Identifying Early Intestinal Ischemia
Pearce, W. H. (1987) · Archives of Surgery · doi:10.1001/archsurg.1987.01400150062012 · Cited by 35 · cited 1×
“[17] found similar results in the early assessment of intestinal ischemia in the canine model with a sensitivity of 88%.”
ResultABDOMINAL VASCULAR CATASTROPHES
Eldrup-Jørgensen, J., Hawkins, R. E., & Bredenberg, C. E. (1997) · Surgical Clinics of North America · doi:10.1016/s0039-6109(05)70619-8 · Cited by 35 · cited 2×
“Delayed diagnosis is cited as an important factor contributing to poor outcome, yet early diagnosis of intestinal ischemia remains one of the most challenging aspects of the disease [1, 4, 8, 11, 13].”
BackgroundIntraoperative Evaluation of Intestinal Ischemia
Dyess, D. L., BRUNER, B. W., Donnell, C. A., Ferrara, J. J., & Powell, R. W. (1991) · Southern Medical Journal · doi:10.1097/00007611-199108000-00008 · Cited by 31 · cited 2×
“The use of intravenous sodium fluorescein with ultraviolet light to produce fluorescence in tissue is an established technique to determine intraoperative intestinal viability [1–3, 5–7, 10–12, 14, 18].”
BackgroundMethod[Mesenterial infarct. New aspects of diagnosis and therapy].
Paes, E. H. J., Jf, V., Hutschenreiter, S., Mh, S., Kübel, R., & Schölzel, E. (1988) · PubMed · Cited by 27
The recovery of intestine after ischaemic injury
GOREY, T. F. (1980) · British journal of surgery · doi:10.1002/bjs.1800671006 · Cited by 25 · cited 2×
“Gorey [ 6 ] reported a sensitivity of 96% and a specificity of 95% with the use of fluorescein fluorescence in open exploration for mesenteric ischemia in the rat model.”
BackgroundMethodFluorescein endoscopy: A technique for noninvasive assessment of intestinal ischemia
Galandiuk, S., Fazio, V. W., & Petras, R. E. (1988) · Diseases of the Colon & Rectum · doi:10.1007/bf02554847 · Cited by 18
Splanchnic mucosal ischemia: an unrecognized consequence of routine pneumoperitoneum.
Ma, W., Bonham, M. J. D., & Rumball, M. (1997) · PubMed · Cited by 18
Fluorescein-assisted laparoscopy in the identification of arterial mesenteric ischemia
Kam, D., & Scheeres, D. E. (1993) · Surgical Endoscopy · doi:10.1007/bf00704381 · Cited by 16 · cited 2×
“The adjuvant use of fluorescein dye has been shown to increase the sensitivity and specificity of clinical judgement alone in open laparotomies for intestinal ischemia, and it is more accurate than other operative means of diagnosis, such as Doppler flowmetry [1, 2, 6, 7, 10 , 14].”
BackgroundMethod
Research works printed but not linked: 6
- J Ballard, 1993, Am Surg, 59, 309
- T Iberti, 1989, Surgery, 105, 686
- R Kaleya, 1992, Can J Surg, 35, 613
- A Mann, 1982, Surg Gynecol Obstet, 154, 53
- E Paes, 1988, Chirurg, 59, 828
- J Windsor, 1997, Surg Laparosc Endosc, 7, 480, 10.1097/00019509-199712000-00010 · doi:10.1097/00019509-199712000-00010
Cited by
Acute mesenteric ischemia: updated guidelines of the World Society of Emergency Surgery.
Bala, M., Catena, F., Kashuk, J., De Simone, B., Gomes, C. A., Weber, D., Sartelli, M., Coccolini, F., Kluger, Y., Abu-Zidan, F. M., et al. (2022) · World Journal of Emergency Surgery · doi:10.1186/s13017-022-00443-x · Cited by 380
“Fluorescein can therefore be used to visualize perfusion in open laparotomies using a Woods Lamp or laparoscopically using an endoscope with appropriate filters [88, 89].”
MethodAcute Mesenteric Ischemia: Diagnostic Approach and Surgical Treatment
Wyers, M. C. (2010) · Seminars in Vascular Surgery · doi:10.1053/j.semvascsurg.2009.12.002 · Cited by 259
Garland, M., Yim, J. J., & Bogyo, M. (2016) · Cell Chemical Biology · doi:10.1016/j.chembiol.2015.12.003 · Cited by 254
“Thus, all of the current clinical work makes use of non-targeted dyes such as indocyanine green (ICG) (Buchs et al., 2012; Verbeek et al., 2014a; Yoshida et al., 2012), methylene blue (MB) (Tummers et al., 2015; Verbeek et al., 2013), and fluorescein (Gribar and Hamad, 2007; McGinty et al., 2003).”
How to assess intestinal viability during surgery: A review of techniques
Urbanavičius, L. (2011) · World Journal of Gastrointestinal Surgery · doi:10.4240/wjgs.v3.i5.59 · Cited by 235
Current Management of Small Bowel Obstruction
Zielinski, M. D., & Bannon, M. P. (2011) · Advances in Surgery · doi:10.1016/j.yasu.2011.03.017 · Cited by 119
“Laparoscopic fluorescein dye techniques have been developed, but not studied in humans [88–90].”
Background
Metadata
- Authors
- McGinty, J. J., Hogle, N., & Fowler, D. L.
- Affiliations
- Allegheny Health Network (US)
- NewYork–Presbyterian Hospital (US)
- Venue
- Surgical Endoscopy And Other Interventional Techniques
- Published
- 2003-04-28
- Volume
- 17
- Issue
- 7
- Pages
- 1140-1143
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W2092517474
- Cited by
- 18
- References
- 21
- Citations by year
- 2025: 2 · 2022: 2 · 2020: 2 · 2016: 1 · 2015: 1 · 2014: 1 · 2012: 1
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Surgical Endoscopy (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Abdominal vascular conditions and treatments
- Health Sciences › Medicine › Gastroenterology › Gastrointestinal Bleeding Diagnosis and Treatment
- Health Sciences › Medicine › Emergency Medicine › Appendicitis Diagnosis and Management
- Keywords
- mesenteric ischemia, intestinal ischemia, diagnostic laparoscopy, fluorescein, ultraviolet radiation, porcine model, pneumoperitoneum, fluorescence imaging
- MeSH terms
- Animals, Disease Models, Animal, Intestines, Ischemia, Laparoscopy, Swine, Ultraviolet Rays, Fluorescein
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.