Clinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgery
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Recently major developments in video imaging have been achieved: among these, the use of high definition and 3D imaging systems, and more recently indocyanine green (ICG) fluorescence imaging are emerging as major contributions to intraoperative decision making during surgical procedures. The aim of this study was to present our experience with different laparoscopic procedures using ICG fluorescence imaging. PATIENTS AND METHODS: 108 ICG-enhanced fluorescence-guided laparoscopic procedures were performed: 52 laparoscopic cholecystectomies, 38 colorectal resections, 8 living-donor nephrectomies, 1 laparoscopic kidney autotransplantation, 3 inguino-iliac/obturator lymph node dissections for melanoma, and 6 miscellanea procedures. Visualization of structures was provided by a high definition stereoscopic camera connected to a 30° 10 mm scope equipped with a specific lens and light source emitting both visible and near infra-red (NIR) light (KARL STORZ GmbH & Co. KG, Tuttlingen, Germany). After injection of ICG, the system projected high-resolution NIR real-time images of blood flow in vessels and organs as well as highlighted biliary excretion . RESULTS: No intraoperataive or injection-related adverse effects were reported, and the biliary/vascular anatomy was always clearly identified. The imaging system provided invaluable information to conduct a safe cholecystectomy and ensure adequate vascular supply for colectomy, nephrectomy, or find lymph nodes. There were no bile duct injuries or anastomotic leaks. CONCLUSIONS: In our experience, the ICG fluorescence imaging system seems to be simple, safe, and useful. The technique may well become a standard in the near future in view of its different diagnostic and oncological capabilities. Larger studies and more specific evaluations are needed to confirm its role and to address its disadvantages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of NIR dyes in cancer targeting and imaging
Luo, S., Zhang, E., Su, Y., Cheng, T., & Shi, C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.024 · Cited by 1,432
A Review of Indocyanine Green Fluorescent Imaging in Surgery
Alander, J. T., Kaartinen, I., Laakso, A., Pätilä, T., Spillmann, T., Tuchin, V. V., Venermo, M., & Välisuo, P. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/940585 · Cited by 1,352
Real‐time identification of liver cancers by using indocyanine green fluorescent imaging
Ishizawa, T., Fukushima, N., Shibahara, J., Masuda, K., Tamura, S., Aoki, T., Hasegawa, K., Beck, Y., Fukayama, M., & Kokudo, N. (2009) · Cancer · doi:10.1002/cncr.24291 · Cited by 852
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Tornqvist, B., Stromberg, C., Persson, G., & Nilsson, M. (2012) · BMJ · doi:10.1136/bmj.e6457 · Cited by 535
Intraoperative Cholangiography and Risk of Common Bile Duct Injury During Cholecystectomy
Flum, D. R., Dellinger, E. P., Cheadle, A., Chan, L., & Koepsell, T. (2003) · JAMA · doi:10.1001/jama.289.13.1639 · Cited by 491
Fluorescent cholangiography illuminating the biliary tree during laparoscopic cholecystectomy
Ishizawa, T., Bandai, Y., Ijichi, M., Kaneko, J., Hasegawa, K., & Kokudo, N. (2010) · British Journal of Surgery · doi:10.1002/bjs.7125 · Cited by 381
Jafari, M. D., Lee, K. H., Halabi, W. J., Mills, S. D., Carmichael, J. C., Stamos, M. J., & Pigazzi, A. (2013) · Surgical Endoscopy · doi:10.1007/s00464-013-2832-8 · Cited by 337
Kudszus, S., Roesel, C., Schachtrupp, A., & Höer, J. J. (2010) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-010-0699-x · Cited by 334
Kusano, M., Tajima, Y., Yamazaki, K., Kato, M., Watanabe, M., & Miwa, M. (2008) · Digestive Surgery · doi:10.1159/000121905 · Cited by 315
Cited by
Nagaya, T., Nakamura, Y. A., Choyke, P. L., & Kobayashi, H. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00314 · Cited by 398
Indocyanine green-incorporating nanoparticles for cancer theranostics
Wang, H., Li, X., Tse, B. W.-C., Yang, H., Thorling, C. A., Liu, Y., Touraud, M., Chouane, J. B., Liu, X., Roberts, M. S., et al. (2018) · Theranostics · doi:10.7150/thno.22872 · Cited by 378
van Manen, L., Handgraaf, H. J. M., Diana, M., Dijkstra, J., Ishizawa, T., Vahrmeijer, A. L., & Mieog, J. S. D. (2018) · Journal of Surgical Oncology · doi:10.1002/jso.25105 · Cited by 322
Zhang, S., Guo, W., Wei, J., Li, C., Liang, X.-J., & Yin, M. (2017) · ACS Nano · doi:10.1021/acsnano.6b08720 · Cited by 284
In vivo fluorescence imaging: success in preclinical imaging paves the way for clinical applications
Refaat, A., Yap, M. L., Pietersz, G., Walsh, A. P. G., Zeller, J., del Rosal, B., Wang, X., & Peter, K. (2022) · Journal of Nanobiotechnology · doi:10.1186/s12951-022-01648-7 · Cited by 266
Indocyanine green delivery systems for tumour detection and treatments
Porcu, E. P., Salis, A., Gavini, E., Rassu, G., Maestri, M., & Giunchedi, P. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.04.001 · Cited by 212
Degett, T. H., Andersen, H. S., & Gögenur, I. (2016) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-016-1400-9 · Cited by 208
“surgery, and patients duplicates in two studies by the same author [31, 32].”
BackgroundBoni, L., Fingerhut, A., Marzorati, A., Rausei, S., Dionigi, G., & Cassinotti, E. (2017) · Surgical Endoscopy · doi:10.1007/s00464-016-5181-6 · Cited by 193
Self-citationYang, Z., Wang, J., Liu, S., Li, X., Miao, L., Yang, B., Zhang, C., He, J., Ai, S., & Guan, W. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119580 · Cited by 165
Chen, M., Feng, Z., Fan, X., Sun, J., Geng, W., Wu, T., Sheng, J., Qian, J., & Xu, Z. (2022) · Nature Communications · doi:10.1038/s41467-022-34274-w · Cited by 57
Liot, E., Assalino, M., Buchs, N. C., Schiltz, B., Douissard, J., Morel, P., & Ris, F. (2018) · Surgical Endoscopy · doi:10.1007/s00464-018-6226-9 · Cited by 48
“This technology requires a special endoscope emitting a signal at a wavelength of 805 nm to visualize the blood flow in vessels and organs [4, 5].”
Metadata
- Authors
- Boni, L., David, G., Mangano, A., Dionigi, G., Rausei, S., Spampatti, S., Cassinotti, E., & Fingerhut, A.
- Venue
- Surgical Endoscopy
- Published
- 2014-10-11
- Volume
- 29
- Issue
- 7
- Pages
- 2046-2055
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W1998588165
- Cited by
- 548
- References
- 35
- FWCI
- 17.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.