Comparison of titanium and polyetheretherketone (PEEK) cages in the surgical treatment of multilevel cervical spondylotic myelopathy: a prospective, randomized, control study with over 7-year follow-up
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morbidity at Bone Graft Donor Sites
Younger, E. M., & Chapman, M. W. (1989) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-198909000-00002 · Cited by 2,012
The Anterior Approach for Removal of Ruptured Cervical Disks
Cloward, R. B. (1958) · Journal of Neurosurgery · doi:10.3171/jns.1958.15.6.0602 · Cited by 1,778 · cited 1×
“Since Cloward [11] and Smith and Robinson [27] described anterior cervical discectomy and fusion (ACDF), it has been widely used as an ideal surgical treatment method for cervical disc degenerative disorders.”
Arthrodesis by the Distraction-Compression Method Using a Stainless Steel Implant
Bagby, G. W. (1988) · Orthopedics · doi:10.3928/0147-7447-19880601-13 · Cited by 369 · cited 1×
“The use of stand-alone cage technology in cervical spondylosis was first introduced by Bagby [1].”
Niu, C.-C., Liao, J.-C., Chen, W.-J., & Chen, L.-H. (2010) · Journal of Spinal Disorders & Techniques · doi:10.1097/bsd.0b013e3181af3a84 · Cited by 180 · cited 4×
“Recently, two studies compared clinical and radiological results of titanium and PEEK cages, but discrepant results were reported [6, 24].”
InfluentialA Meta-Analysis of Comparative Outcomes Following Cervical Arthroplasty or Anterior Cervical Fusion
McAfee, P. C., Reah, C., Gilder, K. M., Eisermann, L., & Cunningham, B. W. (2011) · Spine · doi:10.1097/brs.0b013e31823da169 · Cited by 113
Thom�, C., Krauss, J. K., & Zevgaridis, D. (2004) · Neurosurgical Review · doi:10.1007/s10143-003-0297-2 · Cited by 110
Cited by
Polyetheretherketone (PEEK) for medical applications
Panayotov, I. V., Orti, V., Cuisinier, F., & Yachouh, J. (2016) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-016-5731-4 · Cited by 603
Seaman, S., Kerezoudis, P., Bydon, M., Torner, J. C., & Hitchon, P. W. (2017) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2017.06.062 · Cited by 294
Yuan, B., Cheng, Q., Zhao, R., Zhu, X., Yang, X., Yang, X., Zhang, K., Song, Y., & Zhang, X. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.014 · Cited by 204
Evaniew, N., Files, C., Smith, C., Bhandari, M., Ghert, M., Walsh, M., Devereaux, P. J., & Guyatt, G. (2015) · The Spine Journal · doi:10.1016/j.spinee.2015.06.004 · Cited by 187
“[45] 2013 Titanium versus polyetheretherketone cages in cervical spondylotic myelopathy Outcome of ‘‘excellent or good’’ 80 39 0”
Muthu, S., & Ramakrishnan, E. (2021) · Spine · doi:10.1097/brs.0000000000003645 · Cited by 30
Metadata
- Authors
- Chen, Y., Wang, X., Lu, X., Yang, L., Yang, H., Yuan, W., & Chen, D.
- Venue
- European Spine Journal
- Published
- 2013-04-09
- Volume
- 22
- Issue
- 7
- Pages
- 1539-1546
- ISSN
- 0940-6719 (ISSN-L)
- 1432-0932
- OpenAlex
- W1988489273
- Cited by
- 197
- References
- 6
- FWCI
- 11.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.