The DOI matches its Crossref record.
Outcomes of Interbody Fusion Cages Used in 1 and 2-levels Anterior Cervical Discectomy and Fusion: Titanium Cages Versus Polyetheretherketone (PEEK) Cages
Abstract
STUDY DESIGN: A prospective study was performed in case with cervical spondylosis who underwent anterior cervical discectomy and fusion (ACDF) with titanium or polyetheretherketone (PEEK) cages. OBJECTIVE: To find out which fusion cage yielded better clinical and radiographic results. SUMMARY OF BACKGROUND DATA: Although use of autogenous iliac-bone grafts in ACDF for cervical disc diseases remain standard surgical procedure, donor site morbidity and graft collapse or breakage are concerns. Cage technology was developed to prevent these complications. However, there is no comparison regarding the efficacy between titanium and PEEK cage. METHODS: January 2005 to January 2006, 53 patients who had 1 and 2-levels ACDF with titanium or PEEK cages were evaluated. We measured the rate and amount of interspace collapse, segmental sagittal angulations, and the radiographic fusion success rate. Odom criteria were used to assess the clinical results. RESULTS: The fusion rate was higher in the PEEK group (100% vs. 86.5%, P=0.0335). There was no significant difference between both groups in loss of cervical lordosis (3.2 + or - 2.4 vs. 2.8 + or - 3.4, P=0.166). The mean anterior interspace collapse (1.6 + or - 1.0 mm) in the titanium group was significantly higher than the collapse of the PEEK group (0.5 + or - 0.6 mm) (P<0.0001). The mean posterior interspace collapse was also higher in the titanium group (1.6 + or - 0.9 mm vs. 0.5 + or - 0.5 mm, P<0.0001). An interspace collapse of 3 mm or greater was observed in 16.2% of the patients in the titanium group, compared with zero patients in the PEEK group (P<0.0001). The PEEK group achieved an 80% rate of successful clinical outcomes, compared with 75% in the titanium group (P=0.6642). CONCLUSIONS: The PEEK cage is superior to the titanium cage in maintaining cervical interspace height and radiographic fusion after 1 and 2-levels anterior cervical decompression procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Seaman, S., Kerezoudis, P., Bydon, M., Torner, J. C., & Hitchon, P. W. (2017) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2017.06.062 · Cited by 294
Rao, P. J., Pelletier, M. H., Walsh, W. R., & Mobbs, R. J. (2014) · Orthopaedic Surgery · doi:10.1111/os.12098 · Cited by 285
McGilvray, K. C., Easley, J., Seim, H. B., Regan, D., Berven, S. H., Hsu, W. K., Mroz, T. E., & Puttlitz, C. M. (2018) · The Spine Journal · doi:10.1016/j.spinee.2018.02.018 · Cited by 256
Yuan, B., Cheng, Q., Zhao, R., Zhu, X., Yang, X., Yang, X., Zhang, K., Song, Y., & Zhang, X. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.014 · Cited by 204
Metadata
- Authors
- Niu, C.-C., Liao, J.-C., Chen, W.-J., & Chen, L.-H.
- Venue
- Journal of Spinal Disorders & Techniques
- Published
- 2010-07
- Volume
- 23
- Issue
- 5
- Pages
- 310-316
- ISSN
- 1536-0652 (ISSN-L)
- OpenAlex
- W1974559847
- Cited by
- 180
- References
- 0
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outcomes of Interbody Fusion Cages Used in 1 and 2-levels Anterior Cervical Discectomy and Fusion: Titanium Cages Versus Polyetheretherketone (PEEK) Cages. https://app.cochat.ai/papers/10.1097/bsd.0b013e3181af3a84
- The paper
- Niu, C.-C., Liao, J.-C., Chen, W.-J., & Chen, L.-H. (2010). Outcomes of Interbody Fusion Cages Used in 1 and 2-levels Anterior Cervical Discectomy and Fusion: Titanium Cages Versus Polyetheretherketone (PEEK) Cages. Journal of Spinal Disorders & Techniques. https://doi.org/10.1097/bsd.0b013e3181af3a84
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.