CoChat

High-abundance proteins depletion for serum proteomic analysis: concomitant removal of non-targeted proteins

Open access
Bellei, Elisa, Bergamini, Stefania, Monari, Emanuela, Fantoni, Luca Isaia, Cuoghi, Aurora, Ozben, Tomris, Tomasi, Aldo · 2011 · Amino Acids
Cited by 183

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

In clinical and pharmaceutical proteomics, serum and plasma are frequently used for detection of early diagnostic biomarkers for therapeutic targets. Although obtaining these body fluid samples is non-invasive and easy, they contain some abundant proteins that mask other protein components present at low concentrations. The challenge in identifying serum biomarkers is to remove the abundant proteins, uncovering and enriching at the same time the low-abundance ones. The depletion strategies, however, could lead to the concomitant removal of some non-targeted proteins that may be of potential interest. In this study, we compared three different methods aimed to deplete high-abundance proteins from human serum, focusing on the identification of non-specifically bound proteins which might be eventually removed. A Cibacron blue-dye-based method for albumin removal, an albumin and IgG immunodepletion method and an immunoaffinity column (Multiple Affinity Removal System) that simultaneously removes a total of six high-abundance proteins, were investigated. The bound proteins were eluted, separated by two-dimensional gel electrophoresis and identified by Nano LC-CHIP-MS system. Flow-through fractions and bound fractions were also analysed with the ProteinChip technology SELDI-TOF-MS. Our results showed that the methods tested removed not only the targeted proteins with high efficiency, but also some non-targeted proteins. We found that the Multiple Affinity Removal Column improved the intensity of low-abundance proteins, displayed new protein spots and increased resolution. Notably, the column showed the lowest removal of untargeted proteins, proved to be the most promising depletion approach and a reliable method for serum preparation prior to proteomic studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00726-010-0628-x

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 183

Metadata

Authors
Bellei, E., Bergamini, S., Monari, E., Fantoni, L. I., Cuoghi, A., Ozben, T., & Tomasi, A.
Venue
Amino Acids
Published
2010-05-22
Volume
40
Issue
1
Pages
145-156
ISSN
  • 0939-4451 (ISSN-L)
  • 1438-2199
OpenAlex
W2168193025
Cited by
183
References
35
FWCI
6.22
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.