Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Open accessThe DOI matches its Crossref record; 109 of the 109 references it cites were found in a registry or an index.
Abstract
This article reviews state-of-the-art microfluidic biosensors of nucleic acids and proteins for point-of-care (POC) diagnostics. Microfluidics is capable of analyzing small sample volumes (10−9–10−18 l) and minimizing costly reagent consumption as well as automating sample preparation and reducing processing time. The merger of microfluidics and advanced biosensor technologies offers new promises for POC diagnostics, including high-throughput analysis, portability and disposability. However, this merger also imposes technological challenges on biosensors, such as high sensitivity and selectivity requirements with sample volumes orders of magnitude smaller than those of conventional practices, false response errors due to non-specific adsorption, and integrability with other necessary modules. There have been many prior review articles on microfluidic-based biosensors, and this review focuses on the recent progress in last 5 years. Herein, we review general technologies of DNA and protein biosensors. Then, recent advances on the coupling of the biosensors to microfluidics are highlighted. Finally, we discuss the key challenges and potential solutions for transforming microfluidic biosensors into POC diagnostic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Carbon‐Nanotube Based Electrochemical Biosensors: A Review
Wang, J. (2005) · Electroanalysis · doi:10.1002/elan.200403113 · Cited by 2,387
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Enzyme Immunoassay (EIA)/Enzyme-Linked Immunosorbent Assay (ELISA)
Lequin, R. M. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051532 · Cited by 1,548
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Paleček, E., Tkáč, J., Bartošík, M., Bertók, T., Ostatná, V., & Paleček, J. (2015) · Chemical Reviews · doi:10.1021/cr500279h · Cited by 319
Non-Specific Adsorption Reduction Methods in Biosensing
Lichtenberg, J. Y., Ling, Y., & Kim, S. (2019) · Sensors · doi:10.3390/s19112488 · Cited by 296
Advancements in microfluidics for nanoparticle separation
Salafi, T., Zeming, K. K., & Zhang, Y. (2017) · Lab on a Chip · doi:10.1039/c6lc01045h · Cited by 261
Leng, Y., Sun, K., Chen, X., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00382a · Cited by 258
Porous Silicon-Based Photonic Biosensors: Current Status and Emerging Applications
Arshavsky-Graham, S., Massad-Ivanir, N., Segal, E., & Weiss, S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05028 · Cited by 205
Biosensors for rapid detection of Salmonella in food: A review
Shen, Y., Xu, L., & Li, Y. (2021) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12662 · Cited by 201
New analytical applications of gold nanoparticles as label in antibody based sensors
Omidfar, K., Khorsand, F., & Darziani Azizi, M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.12.045 · Cited by 200
“The regular assessment of analytes in biological specimens is required to demonstrate the metabolic states of patients, particularly for those who have been admitted to intensive care (Choi et al., 2011; Omidfar et al., 2012a).”
BackgroundSoler, M., Estevez, M. C., Cardenosa-Rubio, M., Astua, A., & Lechuga, L. M. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01180 · Cited by 189
A low-cost miniaturized potentiostat for point-of-care diagnosis
Cruz, A. F. D., Norena, N., Kaushik, A., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.053 · Cited by 165
“…physiological variables at pointof-care (POC) can be useful to personalize health diagnostics for appropriate effectual treatment (Ahn et al., 2004; Choi et al., 2011; Gubala et al., 2011; Justino et al., 2013; Kaushik et al., 2014; Kemmler et al., 2014; Kost, 1995; Kumar et al., 2013; Loncaric et…”
BackgroundKaur, G., Tomar, M., & Gupta, V. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.144 · Cited by 105
Metadata
- Authors
- Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J.
- Venue
- Microfluidics and Nanofluidics
- Published
- 2010-06-02
- Volume
- 10
- Issue
- 2
- Pages
- 231-247
- ISSN
- 1613-4982 (ISSN-L)
- 1613-4990
- OpenAlex
- W2094588486
- Cited by
- 270
- References
- 109
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.