Laser Speckle Contrast Imaging of Cerebral Blood Flow
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Laser speckle contrast imaging (LSCI) has emerged over the past decade as a powerful, yet simple, method for imaging of blood flow dynamics in real time. The rapid adoption of LSCI for physiological studies is due to the relative ease and low cost of building an instrument as well as the ability to quantify blood flow changes with excellent spatial and temporal resolution. Although measurements are limited to superficial tissues with no depth resolution, LSCI has been instrumental in pre-clinical studies of neurological disorders as well as clinical applications including dermatological, neurosurgical and endoscopic studies. Recently a number of technical advances have been developed to improve the quantitative accuracy and temporal resolution of speckle imaging. This article reviews some of these recent advances and describes several applications of speckle imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pathobiology of ischaemic stroke: an integrated view
Dirnagl, U., Iadecola, C., & Moskowitz, M. A. (1999) · Trends in Neurosciences · doi:10.1016/s0166-2236(99)01401-0 · Cited by 3,943
Mechanisms, challenges and opportunities in stroke
Lo, E. H., Dalkara, T., & Moskowitz, M. A. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1106 · Cited by 1,781
Helmlinger, G., Yuan, F., Dellian, M., & Jain, R. K. (1997) · Nature Medicine · doi:10.1038/nm0297-177 · Cited by 1,628
Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model
Bolay, H., Reuter, U., Dunn, A. K., Huang, Z., Boas, D. A., & Moskowitz, M. A. (2002) · Nature Medicine · doi:10.1038/nm0202-136 · Cited by 1,214
Self-citationLaser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Self-citationModel for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle
Dunn, A. K., Bolay, H., Moskowitz, M. A., & Boas, D. A. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200103000-00002 · Cited by 826
Self-citationLaser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686
Briers, J. D. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231359 · Cited by 686
Flow visualization by means of single-exposure speckle photography
Fercher, A. F., & Briers, J. D. (1981) · Optics Communications · doi:10.1016/0030-4018(81)90428-4 · Cited by 670
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Imaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue
Rumsey, W., Vanderkooi, J., & Wilson, D. (1988) · Science · doi:10.1126/science.241.4873.1649 · Cited by 534
Oxygen Gradients in the Microcirculation
TSAI, A. G., JOHNSON, P. C., & INTAGLIETTA, M. (2003) · Physiological Reviews · doi:10.1152/physrev.00034.2002 · Cited by 450
Correlation between periinfarct DC shifts and ischaemic neuronal damage in rat
Mies, G., lijima, T., & Hossmann, K.-A. (1993) · NeuroReport · doi:10.1097/00001756-199306000-00027 · Cited by 404
Robust flow measurement with multi-exposure speckle imaging
Parthasarathy, A. B., Tom, W. J., Gopal, A., Zhang, X., & Dunn, A. K. (2008) · Optics Express · doi:10.1364/oe.16.001975 · Cited by 367
Self-citationDunn, A. K., Devor, A., Bolay, H., Andermann, M. L., Moskowitz, M. A., Dale, A. M., & Boas, D. A. (2003) · Optics Letters · doi:10.1364/ol.28.000028 · Cited by 333
Self-citationVasoconstrictive Neurovascular Coupling during Focal Ischemic Depolarizations
Shin, H. K., Dunn, A. K., Jones, P. B., Boas, D. A., Moskowitz, M. A., & Ayata, C. (2006) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600252 · Cited by 320
Self-citationOxyphor R2 and G2: phosphors for measuring oxygen by oxygen-dependent quenching of phosphorescence
Dunphy, I., Vinogradov, S. A., & Wilson, D. F. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00384-6 · Cited by 288
Dunn, A. K., Devor, A., Dale, A. M., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.024 · Cited by 285
Self-citationAyata, C., Dunn, A. K., Gursoy-Özdemir, Y., Huang, Z., Boas, D. A., & Moskowitz, M. A. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000122745.72175.d5 · Cited by 276
Self-citation(1996) · PubMed · Cited by 223
Yuan, S., Devor, A., Boas, D. A., et al. (2005) · Applied Optics · doi:10.1364/ao.44.001823 · Cited by 222
Can laser speckle flowmetry be made a quantitative tool?
Duncan, D. D., & Kirkpatrick, S. J. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.002088 · Cited by 219
Spreading depolarizations cycle around and enlarge focal ischaemic brain lesions
Nakamura, H., Strong, A. J., Dohmen, C., Sakowitz, O. W., Vollmar, S., Sué, M., Kracht, L., Hashemi, P., Bhatia, R., Yoshimine, T., et al. (2010) · Brain · doi:10.1093/brain/awq117 · Cited by 212
Self-citationDurduran, T., Burnett, M. G., Yu, G., Zhou, C., Furuya, D., Yodh, A. G., Detre, J. A., & Greenberg, J. H. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200405000-00005 · Cited by 168
Shin, H. K., Dunn, A. K., Jones, P. B., Boas, D. A., Lo, E. H., Moskowitz, M. A., & Ayata, C. (2007) · Brain · doi:10.1093/brain/awm071 · Cited by 163
Self-citationJones, P., Shin, H. K., Boas, D. A., Hyman, B. T., Moskowitz, M. A., Ayata, C., & Dunn, A. K. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2950312 · Cited by 134
Self-citationIntraoperative monitoring of cerebral blood flow by laser speckle contrast analysis
Hecht, N., Woitzik, J., Dreier, J. P., & Vajkoczy, P. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.8.focus09148 · Cited by 123
Parthasarathy, A. B., Kazmi, S. M. S., & Dunn, A. K. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000246 · Cited by 117
Self-citationShonat, R. D., Wachman, E. S., Niu, W., Koretsky, A. P., & Farkas, D. L. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78155-4 · Cited by 116
Vinogradov, S. A., Fernández‐Seara, M. A., Dugan, B. W., & Wilson, D. F. (2001) · Review of Scientific Instruments · doi:10.1063/1.1386634 · Cited by 114
Shonat, R. D., Wilson, D. F., Riva, C. E., & Pawlowski, M. (1992) · Applied Optics · doi:10.1364/ao.31.003711 · Cited by 111
Efficient Processing of Laser Speckle Contrast Images
Tom, W. J., Ponticorvo, A., & Dunn, A. K. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925081 · Cited by 88
Self-citationStrong, A. J., Bezzina, E. L., Anderson, P. J., Boutelle, M. G., Hopwood, S. E., & Dunn, A. K. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600240 · Cited by 86
Self-citationSakadžić, S., Yuan, S., Dileköz, E., Ruvinskaya, S., Vinogradov, S. A., Ayata, C., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d169 · Cited by 69
Shonat, R. D., Richmond, K. N., & Johnson, P. C. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146133 · Cited by 39
Simultaneous imaging of oxygen tension and blood flow in animals using a digital micromirror device
Ponticorvo, A., & Dunn, A. K. (2010) · Optics Express · doi:10.1364/oe.18.008160 · Cited by 29
Self-citation
Cited by
Through-skull fluorescence imaging of the brain in a new near-infrared window
Hong, G., Diao, S., Chang, J., Antaris, A. L., Chen, C., Zhang, B., Zhao, S., Atochin, D. N., Huang, P. L., Andreasson, K. I., et al. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.166 · Cited by 1,061
Microglia modulate blood flow, neurovascular coupling, and hypoperfusion via purinergic actions
Császár, E., Lénárt, N., Cserép, C., Környei, Z., Fekete, R., Pósfai, B., Balázsfi, D., Hangya, B., Schwarcz, A. D., Szabadits, E., et al. (2022) · Journal of Experimental Medicine · doi:10.1084/jem.20211071 · Cited by 263
Microvascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
“Dunn (2012) has reviewed LSCI and its application to stroke research and intra-operative real-time monitoring of human brain blood flow in neurosurgery.”
BackgroundSystems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
Metadata
- Authors
- Dunn, A. K.
- Venue
- Annals of Biomedical Engineering
- Published
- 2011-11-23
- Volume
- 40
- Issue
- 2
- Pages
- 367-377
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2067811903
- Cited by
- 278
- References
- 37
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.